# Electric shower tripping the electrics

> Electric shower tripping the electrics in Peterborough. Lighting Electrical tests the shower circuit and names the failed part before any repair.

An electric shower that trips the electrics is leaking current or overloading its own circuit. Lighting Electrical in Peterborough tests that circuit and names the failed part.

## Why does an electric shower trip the electrics?

The shower cuts the power when current leaves its circuit to earth, or when the heater asks for more current than the breaker allows. Other rooms go off when they share the safety switch that opened.
- **The heater inside the shower is leaking:** The heater is the part that warms the water. A crack lets water touch a live conductor. Current then leaks to earth and the safety switch opens. The trip often waits until the water runs hot, because heat opens the crack further.
- **Water in the ceiling switch or the cable:** The pull cord is the ceiling switch that cuts power to the shower. Steam or a slow drip wets the terminals in that switch, or the cable just above the ceiling. Wet insulation lets current leak to earth as soon as the shower is turned on.
- **The shower shares a safety switch with other circuits:** An RCD is the safety switch that opens when current leaks to earth. On many fuse boards one RCD feeds the shower and also the lights or the sockets. A leak on the shower opens that RCD. Those other circuits go off together.
- **Another circuit leaks and the shower shows it:** A large heater changes the current through a shared RCD. A neutral to earth fault on a different circuit can stay quiet until the shower starts. The RCD opens at that moment. The shower cable itself can still test sound.
- **The cable or breaker cannot carry the heater:** An electric shower needs its own cable and its own breaker. A breaker opens when current is too high. A shower tied onto a lighting or socket cable overloads that breaker. An RCBO is one device that combines the breaker and the RCD, so that circuit alone goes off.

## What can I check safely before I book?

You can watch the fuse board, the pull cord and any sign of water. Leave the shower case shut. Leave every screw in the fuse board.
- **When the power actually drops:** Switch the shower off at the pull cord and see whether the power stays on. Turn the pull cord on next, then start the shower. A trip at that moment points to a leak. A trip after the water runs hot points to the heater. Note which rooms went off.
- **Which switch has opened on the fuse board:** Look through the closed cover. The shower breaker sitting down, with the other switches up, means only the shower circuit opened. A wider switch with a test button sitting down is the RCD. It has taken every circuit it feeds. Leave the cover on.
- **One reset with the shower switched off:** If the board is cool, silent and free of any burning smell, switch the shower off and lift the open switch once. If it drops straight back, leave it down. Forcing it to stay up damages the switch and the cable.
- **Drips, stains and a wet pull cord:** Look at the ceiling under the bathroom, the pull cord, and the outside of the tray or screen. A brown stain or a drip means water is reaching the electric parts. Wipe the outside only. Do not open the shower or the switch.

## When should I book for a shower that trips the electrics?

Book Now when the shower knocks the power out again, the switch will not stay up, or you can see heat or water on the shower circuit.
- **The shower knocks the power out each time:** One reset has already failed with the shower off. The leak or the overload is still there. Another reset heats the switch. Leave the shower off and Book Now.
- **Heat, noise or a burning smell:** A warm pull cord, a buzz, or a burning smell at the fuse board means a joint is arcing. Arcing is a spark jumping across a loose terminal. Use the switch handle on the front of the board to leave that circuit off. Do not take the cover off.
- **Other rooms die when the shower starts:** Lights or sockets dropping with the shower mean a shared RCD has opened. The leak may be in the shower or on another circuit on that RCD. Leave the shower off until those circuits are tested apart. Book Now.
- **Water is reaching the switch or the ceiling:** A drip on the pull cord, or a wet patch on the ceiling, can put water across live parts. Leave the shower circuit off. Keep your hands off the wet switch. Book Now before anyone uses that shower again.

## What happens on a visit for a tripping shower?

We isolate the shower circuit, separate it from the other circuits, and name the failed part before anything is changed. Any repair waits until you accept it.
- **What tripped and which rooms went off:** We ask whether the trip is instant, after the water heats, or only with other appliances running. We read the fuse board with you and note the RCD or breaker that opened. The cover stays on until a tester shows the shower circuit is dead.
- **Tests that separate the shower from the rest:** We switch the shower circuit off. An insulation test checks whether the cable or the heater can leak current to earth. We then test the other circuits on that RCD, one at a time. The readings separate a failed heater, a wet joint, a damaged cable and a leak that is not in the shower.
- **The failed part, the earth path and the supply:** We name the failed part before we change it. Earthing is the path that carries fault current so the safety switch can open. Bonding joins metal pipes to that earth. We check both, and we check the supply can carry the shower load, before we write a price for any further work.
- **The repair and the certificate:** Once you accept the repair, we put right the joint, cable or device that failed. A failed heater is replaced under electric shower installation, priced on its own. Mira is one make we fit. We issue a minor works certificate when the circuit is altered, under our NAPIT registration. We leave the shower circuit off when it is unsafe to switch on.

## What does finding a tripping shower cost?

Electrical Fault Finding & Repair is charged by the hour. The price covers testing the shower circuit and the circuits that share its safety switch, the diagnosis we give you, and the start of the repair after you accept it. A slow leak along the cable takes longer than a heater that fails the test at once. A new part, a minor works certificate, a replacement shower or a fuse board change alters the price.
- Fault finding & repair: from £75 an hour
- A new breaker or RCBO from Hager, Wylex, Contactum, BG Electrical or MK Electric is added only when the test shows that device has failed.
- Electric shower installation is priced as its own job when the heater has failed and the fixed wiring tests sound.
- Fuse board replacement and emergency electrician attendance are each priced as separate jobs.

## Questions about a shower that trips the electrics

### Why do the lights go off when I turn the shower on?

The lights share an RCD with the shower. An RCD opens when current leaks to earth, and it takes every circuit it feeds. We test each of those circuits and name the one that is leaking.

### Should I keep resetting the switch so I can shower?

No. One reset with the shower off shows whether the switch will hold. If it opens again, leave it down. Repeated resets heat the terminals and can damage the cable and the RCD.

### Will you fit a new shower on the same visit?

Only when the tests show the heater has failed and you accept electric shower installation as its own job. A shower that tests sound stays in place. A failed joint, cable or breaker is repaired on the fault finding visit once you accept that work.

### What paperwork do I get after the repair?

Where we alter the circuit, we issue a minor works certificate. It records the tests for the work we finished and our NAPIT registration. An EICR is a separate inspection of the whole installation, not the record of this repair.

### Will a new fuse board stop the shower tripping?

We change the fuse board only when the RCD or the board fails its tests. A cracked heater or a wet pull cord still trips the power on a new board. Any board change is written as fuse board replacement after the shower tests.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)