# Electric heater not working

> Electric heater not working in Peterborough: Lighting Electrical tests the heater circuit, names the failed part, and repairs it once you accept the work.

An electric heater that stays cold has lost its supply or the heater has failed. Lighting Electrical tests that supply in Peterborough and names the failed part.

## Why is my electric heater not working?

An electric heater stays cold when its supply has opened, the wall isolator is off, or a part inside the heater has failed. Heaters on a separate circuit can still run.
- **The heater breaker has opened:** A breaker is the switch in the fuse board that protects one circuit. A fixed heater often has a breaker to itself. The breaker opens on a short or on too much current, and that heater goes cold while the lights stay on.
- **The heating element has failed:** The element is the part that makes the heat. It can break and leave the heater cold while the breaker stays up. It can also leak current as it warms, which opens the RCD, the device that cuts power when current leaves the circuit. A failed thermostat, the control that switches the element with the room temperature, leaves the element off as well.
- **The isolator is off or burnt:** An isolator is the switch beside a fixed heater that cuts power to it. We fit that switch with an infrared heater, including one above a shop front doorway. With the isolator off, or with its contacts burnt, the heater stays cold even though the breaker is up.
- **The fused connection has overheated:** A fused connection unit feeds one fixed heater through a fuse in its face. Loose terminals heat up and the connection fails. The heater goes cold, and brown marks can appear around that unit.
- **The plug or flex has failed:** A portable heater pulls a heavy current through its plug and flex. A broken conductor or a blown fuse in the plug stops the heat. A lamp can still light in the same socket, which shows that socket is live.
- **Too many heaters on one breaker:** Each heater draws a high current. Two or more on one breaker can pull more than that breaker allows. The breaker opens and those heaters go cold together.

## What can I check safely on a cold heater?

You can check the heater controls, the closed fuse board and a second socket without opening the heater or touching the wiring.
- **The controls and the isolator:** You set the thermostat higher than the room and switch the heater on. On a fixed heater you turn the wall isolator on. If a timer controls the heater, you set it to constant heat. The heater case stays shut.
- **The breaker with the cover shut:** You look at the fuse board and leave the cover on. A lever sitting down is the circuit that opened. You raise that lever once, and only when the board is cool and has no burning smell. A lever that falls straight back stays down.
- **A second socket for a portable heater:** You unplug the heater and try it in a socket where a lamp already lights. Heat there means the first socket was dead. No heat from a live socket means the heater or its lead has failed.
- **Which other heaters still warm:** You note which heaters still give heat. One cold heater points to its isolator, its connection or the heater. A whole group going cold together points to the breaker they share.

## When should I book for a heater that stays cold?

Book Now when the breaker will not hold, when a heater connection smells of burning, or when the safe checks still leave the heater cold.
- **The breaker will not hold:** The isolator is on and the breaker opens again. The fault is still on that heater circuit. Another reset heats the terminals, so you leave the breaker off.
- **Heat, a buzz or brown marks:** A hot isolator, a buzz, or brown marks at the heater connection mean the joint is arcing. Arcing is electricity jumping across a loose terminal and charring the plastic. You switch that circuit off at the breaker and leave the case closed.
- **One heater cold among others:** The other heaters still warm and this one stays cold with its isolator and thermostat on. The failed part is local to this heater. It needs a test at the connection and at the heater.
- **Water on the heater or isolator:** A leak onto a heater or its isolator can send current to earth. Earth is the safety path that carries a fault away from you. You leave the breaker off and keep your hands off the wet casing.

## What happens on a visit for a cold electric heater?

We start at the fuse board, test through to the heater, and name the failed part before we change anything.
- **Which heater failed and when:** We ask when the heater last gave heat and whether it is fixed or plug in. We look at the isolator and the fuse board with you. We open no cover until our tester confirms that circuit is off.
- **Tests from the board to the heater:** We isolate the heater circuit. Dead tests look for a broken conductor, a short, or current leaking to earth. The readings separate the breaker, the isolator, the fused connection and the heater.
- **The failed part named before a price for more work:** We tell you whether the fault is the heater, the flex, the isolator, the connection or the breaker. A sound heater stays in place. We check the earthing, the bonding to metalwork, and whether the supply can feed another heater, before we price any added load.
- **The repair and the certificate:** Once you accept the repair we put right the failed joint, cable, isolator or protective device, then test the circuit again. A minor works certificate records that change under our NAPIT registration. If the heater itself has failed, we leave its circuit safe and a replacement connection is a separate job.

## What does finding a cold heater cost?

The hourly charge for Electrical Fault Finding & Repair pays for measuring the cold heater circuit, explaining the failed part, and repairing that part once you accept it. A plug in heater with a tired lead takes less time than a fixed heater with a damaged cable. A replacement part, a minor works certificate, or a new heater connection changes the price.
- Fault finding & repair: from £75 an hour
- A Hager, Wylex, Contactum, BG Electrical or MK Electric breaker goes in only when tests show the heater breaker has failed.
- A replacement heater is connected under Appliance and heating connections and priced as that job.
- Fuse board replacement has its own price when tests show the board, not the heater, has failed.

## Questions about a heater that will not heat

### Will you take the heater apart before you know the fault?

No. We test at the fuse board and at the heater connection first. We open the case only when those tests show the fault is inside. A heater that tests sound stays shut.

### Can you fit a replacement heater on the same visit?

Only after the tests name the old heater as failed and you want it replaced. Connecting the new heater is Appliance and heating connections, with its own price. The fault finding hour does not include the new heater.

### Will my other heaters stay on during the visit?

Yes. We switch off the failed heater circuit and leave healthy circuits on. That circuit goes back on after a repair that tests clear. It stays off if it cannot be left live.

### Do I get paperwork after a heater repair?

You get a minor works certificate when we change the circuit, such as a connection, an isolator or a breaker. It records the tests for that job and our NAPIT registration. If the heater has failed and the wiring is unchanged, we tell you the readings and the failed part.

### What if the heater is cold only some days?

A heater that fails now and then still leaves signs at the isolator, the connection or the thermostat. If it is warm when we arrive, we still test the connection and the protective device. We then tell you the readings and what to watch if it goes cold again.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [Energy Saving Trust: Heating Your Home](https://energysavingtrust.org.uk/advice/heating-your-home/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [HSE: Electrical Safety at Work](https://www.hse.gov.uk/electricity/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)