title: "Electric radiator won't turn off | 4.7 Star · NAPIT · From £60"
description: "Electric radiator stays on in Peterborough. Lighting Electrical tests the thermostat, timer and isolator, then repairs the part still feeding the element."
canonical: "https://lightingelectrical.co.uk/problems/electric-radiator-not-turning-off"
---

# Electric radiator won't turn off

> Electric radiator stays on in Peterborough. Lighting Electrical tests the thermostat, timer and isolator, then repairs the part still feeding the element.

An electric radiator that stays on is still receiving power through a failed control. Lighting Electrical in Peterborough tests the thermostat, timer and isolator and names the part that keeps the element heating.

## Why does an electric radiator stay on?

An electric radiator stays on when power keeps reaching the element after the room is warm. The element is the part that turns electricity into heat. A failed thermostat, timer, isolator or relay holds that power on.
- **A thermostat that stays closed:** The thermostat should open once the room reaches the set warmth and cut power to the element. Contacts that have stuck shut never open, so the element keeps heating. Turning the dial down changes nothing while those contacts stay together.
- **A timer left on constant or boost:** The timer chooses the hours when the radiator is allowed to heat. Constant mode or boost keeps the supply through to the element all day. A timer with stuck contacts does the same even when the display shows off.
- **An isolator or fused spur stuck on:** The isolator is the wall switch that should cut every supply to the radiator. A fused connection unit is a switched spur that holds a fuse and should cut the supply the same way. When that switch fails on, the element stays powered.
- **A relay stuck on the element:** A relay is a small switch that the thermostat operates to feed the element. If the relay sticks closed, the element stays on after the thermostat has opened. The dial can read off while the panel remains hot.
- **The element wired to a permanent live:** A permanent live is a supply that stays on while the breaker is up. A breaker is the switch in the fuse board that guards one circuit. An element joined to that permanent live heats even when the thermostat and timer are off.

## What can I check while the covers stay on?

You can turn the thermostat down, take the timer off constant, and switch off at the wall or at the breaker handle. Every cover stays on, and you leave the radiator and the fuse board unopened.
- **The thermostat on its lowest mark:** Turn the thermostat to the lowest mark and leave the room until it is warm. A panel that stays hot means that thermostat is not cutting the element. Put the dial back only after you have seen whether the panel cools.
- **The timer taken off constant and boost:** Set the timer to off and leave constant and boost unused. If the radiator cools, the timer was keeping it on. If it stays hot, the fault sits past the timer.
- **The wall switch beside the radiator:** Switch off the isolator or the fused connection unit. A radiator that cools can still be cut by that switch. A radiator that stays hot is still receiving power, so leave the switch off and Book Now.
- **One radiator or all of them:** Note whether one radiator stays on or every electric radiator on the circuit stays on. One heater points to its thermostat, timer or wall switch. All of them point to the control or breaker that feeds the circuit.

## When should I book if the radiator stays on?

Book Now when the radiator stays hot with the thermostat down and the wall switch off, or when it smells of burning. A timer you can set back to off does not need a visit.
- **Still hot with the wall switch off:** The isolator or fused connection unit is off and the panel stays hot. Power is still reaching the element. Switch the heating breaker down by its handle and leave the cover shut.
- **Burning smell, buzz or brown marks:** A burning smell, a buzz, or brown marks on the radiator or the wall switch mean a joint is getting too hot. Use the breaker handle to switch that circuit off. Keep your hands off the screws.
- **The room is hot and the heater carries on:** The room is already warm and the radiator keeps heating. The thermostat is not opening the supply to the element. Book Now so the failed control can be tested before the fitting scorches the surround.

## What happens on a visit for a radiator that stays on?

We test the radiator circuit and name the control or switch that still feeds the element before any part is changed. The repair waits until you accept it.
- **Which radiator and which control:** We ask which radiator stays hot, and whether a thermostat or timer is in use. We ask what happened when those controls were turned down. We look at the wall switch and the fuse board while the cover is still shut.
- **Tests with the circuit switched off:** We switch the radiator circuit off at its breaker. We then test the thermostat, the timer, the isolator and the fused connection unit. The readings show which part still connects the supply to the element.
- **The failed part named before any price:** We name the failed thermostat, timer, isolator, fused connection unit or relay before anything is changed. We check earthing, bonding and whether the supply can carry the heater. Earthing gives fault current a path that opens the breaker. Bonding joins metal pipes to the fuse board.
- **Repair of the named part:** Once you accept the repair we change that named part and test the circuit again. A minor works certificate records the tests when the circuit was altered, under our NAPIT registration. When the tests show the heater itself has failed, we connect a replacement under Appliance and heating connections, priced as its own job.

## What does tracing a radiator that stays on cost?

Electrical Fault Finding & Repair is charged for the time on the radiator circuit. That price covers the tests, the diagnosis we speak through with you, and the repair of the failed control after you accept it. Replacing one isolator takes less time than tracing a thermostat along a long heater circuit. A new part, a minor works certificate, or Appliance and heating connections for a failed heater changes the price. Emergency electrician work is charged separately.
- Fault finding & repair: from £75 an hour
- The time covers the tests and the diagnosis, and the repair of the named part starts after you accept it.
- A thermostat, timer, isolator, fused connection unit or relay is fitted only after the tests show it has failed.
- A minor works certificate is added when the repair alters the circuit. Fuse board replacement carries its own written price when the heating breaker has failed.

## Questions about a radiator that will not switch off

### Can I switch the radiator off at the wall?

Yes. A sound isolator or fused connection unit cuts power to the element and the panel cools. If the radiator stays hot with that switch off, put the heating breaker down and Book Now. Leave every cover shut.

### Will you change the radiator on the first visit?

We test the thermostat, the timer, the isolator and the fused connection unit and name the part that is still feeding the element. That part is repaired on the visit after you accept the work. A replacement heater is connected only when the tests show the heater itself has failed.

### What if I can smell burning from the radiator?

Switch the circuit off at the breaker handle and stay away from the screws. A burning smell means a joint is overheating inside the radiator or the wall switch. We test that circuit and name the hot joint before any part is changed.

### Do I get a certificate after the repair?

A minor works certificate is issued when the repair alters the circuit. It records the test results and our NAPIT registration. An EICR is a separate inspection of the whole installation if you want that as well.

### Can a faulty breaker keep the radiator on?

Yes. A breaker that has stuck closed leaves the heater circuit powered. We test that breaker with the rest of the radiator circuit. Fuse board replacement is a separate written price when the test shows the board has failed.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [Energy Saving Trust: Heating Your Home](https://energysavingtrust.org.uk/advice/heating-your-home/)
- [HSE: Electrical Safety at Work](https://www.hse.gov.uk/electricity/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)