---
title: "EICR C2 Meaning: Potentially Dangerous, Fix It Urgently"
description: "EICR C2 meaning in Peterborough: what the code flags, what to check safely, when to book and what Lighting Electrical does on the visit. · Prices from £60"
canonical: "https://lightingelectrical.co.uk/problems/eicr-c2-meaning"
---

# EICR C2 Meaning: Potentially Dangerous, Fix It Urgently

> EICR C2 meaning in Peterborough: what the code flags, what to check safely, when to book and what Lighting Electrical does on the visit. · Prices from £60

Lighting Electrical in Peterborough clears EICR C2 codes. A C2 marks a fault that becomes dangerous if something else goes wrong, and the report stays unsatisfactory until each one is put right.

## Why does an inspector code something C2?

A C2 goes against a fault that is harmless today but turns dangerous after a second failure. Most come from missing or weak protection rather than damage you can see.
- **Sockets with no RCD protection:** A residual current device (RCD) is a switch that cuts the power within a fraction of a second when current leaks. A socket that could feed outdoor equipment, or one in a bath or shower room, needs it. Without it, a leak runs through whoever touches the fault.
- **An RCD that fails its test:** The tester applies a small controlled leak and times the response. An RCD that is slow, or does not trip at all, fails that check, so the protection you assume is there does nothing.
- **Earthing or bonding that is missing or too thin:** Earthing gives fault current a safe path back to the supply, and bonding links metal pipework to that path. A conductor that is absent, too thin or disconnected leaves taps and pipes able to carry live voltage.
- **Heat damage to fittings or the consumer unit:** Scorched sockets, browned insulation, cracked faceplates and heat marks on the consumer unit (the fuse box) all show energy escaping as heat. Heat damage leads to fire, so the inspector codes it C2.
- **A breaker that clears a fault too slowly:** Every circuit relies on a fuse or breaker to switch off fast in a fault. When the measured loop impedance, the resistance of the fault path, is too high, the device takes too long and the cable heats up first.

## What can I look at myself after a C2?

None of these checks open anything. They cover reading the report, looking and listening from a safe distance, and pressing one button on the front of the board.
- **Mark every C2 and FI line in the report:** Each observation carries an item number and a code. Note the lines coded C2, and any coded FI, which means the inspector could not tell and needs to investigate further. Ask the person who wrote the report to explain each one.
- **Look, listen and smell without touching inside:** Check sockets, switches and the consumer unit for brown marks, a burning smell or a buzzing sound. Rest the back of your hand on a faceplate to feel for warmth. If you find any of these, switch that circuit off at its breaker and stop using it.
- **Press the RCD test button:** The button sits on the front of the consumer unit, marked T or Test, and needs no cover removed. The power cuts out, so save your work first, then switch it back on. If nothing trips, tell us straight away.
- **Unplug what runs from a flagged circuit:** If a C2 names a particular circuit, take heaters, chargers and power tools off it until the work is done. Leave the repair itself to an electrician.

## How soon should I book after a C2?

Book once the report is in your hands. A C2 asks for action soon, and it does not wait for a convenient moment.
- **Today if anything heats, smells or trips:** Switch that circuit off at its breaker and call us. A circuit doing any of these has gone past a C2 on paper, and it gets looked at before anything else.
- **Within 28 days as a landlord in England:** The rules for rented homes set 28 days from the report, or less if the report names a shorter time. Send us the report as soon as it arrives so the quote and the work fit inside that window.
- **Soon as an owner occupier:** No legal deadline applies to your own home. Until the work is done, though, a protection you expect to be there is missing or weak, so book it in the coming days.

## What happens when you come to fix a C2?

We start from the report in your hand and finish with paperwork that shows each item is cleared.
- **Walking through every C2 and FI item:** We show you where each flagged item sits in the property and explain in plain words why it was coded that way.
- **Checking the installation before we price:** We check the earthing, the bonding and whether the supply carries any extra load before we price the work. You then receive the price in writing before anything is touched.
- **Repairing and retesting the circuits:** We carry out the repair, then test every circuit we touched so the RCD and breakers are shown to switch off in time.
- **Certificate and written confirmation:** You get an electrical installation certificate for a larger job or a minor works certificate for a small one, plus written confirmation that the C2 items are cleared.

