# Driveway lights not working

> Driveway lights not working in Peterborough start with the outdoor circuit. Lighting Electrical tests the fuse board, the sensor and the lantern.

A dark driveway with the house lights still on means the outdoor lighting has failed on its own. Lighting Electrical traces that run from the fuse board in Peterborough.

## Why do driveway lights stop working?

Driveway lights stop because the outdoor circuit has opened or a lantern, sensor or joint on it has failed. A separate breaker leaves the rooms lit. A shared lighting breaker takes those indoor lights with it.
- **The outdoor breaker has opened:** A breaker is the switch in the fuse board that guards one circuit. Driveway lanterns sit on their own breaker or on a shared lighting breaker. A short, where live touches neutral, opens that switch and the lanterns go dark.
- **Current leaking to earth outdoors:** An RCD is a safety switch that turns off when current leaks to earth. Earth is the path that carries a fault away from you. Rain in a lantern or a wet joint sends current down that path, the RCD opens, and the driveway goes dark.
- **A sensor that no longer switches:** A PIR is a passive infrared sensor that turns a lantern on when it sees movement. A photocell turns a lantern on at dusk. When either sensor fails, the lamp stays off even though the cable still has power.
- **A broken cable under the drive:** Armoured cable is a cable with a steel wrap for a buried run. Digging, a crushed duct or a loose gland opens that cable. A gland is the seal where the cable enters a box. Lanterns past the break go dark and lanterns before it stay lit.
- **A failed lamp inside the lantern:** Many driveway lanterns use a sealed lamp and a driver. The driver is the part that feeds the lamp. When the lamp or the driver fails, that one lantern stays dark and the rest of the run stays lit.

## What can you check safely on driveway lights?

You can read the indoor switch and the fuse board with the cover shut. You can look at the lanterns from the ground. You leave every screw in place.
- **The switch that feeds the driveway:** Turn the indoor driveway switch on. Darkness after that means the fault sits past the switch.
- **The fuse board with the cover shut:** Read the breaker names through the closed cover. A breaker sitting down is the circuit that opened. Reset that breaker once while the board stays cool and silent, with no burning smell. When that breaker falls again at once, leave the handle down.
- **Which lanterns are dark:** Look along the drive and at the porch. Every outside lantern dark points to the breaker or the RCD. One lantern dark points to that lamp, that sensor or the joint beside it.
- **Water you can see from outside:** Look at the globe and the box under the lantern without opening them. Water sitting inside the globe, or green crust on the metal, shows the seal has let rain in. Keep your hands off the wet fitting.

## When should you book for driveway lights?

Book Now when a reset fails to hold. Rain that knocks the lights out needs the same visit. A hot lantern or a burning smell needs it too.
- **The breaker will not stay up:** The driveway switch on the fuse board opens again after one reset. The fault is still on the cable, a lantern or the protective device. A second reset warms the terminals, so leave that breaker off.
- **The lights die after rain:** Rain that fills a lantern or a joint leaks current to earth. The RCD or the breaker opens and the drive goes dark. Leave that circuit switched off.
- **A lantern that is hot or buzzing:** A warm lantern, a buzz or a burning smell means a joint is arcing. Arcing is a spark jumping a loose connection. Turn the outdoor breaker off by its handle. Leave every lantern screw where it is.
- **Only some of the lanterns work:** Lit lanterns beside dark ones mean the cable is open at a joint part way along the drive. The lit fittings stay in use. The dark run needs a test before that joint overheats.

## What happens on a driveway light visit?

We begin on the outdoor circuit at the fuse board. We say which lantern, sensor, joint or cable has failed before we change it. Any repair waits until you say yes.
- **Which lanterns failed and when:** We ask which lanterns are dark, whether they failed at dusk, after rain or all day, and whether a sensor used to switch them. We read the outdoor breaker with you while the fuse board cover stays shut.
- **Tests on the dead outdoor circuit:** We switch that circuit off at its breaker. With the breaker off we measure the outdoor cable. The readings separate a broken conductor, a short and a leak to earth.
- **The failed lantern, sensor or cable:** We open only the fitting or the enclosure the readings point to. A sound lantern stays shut. We name the failed sensor, lamp, gland or length of armoured cable before any part is changed.
- **The repair and the certificate:** We fit the failed part when you say yes to the repair. We test the circuit again. A minor works certificate records that change and carries our NAPIT registration. We put the breaker back on when the circuit is safe to leave live, and we leave it off when it is not.

## What does a driveway lighting fault cost?

Electrical Fault Finding & Repair is charged by the hour. That price covers the tests on the driveway lights, the spoken diagnosis, and the repair when you say yes to that work. A sensor on a wall takes less time than armoured cable under the drive. A new lantern, a minor works certificate or a fuse board replacement changes the price. Emergency electrician work is charged on its own.
- Fault finding & repair: from £75 an hour
- Where the outdoor breaker has failed we fit a Hager, Wylex, Contactum, BG Electrical or MK Electric device.
- The minor works certificate is added only when the repair changes the circuit.
- Fuse board replacement is written up on its own when the outdoor breaker or the board has failed.

## Questions about driveway lights not working

### Will the rest of the house stay on?

Yes, we switch off only the outdoor circuit that feeds the driveway lanterns. Every other circuit stays on. We put the outdoor breaker back on after the work when the circuit is safe to leave live, and we leave it off when it is not.

### Do you change the lantern before you know the fault?

No. We test first and name the failed sensor, lamp, joint or cable. The repair of that part starts when you say yes. A lantern that tests sound stays on the wall.

### What if only the sensor has failed?

A failed PIR or photocell leaves the lamp dark while the cable is still sound. We replace that sensor when you say yes to the repair. The rest of the driveway run stays as it is.

### Do I get paperwork after the repair?

Where the repair alters the outdoor circuit, we issue a minor works certificate. The certificate lists the tests for that job and our NAPIT registration. An EICR, the Electrical Installation Condition Report, is a different inspection and a different job.

### Will a new fuse board bring the driveway lights back?

A new fuse board brings the lanterns back only when the tests show that board has failed. A gland full of water or a cut armoured cable stays dark on a new board. We price a board change as its own job after the outdoor tests.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Electric boiler trips the electrics](https://lightingelectrical.co.uk/problems/electric-boiler-tripping-electrics): An electric boiler trips the electrics when its circuit leaks to earth or draws more current than its breaker allows.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [IET, Guidance Note 7: Special Locations](https://electrical.theiet.org/guidance-and-codes-of-practice/publications-by-category/bs-7671-and-guidance/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)

Updated 2026-11-16.