# Shock from a radiator

> Shock from a radiator in Peterborough means the metal is live. Lighting Electrical tests the bonding and the electric rail circuit, then isolates the…

A shock from a radiator means that metal is carrying a voltage. Lighting Electrical in Peterborough measures voltage on the pipe and the bonding. We then switch off the circuit feeding that metal.

## Why does a radiator give an electric shock?

A radiator shocks you because its metal has been raised above true earth. The cause is a broken supply conductor, a missing bond, or a live electric heater joined to the pipes.
- **A broken supply earth and neutral:** The cable from the network joins earth and neutral together. That combined conductor is called a PEN. If it breaks, radiators joined by bonding can rise toward mains voltage. You feel a shock when you touch the radiator and a tap or a wet floor. Phone 105 for the electricity network.
- **Heating pipes with a missing bond:** Main bonding is the green and yellow link from metal pipes to the earth bar. The earth bar is the metal strip in the fuse board where earth wires meet. A missing or loose link lets the radiator sit at a different voltage from the taps. You feel that difference as a tingle or a shock.
- **A failed element in an electric rail:** An electric towel rail has a live element inside the metal case. A failed element leaks current onto that case. A loose earth core stops the RCD opening. An RCD is the safety switch that cuts power when current leaks to earth. The rail and any pipe joined to it stay live.
- **A leak from a shower circuit:** A faulty electric shower can leak onto pipework that also feeds a radiator. The radiator tingles in another room while the heating pipes themselves are sound. The RCD on that shower circuit may open at the same time.
- **A neutral touching earth:** A neutral touching an earth wire or a pipe puts voltage on bonded metal. The shock is stronger while a shower, immersion or kettle is running. It eases when that load is switched off.

## What can I check safely after a radiator shock?

You can note which other metals shocked you, read the fuse board through the closed cover, and switch an electric rail off at its wall switch.
- **Other metal that shocked you:** Recall whether a tap, the cooker or a towel rail shocked you in the same hour. Several metals doing that points to the supply earth or the main bond. Phone 105 and keep your hands off the pipes.
- **Switches you can see on the fuse board:** Look through the closed cover. Leave an RCD down if it opened after the shock. Reset nothing if the board is warm, buzzing, or smelling of burning.
- **The wall switch for an electric rail:** Switch off the wall switch or fused connection unit that feeds the towel rail. A fused connection unit is the small switch with a fuse in it. Leave the rail fixed to the wall.
- **Which appliance was running:** Write down whether the shower, the immersion or the towel rail was on when you felt the shock. That note shows which circuit to test first. A shock with every appliance off still needs a test.

## When should I book after a shock from a radiator?

Book Now after any shock from a radiator. Phone 105 as well when taps and other metal give the same shock.
- **You felt a clear shock:** A sharp shock means the radiator was at a dangerous voltage. Keep people away from that metal. Book Now so the bonding and the circuits are tested before the room is used again.
- **The tingle keeps returning:** A light tingle that returns with a shower or a heater is still voltage on the pipe. It can worsen into a hard shock. Leave the electric rail off at the wall switch and Book Now.
- **Taps give the same shock:** The same shock on a tap and a radiator points to the main bond or the supply earth. Phone 105 for the electricity network. Book Now and leave a tripped RCD switched off.

## What happens on a visit for a live radiator?

We measure the voltage on the radiator and the bonding first. We switch off the circuit that is raising it and test that circuit before a cover comes off.
- **What shocked you and what was on:** We ask which radiator you touched and whether a tap did the same. We ask which appliances were running. We read the fuse board with the cover on and switch off the electric rail circuit.
- **Readings on the pipe and the bond:** We measure voltage between the radiator and a sound earth. We measure the main bond back to the earth bar. Voltage that stays with the main switch off sits on the supply cable, so 105 is the network call.
- **The circuit that clears the voltage:** We open one breaker at a time until the voltage on the pipe falls. That breaker marks the leaking circuit. We then run an insulation test on the towel rail, shower or immersion that the readings name.
- **The bond, the isolation and the certificate:** We remake a loose bond when the readings show that link has failed. We leave a leaking heater circuit switched off. A minor works certificate follows a circuit we alter and names our NAPIT registration. A failed fuse board is given its own written price.

## What does a shock from a radiator cost?

The emergency price covers attendance, voltage tests on the radiator and the bonding, and leaving the failed circuit safe. Emergency electrician attendance is charged by the hour. A longer test, a part, a minor works certificate, or a later fuse board replacement changes the price and is written down before that extra work starts.
- Emergency electrician (out of hours): from £90 an hour
- A shock on every bonded pipe needs more tests than one electric towel rail.
- A breaker, bond or heater connection is fitted only when the tests name that part as failed.
- Fuse board replacement and an EICR are separate later jobs when the tests call for them.

## Questions about a shock from a radiator

### Is a tingle from a radiator dangerous?

Yes. A tingle is voltage on the metal, and the same fault can give a hard shock. Stay off the radiator and Book Now. Phone 105 if the taps tingle as well.

### Should I turn the heating off?

Switch an electric towel rail off at its wall switch. Leave the radiators alone and keep your hands off the metal. We test the circuit and the bonding that are putting voltage on the pipe.

### Will a new fuse board stop the shock?

A new fuse board goes in only when the tests show the board itself has failed. A sound board stays on the wall. Fuse board replacement then has its own written price.

### Do I get paperwork after the repair?

Altering a bond or a heater connection brings a minor works certificate. The certificate records the test results and our NAPIT registration. An EICR is a full inspection of the installation and is booked as its own job.

### Who do I phone if the taps shock me too?

Phone 105 when a tap gives the same shock as the radiator. That call reaches the electricity network about their supply cable. Book Now so we can test the bonding on the house side of the meter.

## Related problems
- [Brown marks on a socket or plug](https://lightingelectrical.co.uk/problems/scorch-marks-on-socket): Brown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- [Burning plastic smell from electrics](https://lightingelectrical.co.uk/problems/burning-plastic-smell-electrical): A burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- [Burning smell from a socket](https://lightingelectrical.co.uk/problems/burning-smell-from-socket): A burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- [Burning smell from the fuse box](https://lightingelectrical.co.uk/problems/burning-smell-from-fuse-box): A burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- [Electric shock from a light switch](https://lightingelectrical.co.uk/problems/electric-shock-from-light-switch): A shock from a light switch means the switch face is carrying current and that lighting circuit should be isolated.
- [Electric shock from the shower](https://lightingelectrical.co.uk/problems/electric-shock-from-shower): A shock from the shower means current is on the water, the case or the taps, so that circuit stays off until it is tested.

## Sources
- [IET: Broken PEN](https://electrical.theiet.org/wiring-matters/years/2021/84-march-2021/broken-pen/)
- [HSE: electrical injuries](https://www.hse.gov.uk/electricity/injuries.htm)
- [Electrical Safety First: first aid for electric shock](https://www.electricalsafetyfirst.org.uk/safety-advice/home-and-people/house-maintenance/first-aid/)
- [Call 105 for the local electricity network](https://www.powercut105.com/)

Updated 2026-11-16.

[Emergency electrician](https://lightingelectrical.co.uk/services/emergency-electrician)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)