title: "Burning smell from a socket | 4.7 Star · NAPIT approved · From £60"
description: "Burning smell from a socket in Peterborough: the connection is overheating. Lighting Electrical isolates the circuit and names the failed part."
canonical: "https://lightingelectrical.co.uk/problems/burning-smell-from-socket"
---

# Burning smell from a socket

> Burning smell from a socket in Peterborough: the connection is overheating. Lighting Electrical isolates the circuit and names the failed part.

A burning smell from a plug socket means the connection is overheating and that circuit should be switched off. Lighting Electrical in Peterborough isolates the circuit and names the failed part.

## Why does a socket smell of burning?

The smell is hot plastic from a connection that is overheating. One socket can scorch on its own. Other circuits can stay on. The heat is in the joint, the plug or the cable that is carrying too much current.
- **A loose terminal sparking in the socket:** A terminal is the metal clamp that holds the cable in the socket. When the clamp loosens, current sparks across the gap. That spark is called arcing. It cooks the plastic until you smell it at the pin holes.
- **Too many appliances on one socket:** A socket is built for a limited current. A heater, a tumble dryer or a loaded extension lead pushes the contacts harder than they can pass cleanly. The face warms first. The burning smell follows.
- **A melted plug in a sound socket:** Bent or blackened pins make a poor contact in the holes. Heat builds in the plug body. The smell seems to come from the wall. Pulling that plug out and leaving the socket empty stops the heat at the face.
- **A ring circuit loaded on one leg:** Many socket circuits are a ring, a loop of cable that leaves the fuse board and comes back to it. If one leg of the loop is broken, the other leg carries every appliance. A socket on the loaded leg then runs hot and smells.

## What can I check safely on a burning socket?

You can make the socket safe without opening it. Use the breaker handle, pull the plugs and look at the face. Keep the fuse board cover on and keep tools away from the terminals.
- **Switch the socket circuit off at the breaker:** The breaker is the switch on the fuse board for that circuit. Push the handle down while the cover stays shut. One try is enough. If the board itself is hot or smelling, step back. Leave every handle as it is.
- **Pull the plugs and look at them:** Take every plug out of the socket that smells, including extension leads. Look for brown pins, a soft plug body or a cracked casing. A damaged plug can be the whole fault. Leave those plugs out.
- **Brown marks or warmth on the socket face:** Look around the pin holes for brown stains or a shiny scorched patch. Feel the face with the back of your hand only after the breaker is off. Do not undo the face screws.
- **Whether one socket or several are affected:** Plug a lamp you already trust into a socket in another room. If only one socket smells and the others work, the fault is at that face or its plug. If several sockets are dead or hot, the fault is further along the circuit.

## When should I book for a burning socket smell?

Book Now if the socket smells of burning, feels warm, shows brown marks, or the breaker will not stay on. Leave that circuit off until we test it.
- **The socket smells, smokes or shows brown marks:** Hot plastic, a wisp of smoke or brown stains at the pin holes mean a joint is burning. Switch the circuit off at the breaker handle. Book Now. Do not plug anything back in.
- **The breaker drops out again:** You have removed the plugs and the breaker still opens. The fault is in the socket or the cable, not in a portable appliance. Another reset heats the joint. Leave the handle down.
- **The smell returns with one appliance:** The breaker held until you plugged one item back in, then the smell or the trip returned. That appliance stays unplugged. The socket still needs a test. Heat at the pins can mark the contacts.

## What happens on a burning socket visit?

We switch off the hot circuit first, then test it and name the failed part before anything is replaced. Other circuits stay on where the fuse board allows that.
- **The hot socket comes off first:** We ask which socket smells and when it started. We switch that circuit off at the breaker. We prove it is dead with a tester. No screw comes out until that test is done. Healthy circuits stay on.
- **Tests on the dead socket circuit:** With the circuit off we measure whether the cable is complete, shorted or leaking to earth. Earth is the safety path that carries fault current away from you. The readings separate a burnt socket, a broken ring leg and a failed breaker.
- **The failed part is named before it is changed:** We open only the socket that failed the test. A sound socket stays shut. We tell you whether the face, the terminal, the cable or the breaker has burnt. The repair starts once you accept it.
- **The circuit is tested again after the repair:** We test the circuit after the work. Where the circuit was altered we issue a minor works certificate under our NAPIT registration. If it is not safe to switch on, the breaker stays off. Before a further price we check bonding, the link from metal pipes to the fuse board. We also check whether the supply can carry the load.

## What does a burning socket visit cost?

The emergency electrician price covers attendance, switching off the hot socket circuit, the first tests, and making that circuit safe to leave. Time spent tracing the cable past that socket, a replacement part, or a minor works certificate changes the price. Fuse board replacement is written separately when the tests show the board has failed.
- Emergency electrician (out of hours): from £90 an hour
- We fit a socket from Hager, Wylex, Contactum, BG Electrical or MK Electric only when that socket has failed the test.
- Tracing a burning joint along the cable takes longer than changing the one socket that has scorched.
- An Electrical Installation Condition Report, called an EICR, is priced on its own when the whole installation needs inspecting.

## Questions about a burning smell from a socket

### Is a burning smell from a socket an emergency?

Yes. A hot joint scorches the cable behind the socket face while the circuit stays on. Switch that breaker off and Book Now. We test the circuit before the socket is used again.

### Can I still use the other sockets in the house?

Other sockets stay on when they have their own breaker. We switch off only the circuit that feeds the burning socket. If the fuse board smells as well, more of the board stays off until we test it.

### Will you replace the socket on the same visit?

We replace it on the visit when the test shows that socket has failed and you accept the repair. We do not change a socket that tests sound. A fuse board change, when the board itself has failed, is priced as its own job.

### What paperwork do I get after the repair?

A minor works certificate comes with a repair that changes the socket or the cable. It records the test results for that work and our NAPIT registration. A full inspection of the installation is a separate EICR booking.

### What if the plug smells and the socket looks fine?

Unplug it and leave it out. A melted plug can heat a sound socket, and a hot socket can ruin a sound plug. We test the socket with the appliance disconnected and tell you which of the two has failed.

## Related problems
- [Brown marks on a socket or plug](https://lightingelectrical.co.uk/problems/scorch-marks-on-socket): Brown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- [Burning plastic smell from electrics](https://lightingelectrical.co.uk/problems/burning-plastic-smell-electrical): A burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- [Burning smell from the fuse box](https://lightingelectrical.co.uk/problems/burning-smell-from-fuse-box): A burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- [Electric shock from a light switch](https://lightingelectrical.co.uk/problems/electric-shock-from-light-switch): A shock from a light switch means the switch face is carrying current and that lighting circuit should be isolated.
- [Electric shock from the shower](https://lightingelectrical.co.uk/problems/electric-shock-from-shower): A shock from the shower means current is on the water, the case or the taps, so that circuit stays off until it is tested.
- [Electrical arcing or crackling sound](https://lightingelectrical.co.uk/problems/electrical-arcing-sound): A crackling noise is a spark at a loose or burnt joint, so that circuit stays off until it is tested.

## Sources
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [HSE: Electrical Safety at Work](https://www.hse.gov.uk/electricity/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)

Updated 2026-11-16.

[Emergency electrician](https://lightingelectrical.co.uk/services/emergency-electrician)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)