Switch off at the fuse board if you can reach it safely, then leave the room. Lighting Electrical in Peterborough isolates the burnt circuit and names the failed part.

## Why does an electrical fire start at home?

An electrical fire starts when a loose joint, an overloaded cable or a failed appliance heats until the fitting or insulation burns.
- **A loose joint that arcs:** A loose screw at a socket, switch or light lets the conductors spark. That spark is arcing, and the heat chars the plastic until it smokes.
- **Too much load on one cable:** A breaker is the switch in the fuse board that guards one circuit. Heaters and extension leads piled on one socket circuit warm the cable until the insulation softens and smokes.
- **A board with no RCD:** An RCD is a safety switch that opens when current leaks away from the circuit. A fuse board fitted before RCDs were standard waits for a fuse to melt, so a leaking joint keeps heating.
- **A crushed flex or coiled lead:** A flex trapped under a rug or a coiled extension cannot shed heat. The insulation melts, the conductors touch, and the short sets the plastic alight.
- **Water across a live fitting:** Water on a socket, a light or an outside fitting bridges the contacts. Current then leaks to earth, the safety path back to the board, and the joint heats if the protective device stays closed.

## What can you check safely in an electrical fire?

You can get people out, look from a distance, and use a normal switch only when it is cool. Covers, flexes and fuse board screws stay untouched.
- **Everyone out of the room:** Leave the room where you see smoke, sparks or flames. Shut the door on the way out if you can do that without going back. Phone the fire service while you are outside.
- **The main switch if it is safe:** The main switch on the fuse board cuts every circuit. Use it only when the board is cool, quiet and free of smoke. If the board is hot or in smoke, leave it alone.
- **Heat, noise or brown marks:** Look from a distance for brown marks, a buzz, or a burning smell at a socket or a light. That circuit stays off. You do not touch the face, the screws or a melted plug.
- **Which breaker has opened:** With the cover still on, a breaker sitting down shows the circuit that opened. Leave it down after smoke or heat. A second reset pushes current back through the burnt joint.

## When should you book after an electrical fire?

Book Now when a socket, a light, a cable or the fuse board has smoked, sparked or smelt of burning, even after a breaker has opened.
- **Smoke, sparks or a burning smell:** The circuit that smoked stays switched off. Another reset can relight the joint. Book Now so we test the failed part before anyone uses that circuit.
- **A hot socket, switch or board:** Heat means the joint is still failing. On a cool board, use the breaker handle to leave that circuit off. Keep your hands off screws, covers and melted plastic.
- **Power returns after scorching:** Sockets or lights that work again after smoke still hide a charred joint. Leave that fitting unused. The circuit needs a test before it is put back into daily use.

## What happens on a visit after an electrical fire?

We isolate the burnt circuit first, test it dead, and name the failed part before any fitting or cable is changed.
- **The burnt circuit comes off:** We ask where the smoke or the smell started and which breaker opened. We read the fuse board with the cover on. We switch off that circuit, and we leave sound circuits on.
- **Dead tests name the failed part:** We prove the circuit is dead before a cover comes off. Tests on the dead cable show a short, a break or a leak to earth. Those readings separate a socket, a switch, a light, a breaker and a length of cable.
- **The repair after you accept it:** We name the failed part before we change anything. A sound fitting stays closed. A repair that changes the circuit is recorded on a minor works certificate with our NAPIT registration.
- **Earthing and bonding before a later price:** Earthing is the path that carries fault current so a breaker can open. Bonding joins metal pipes to that earth. We check both, and whether the supply can feed the load, before we price any later work.

## What does an electrical fire visit cost?

The time spent isolating and testing the burnt circuit sets the price. That time covers attendance, the dead tests, and naming the failed part. A replacement fitting, a minor works certificate, or a later fuse board replacement changes the price.
- Emergency electrician (out of hours): from £90 an hour
- A scorched socket takes less time to trace than burnt cable buried in a wall.
- We fit a socket, switch, breaker or cable only after the tests show that part has failed.
- Fuse board replacement is written up separately when the board itself has failed.

## Questions about an electrical fire at home

### Should I put water on an electrical fire?

No. Water carries current from a live circuit to a person who touches it. Use the main switch only when the fuse board is cool, quiet and free of smoke, then leave the room. We test the circuit before it is used again.

### Can I reset the breaker after the smoke stops?

No. Switching it back on sends current through the burnt joint. Leave the breaker off and leave the fitting unused. We name the failed part from the tests before that circuit is switched on.

### Will you replace the fuse board on the same visit?

Only when the tests show the board has burnt and you accept a separate written price for fuse board replacement. A burnt socket or switch is repaired on its own. A board that tests sound stays in place.

### What paperwork follows an electrical fire repair?

A minor works certificate records the tests when the repair changes the circuit, and it carries our NAPIT registration. If we isolate the circuit and change nothing, we write down the readings and the failed part. An Electrical Installation Condition Report, an EICR, is a separate inspection of the whole installation.

## Related problems
- [Brown marks on a socket or plug](https://lightingelectrical.co.uk/problems/scorch-marks-on-socket): Brown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- [Burning plastic smell from electrics](https://lightingelectrical.co.uk/problems/burning-plastic-smell-electrical): A burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- [Burning smell from a socket](https://lightingelectrical.co.uk/problems/burning-smell-from-socket): A burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- [Burning smell from the fuse box](https://lightingelectrical.co.uk/problems/burning-smell-from-fuse-box): A burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- [Electric shock from a light switch](https://lightingelectrical.co.uk/problems/electric-shock-from-light-switch): A shock from a light switch means the switch face is carrying current and that lighting circuit should be isolated.
- [Electric shock from the shower](https://lightingelectrical.co.uk/problems/electric-shock-from-shower): A shock from the shower means current is on the water, the case or the taps, so that circuit stays off until it is tested.

## Sources
- [HSE: Electrical Safety at Work](https://www.hse.gov.uk/electricity/)
- [Electrical Safety First: Electric Shock First Aid](https://www.electricalsafetyfirst.org.uk/safety-advice/home-and-people/house-maintenance/first-aid/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)

Updated 2026-11-16.

[Emergency electrician](https://lightingelectrical.co.uk/services/emergency-electrician)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)