# Trip switch won't go back up

> A trip switch that will not stay up in Peterborough is tested by Lighting Electrical. We isolate the failed circuit and leave sound circuits on.

When a trip switch will not stay up, Lighting Electrical in Peterborough isolates that circuit, tests it, and leaves the other circuits on where the board allows.

## Why will a circuit breaker not reset?

A breaker will not reset because a fault is still on its circuit, or because the breaker itself will not latch. Lifting the handle again leaves that fault in place.
- **A short is still on the circuit:** A short joins live to neutral, or live to earth. Earth is the safety path that carries fault current away from you. The breaker opens to stop that current. It will not latch while the short remains.
- **Current is still leaking to earth:** An RCD is a switch that opens when current leaks to earth. It will not hold while the leak continues. An RCBO guards one circuit as both a breaker and an RCD, so only that circuit stays off.
- **The circuit is still overloaded:** Heaters, a kettle or a charger left on can draw more current than the breaker is marked for. The handle drops again as soon as it is lifted. The extra load has to come off before the breaker can stay up.
- **The breaker mechanism has failed:** The latch inside the breaker can fail on its own. This shows up on Hager, Wylex, Contactum, BG Electrical and MK Electric devices. The cable can test clear and the handle still refuses to stay up.
- **Water has reached a fitting:** Rain in an outside light, or a splash on a socket, gives current a path to earth. The protective device opens. It stays open until that fitting is dry and the leak has gone.

## What can I check with the fuse board cover on?

You can read the switches through the closed cover, unplug portable appliances, and try one reset if the board is cool, quiet and free of any burning smell. Covers and fittings stay shut.
- **Which switch is sitting down:** Look through the closed cover. A single breaker down means one circuit has opened. An RCD down can take several circuits with it. Write down the label beside the switch that has opened.
- **One reset after plugs are out:** Pull the plugs on portable appliances on that circuit. Lift the handle once, and only if the board is cool and quiet. If the handle drops at once, leave it down.
- **Which rooms and appliances went off:** Note whether the lights, the sockets or one appliance died. A lamp you already trust shows whether a socket still has power. That note shows which circuit we test first.
- **Heat, a smell or a wet fitting:** Brown marks, a buzz, a burning smell or a wet outside light mean you stop. Leave the switch down. Keep your hands off screws, cables and the wet plastic.

## When should I book if the trip switch will not stay up?

Book Now when the switch drops again after one try, or when the board is hot, noisy or smells of burning. That circuit stays switched off.
- **The handle drops straight away:** The fault is still on the circuit or in the breaker. Another reset heats the terminals. Leave the handle down so the cable stays cool.
- **The board is hot or smells of burning:** Heat, a buzz or a burning smell means a joint is failing inside the board. Use only the handle on the front. Leave the cover screws where they are.
- **Several circuits have gone off together:** An RCD that will not hold has opened more than one circuit. Much of the house can be dark. The leaking circuit needs a test before those switches go back up.
- **Water is on a light or a socket:** A soaked outside light or a flooded socket can hold the protective device open. Leave that switch down. Keep your hands away from the wet fitting.

## What happens on a visit for a breaker that will not reset?

We find the device that will not hold, test that circuit while it is dead, and name the failed part before anything is changed. Sound circuits stay on when the board allows it.
- **The switch that has opened:** We ask which rooms went dark and when the handle last stayed up. We read the fuse board with you. We switch off the failed circuit. Healthy circuits remain supplied when their own devices allow it.
- **Tests with the circuit dead:** A dead test measures the cable while it is switched off. The readings show a short, a break or current leaking to earth. They separate a breaker, a socket, a joint and a length of cable.
- **Earthing and supply before a price:** We name the failed part before any fitting comes off. Earthing is checked, because that path lets a breaker open on a fault. Bonding, the link from metal pipes to earth, is checked too. We also check the supply can carry the load before any further price is written.
- **The repair or a safe switch off:** The repair goes ahead once you say yes to it. We test the circuit again afterwards. A minor works certificate records a change to the circuit, with our NAPIT registration. Fuse board replacement is a later job when the board itself has failed. An unsafe circuit is left switched off.

## What does it cost when a breaker will not reset?

The time taken to trace a breaker that will not hold sets the price. That price covers the tests, the diagnosis and the repair after you say yes to it. A new breaker, a minor works certificate or a separate fuse board replacement changes the price. Emergency electrician attendance is charged on its own.
- Emergency electrician (out of hours): from £90 an hour
- A Hager, Wylex, Contactum, BG Electrical or MK Electric breaker is fitted only when tests show it has failed.
- Fuse board replacement carries its own written price when tests show the board has failed.
- Emergency electrician is a separate charge from Electrical Fault Finding & Repair.

## Questions about a trip switch that will not stay up

### Should I reset a trip switch more than once?

One lift is enough, after portable plugs are out, and only while the fuse board is cool and quiet. A second drop means the fault is still there. Leave the handle down so the terminals do not heat up.

### Will a new fuse board stop the tripping?

A new fuse board helps only when the tests show the board has failed. A short in a cable, or a wet outside light, still opens a breaker on a new board. Fuse board replacement is priced on its own after those tests.

### What paperwork do I get after the repair?

Where the circuit is altered, a minor works certificate lists the tests for that work and our NAPIT registration. If we only isolate the circuit, you still get the readings and the name of the failed part. An EICR is a separate inspection of the whole installation.

### Can the rest of the house stay on?

A breaker for one circuit can stay down while the other circuits remain on. An RCD that covers several circuits holds those circuits off until the leak is found. We switch back only the circuits that test sound.

### Do you repair the breaker on the same visit?

We name the failed breaker, cable, joint or fitting before a part is fitted. That repair can go ahead on the visit once you say yes to it. Any part that has to be ordered is priced in writing before it is fitted.

## Related problems
- [Brown marks on a socket or plug](https://lightingelectrical.co.uk/problems/scorch-marks-on-socket): Brown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- [Burning plastic smell from electrics](https://lightingelectrical.co.uk/problems/burning-plastic-smell-electrical): A burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- [Burning smell from a socket](https://lightingelectrical.co.uk/problems/burning-smell-from-socket): A burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- [Burning smell from the fuse box](https://lightingelectrical.co.uk/problems/burning-smell-from-fuse-box): A burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- [Electric shock from a light switch](https://lightingelectrical.co.uk/problems/electric-shock-from-light-switch): A shock from a light switch means the switch face is carrying current and that lighting circuit should be isolated.
- [Electric shock from the shower](https://lightingelectrical.co.uk/problems/electric-shock-from-shower): A shock from the shower means current is on the water, the case or the taps, so that circuit stays off until it is tested.

## Sources
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [HSE: Electrical Safety at Work](https://www.hse.gov.uk/electricity/)

Updated 2026-11-16.

[Emergency electrician](https://lightingelectrical.co.uk/services/emergency-electrician)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)