## What does the C2 repair price cover?

The price covers the repair of each coded item, testing of every circuit we alter and the certificate for that work. It is written down before we start. What changes it is what the report found, not the letter C2 on its own.
- EICR (electrical safety report): from £150
- Adding RCD protection to one circuit is less work than replacing a consumer unit, so the type of fix moves the price most.
- Earthing and bonding corrections depend on where the metal pipework enters the property and how far the new conductors must run.
- An FI item needs investigating first, and what that uncovers adds work to the quote or takes it away.

## EICR near you
- [EICR in Silver End](https://lightingelectrical.co.uk/electrician-silver-end/eicr)
- [EICR in Marks Tey](https://lightingelectrical.co.uk/electrician-marks-tey/eicr)
- [EICR in Kelvedon](https://lightingelectrical.co.uk/electrician-kelvedon/eicr)
- [EICR in Witham](https://lightingelectrical.co.uk/electrician-witham/eicr)
- [EICR in Great Horkesley](https://lightingelectrical.co.uk/electrician-great-horkesley/eicr)

## C2 questions answered

### Is it safe to keep using my electrics with a C2?

Yes in the meantime, but a fault would carry a shock or fire risk without the protection you expect. Stop using any circuit that feels warm, smells or trips, and call us straight away.

### Will my EICR pass if it has a C2?

No. A single C1 or C2 makes the whole report unsatisfactory, however tidy the rest looks. A C3 is a recommendation and does not fail it.

### How long does a landlord have to fix a C2?

A landlord in England must complete the remedial work within 28 days of the report, or sooner if the report says so. Send us the report as soon as you have it so the work fits inside that time.

### What paperwork do I get once the C2 is fixed?

You get a minor works certificate for a small repair or an installation certificate for a larger one, plus written confirmation that the C2 items are cleared. Keep both with the property's electrical records and pass copies on when a tenant or the council asks.

## Related problems
- [Aluminium wiring in the house](https://lightingelectrical.co.uk/problems/aluminium-wiring): Aluminium cable overheats at loose joints. We test it, write the electrical installation condition report, and price any copper replacement separately.
- [Are sockets in skirting boards illegal?](https://lightingelectrical.co.uk/problems/sockets-in-skirting-boards): No, low sockets are not illegal. The age and condition of the wiring behind them is what an EICR tests.
- [Buying a house with old electrics](https://lightingelectrical.co.uk/problems/buying-house-old-electrics): An EICR sets out the condition of old electrics before you buy, circuit by circuit.
- [House not up to electrical regulations](https://lightingelectrical.co.uk/problems/house-not-up-to-electrical-regs): An EICR names the parts of the fixed wiring that fall short of the current rules, and repairs are priced afterwards.
- [How to tell if a house needs rewiring](https://lightingelectrical.co.uk/problems/signs-house-needs-rewiring): The house needs rewiring when an EICR shows the cables or the fuse board cannot be made safe by repairing one circuit.
- [Is my metal fuse box safe?](https://lightingelectrical.co.uk/problems/metal-fuse-box): A metal cover does not make a fuse box safe. The devices, earthing and cables settle that, and an EICR records the result.

## Sources
- [Electrical Safety First: Best Practice Guide 4, EICR classification codes](https://www.electricalsafetyfirst.org.uk/media/2depcuen/best-practice-guide-4-issue-6.pdf)
- [IET Wiring Matters: EICR myths](https://electrical.theiet.org/wiring-matters/years/2021/85-may-2021/eicr-myths/)
- [GOV.UK: Electrical safety standards in the private and social rented sectors](https://www.gov.uk/government/publications/electrical-safety-standards-in-the-private-and-social-rented-sectors-guidance/electrical-safety-standards-in-the-private-and-social-rented-sectors-guidance)

Updated 2026-11-27.

[EICR](https://lightingelectrical.co.uk/services/eicr)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)
