# Consumer unit tripping with nothing plugged in

> Consumer unit tripping with nothing plugged in. Lighting Electrical in Peterborough tests fixed circuits and names the safety switch or cable at fault.

A consumer unit that trips with nothing plugged in has a fault in the fixed wiring or in the safety switch. Lighting Electrical in Peterborough tests the circuits and names the part that opens it.

## Why does a consumer unit trip with nothing plugged in?

Fixed wiring or the safety device is at fault, because the sockets are already empty. Current leaking to earth, or a device that will not hold, opens the switch.
- **Leakage to earth on fixed wiring:** An RCD is the safety switch that opens when current leaks to earth. Earth is the safety path back to the consumer unit. A nail through a cable, a wet outside light or a failed immersion element leaks while every socket is empty.
- **Neutral touching earth:** Neutral is the conductor that carries current back. When neutral touches earth in a joint or a cable, current leaves the circuit. The RCD opens with every socket empty.
- **A worn RCD or RCBO:** An RCBO guards one circuit as both a breaker and an RCD. A worn RCD or RCBO opens while the cables are sound. The device will not hold, so the circuits stay off until it is replaced.
- **Water in a connected fitting:** Rain in an outside light, steam in a bathroom fan or a leak in the loft wets a fitting that stays connected. Water joins a live part to earth. The RCD opens.
- **Fixed equipment still connected:** The immersion heater, the electric shower and the hard wired oven stay connected after you empty the sockets. A failing heating element leaks to earth. The RCD for that circuit opens.
- **Several circuits on one RCD:** A split load consumer unit places several circuits under one RCD. Small leaks from the lights, the immersion and the shower add together. The RCD opens after the plugs are out.

## What can I check safely with nothing plugged in?

You identify the open switch, the circuit and any fixed appliance with the cover shut. You use the switch handles and the wall switches only.
- **Which switch has opened:** The main switch controls the whole consumer unit. An RCD shows a test button and sits over several circuit breakers. An RCBO sits on one circuit. You write down the name next to the switch that has opened. The cover stays shut.
- **Circuit breakers one at a time:** You switch every circuit breaker off at its handle. You put the RCD back on once, with the cover cool, quiet and dry. You switch one breaker on. If the RCD opens, you switch that breaker off and leave it off.
- **Wall switches for fixed equipment:** You turn off the immersion switch, the shower switch and the oven switch on the wall. You reset the RCD once. If it holds, you leave that wall switch off. You leave the appliance cover on.
- **Heat, noise, smell or water:** A warm cover, a buzz, a burning smell or water staining means you stop. You leave the opened switch off. Book Now.

## When should I book for a tripping consumer unit?

Book Now when the safety switch opens again after one reset, or when the consumer unit is hot, noisy, wet or smelling of burning.
- **It opens again after one reset:** The plugs are out and the RCD or RCBO opens straight away. The fault sits in the fixed wiring or in the device. Further resets heat the terminals, so you leave the switch off.
- **Lights and sockets drop together:** One RCD feeds several circuits, so a leak on one circuit cuts the others too. Empty sockets do not stop that. Book Now and leave the RCD off.
- **The board is hot, wet or smelling:** Heat, a buzz or a burning smell at the consumer unit means a joint inside is failing. Water stains on an outside light mean a leak to earth. You keep the cover on and Book Now.
- **It holds, then opens later:** The consumer unit stays on for a time and then opens with the sockets still empty. Heat or rain is driving a leak on the fixed wiring. Book Now so that circuit can be tested.

## What happens on a visit for a tripping consumer unit?

We isolate the circuit that trips, test it while it is off, and name the failed part before any repair. The repair starts once you accept it.
- **What opened, and how fast:** We ask whether the main switch, an RCD or one RCBO opened, and whether it opened at once or after a wait. We read the consumer unit with you while the cover is on. We note each wall switch you have already turned off.
- **Dead tests on each circuit:** We switch off the circuit that trips. An insulation test checks the cable for leaks while the cable is dead. We move across the circuits under that RCD until one reading shows the leak.
- **The part that failed:** We tell you whether a cable, a fitting, a fixed appliance or the device has failed. We change a Hager, Wylex, Contactum or BG Electrical device only when that device has failed the test. Bonding is the link between metal pipes and the consumer unit. We test bonding, the earth path and whether the supply can carry another load before we price any further work.
- **The repair and the certificate:** Once you accept the repair we fit the failed part and dress the cables back into the consumer unit. We test that circuit again. Where the circuit changes, we write a minor works certificate under our NAPIT registration. Where the consumer unit has failed, we price fuse board replacement on its own and leave the faulty switch off.

## What does a tripping consumer unit visit cost?

Electrical Fault Finding & Repair is charged by the hour. The price covers the tests, the diagnosis we give you on the day, and the start of the repair once you accept it. Tracing a leak across several circuits takes longer than replacing one failed RCD. A part, a minor works certificate, fuse board replacement or emergency electrician attendance changes the price.
- Fault finding & repair: from £75 an hour
- Testing every circuit under one RCD takes longer than testing a single RCBO that will not hold.
- We add a breaker, an RCD, a fitting or a length of cable only when the test shows it has failed.
- Fuse board replacement and emergency electrician attendance are priced as separate jobs.

## Questions about a consumer unit tripping with nothing plugged in

### Will you change the consumer unit before you find the fault?

No. We name the failed cable, fitting, fixed appliance or safety device before any part is changed. The repair of that part starts once you accept it. Fuse board replacement is a separate job when the consumer unit itself has failed.

### Why does it still trip after I unplug everything?

Unplugging clears portable appliances only. The immersion, the shower, the oven, the lights and outside fittings stay connected. A leak on one of those, or a worn RCD, opens the switch.

### Is it safe to reset the switch?

A single reset is fine when the cover is cool, dry and quiet. If the switch opens again, leave it off and Book Now. Resetting it over and over heats the terminals.

### What paperwork do I get after the repair?

A minor works certificate records a repair that changes a circuit, including the test results and our NAPIT registration. An EICR is a full inspection of the installation and stands as its own job. Where we change nothing, we still tell you the failed part and the readings.

### Will the rest of my house stay on during the repair?

Yes. We switch off only the circuit that is leaking. The other circuits stay on. The failed circuit goes back on after the repair, and it stays off if it is unsafe to switch on.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.
- [Electric boiler trips the electrics](https://lightingelectrical.co.uk/problems/electric-boiler-tripping-electrics): An electric boiler trips the electrics when its circuit leaks to earth or draws more current than its breaker allows.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [IET: BS 7671 Guidance Publications](https://electrical.theiet.org/guidance-and-codes-of-practice/publications-by-category/bs-7671-and-guidance/)

Updated 2026-11-16.