# Ohme EV chargers in Peterborough

> Ohme EV charger installation in Peterborough: Home Pro and ePod fitted, load balancing set up, faults traced and chargers moved by Lighting Electrical.

Lighting Electrical fits Ohme Home Pro and ePod chargers in Peterborough, sets the CT clamp on the meter tails and leaves each charger on a tested circuit, paired with the Ohme app.

## Which Ohme chargers do you fit and repair?

We fit and repair Ohme home chargers for electric cars. We also set up the load balancing sensor that comes with them, trace their faults and check them over. Every Ohme goes on its own circuit and is tested before the first charge.
- **Ohme Home Pro and ePod:** The Home Pro is a tethered charger, with the lead fixed to the unit and a small screen on the front. The ePod has a socket and no screen, so you plug in your own Type 2 cable. Both run from their own circuit at the consumer unit, which is the box of breakers where every circuit starts.
- **Load balancing with a CT clamp:** A CT clamp is a sensor clipped round the meter tails that reads how much power the house is drawing. We fit it so the Ohme slows the charge when the cooker, shower and car together would overload the main fuse.
- **Faults we fix on Ohme chargers:** We fix chargers that show offline in the Ohme app, PEN fault warnings, breakers that trip when a charge starts, and damaged leads or connectors. A PEN fault is a break in the combined neutral and earth of the street supply. The Ohme detects it and stops charging. We read the message on the app or screen, then test the supply and the circuit.
- **What servicing an Ohme involves:** Ohme sends firmware updates over the internet, so a service is a hands on check. We look over the lead, the connector and the cable glands for wear or water. We also test the RCBO, which is a breaker with its own earth leakage protection, and confirm the CT clamp reading in the app.

[Ohme's website](https://ohme-ev.com)

## What do you do on an Ohme charger in each service?
- [EICR](https://lightingelectrical.co.uk/services/eicr): from £150
- [Consumer unit replacement](https://lightingelectrical.co.uk/services/fuse-board-replacement): from £450
- [House rewiring](https://lightingelectrical.co.uk/services/house-rewiring): from £2,400
- [Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding): from £75 an hour
- [Lighting installation](https://lightingelectrical.co.uk/services/lighting-installation): from £65
- [Ohme EV charger installation](https://lightingelectrical.co.uk/services/ev-charger-installation): from £750
- [Socket installation](https://lightingelectrical.co.uk/services/sockets-and-switches): from £85
- [Emergency electrician](https://lightingelectrical.co.uk/services/emergency-electrician): from £90 an hour
- [Electrical testing and certificates](https://lightingelectrical.co.uk/services/testing-and-certificates): from £95
- [Smoke alarm installation](https://lightingelectrical.co.uk/services/fire-and-smoke-alarms): from £110
- [Appliance and heating connections](https://lightingelectrical.co.uk/services/appliance-connections): from £120
- [Solar panel and battery storage installation](https://lightingelectrical.co.uk/services/solar-and-battery-storage): from £5,500
- [Forklift charger installation](https://lightingelectrical.co.uk/services/forklift-charger-installation): from £700
- [Commercial Lighting Installation](https://lightingelectrical.co.uk/services/commercial-office-lighting): from £65
- [Starlink installation](https://lightingelectrical.co.uk/services/starlink-installation): from £350
- [Light switch or dimmer replacement](https://lightingelectrical.co.uk/services/light-switch-or-dimmer-replacement): from £60
- [Minor works certificate](https://lightingelectrical.co.uk/services/minor-works-certificate): from £95
- [Extractor fan installation](https://lightingelectrical.co.uk/services/extractor-fan-installation): from £180
- [Electric shower installation](https://lightingelectrical.co.uk/services/electric-shower-installation): from £220
- [Emergency lighting test & certificate](https://lightingelectrical.co.uk/services/emergency-lighting-test-certificate): from £150
- [Immersion heater repair](https://lightingelectrical.co.uk/services/immersion-heater-repair): from £70 an hour
- [Battery storage installation](https://lightingelectrical.co.uk/services/battery-storage-installation): from £4,500
- [Fire alarm system installation](https://lightingelectrical.co.uk/services/fire-alarm-system-installation): from £1,400
- [Cherry picker hire](https://lightingelectrical.co.uk/services/cherry-picker-hire)

## Why is my Ohme charger off when the house has no power?
- **[No power in the whole house](https://lightingelectrical.co.uk/problems/no-power-in-house):** A blank Ohme screen during a whole house outage means the charger has lost power along with everything else. We check the main switch and the RCDs, which cut power when current leaks to earth, and the street supply. We switch the charger circuit on last and confirm it reconnects in the app.

## Ohme charger questions

### Can you install an Ohme Home Pro or ePod?

Yes. We fit both on a dedicated circuit, add a CT clamp for load balancing and pair the charger with the Ohme app. You choose between a tethered lead and a socket before we order the unit.

### Do I need an earth rod for an Ohme charger?

Usually not. Ohme chargers detect a PEN fault themselves and stop the charge, so the existing earth often serves. We test the earthing first and tell you if your supply needs more.

### Why does my Ohme charger show offline?

The charger has lost its internet link. A weak wifi signal at the wall or a changed router password are common causes. We check the signal at the unit and test the circuit, then reconnect the charger in the app.

### Can you move my Ohme charger to another wall or a new house?

Yes. We disconnect the unit, make the old circuit safe and refit the charger on a new circuit where you want it. At a new property the CT clamp goes on the meter tails there, and we pair the charger with the app again.

### Will my fuse board take an Ohme charger?

It needs a spare way, plus a main fuse that can carry the charger along with the rest of the house. The CT clamp lets the Ohme slow down when the house is busy, which often avoids a supply upgrade. If the board is full, we quote a board change as a separate job.

## Business facts
- Service area: Peterborough, Colchester, Witham, Maldon, Wivenhoe, Tiptree, Kelvedon, West Mersea, Stanway, Brightlingsea, Coggeshall, Marks Tey, Dedham, Rowhedge, Great Horkesley, Heybridge, Silver End, Stamford, Whittlesey, Oundle, Huntingdon, Manningtree
- Calls: Calls answered 24/7
- Phone: +447414545781
- Email: team@lightingelectrical.co.uk
- Insurance: Public liability £2M, Employers' liability £10M, Professional indemnity £500K

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)