title: "Electrics trip when I plug something in | 4.7 Star · NAPIT · From £60"
description: "Electrics trip when you plug something in around Peterborough. Lighting Electrical tests the appliance, socket and circuit and names what opened the…"
canonical: "https://lightingelectrical.co.uk/problems/electrics-trip-when-i-plug-something-in"
---

# Electrics trip when I plug something in

> Electrics trip when you plug something in around Peterborough. Lighting Electrical tests the appliance, socket and circuit and names what opened the…

A plug that trips the power means the appliance, the socket or the circuit has a fault. Lighting Electrical in Peterborough tests the switch that opened and names the failed part.

## Why do the electrics trip when I plug something in?

The power trips because the plug has added a fault or a load the circuit cannot hold. The switch opens to cut that circuit.
- **A faulty appliance leaking to earth:** An RCD is a switch that opens when current leaks from the circuit to earth. An RCBO is that same protection built into the breaker for one circuit. A damaged kettle, heater or charger leaks as soon as the plug goes in or the appliance is switched on, and that device opens.
- **Too much load on the socket circuit:** A breaker opens when the circuit draws more current than its rating. A heater and a kettle on the same sockets can already sit near that limit. One more plug is enough to open the breaker while the other circuits stay on.
- **A damaged plug or a scorched socket:** Bent pins, a cracked plug or brown marks around the pin holes make a short as the plug goes in. The breaker or the RCD opens at once. The socket can still feel warm after the plug is out.
- **Neutral and earth joined under load:** Current from the appliance returns on the earth as well as the neutral when those two are joined on the circuit. The RCD sees the imbalance and opens. Lights and sockets that share that RCD go off together.
- **Damp in a socket you have just used:** Water across the contacts of a kitchen socket or an outside socket leaks to earth when a plug is pushed in. The RCD opens straight away. Leave that socket empty, and leave the circuit switch off if it will not hold.

## What can I check safely when a plug trips the power?

You can pull the plug, read the fuse board through the closed cover, and try one lamp you already trust. Every screw stays in.
- **Which switch has dropped:** Look through the closed fuse board cover and note whether one breaker is down or a wider RCD has taken several circuits off. Leave the cover screws alone. Reset once only while the board is cool, quiet and free of a burning smell.
- **The same appliance on a live socket:** Unplug the item that tripped the power. If another circuit stayed on, plug that item into one socket on the live circuit. If that circuit trips too, the appliance is the fault. If it runs, the first socket or its cable needs a test. Unplug it again either way.
- **A lamp in the socket that tripped:** With the suspect appliance unplugged, put in a lamp that already works in another room. A lamp that stays lit means the circuit held without that appliance. A lamp that goes out at once means the fault is still on the wiring or the socket.
- **Warm plastic, a buzz or brown marks:** A warm socket, a buzz or brown stains at the pin holes means a joint is failing. Stop using that socket. Use the breaker handle to leave the circuit off. Do not open the socket or the appliance.

## When should I book if a plug keeps tripping the power?

Book Now when another plug still trips the power, the switch will not hold, or a socket is hot or smells of burning.
- **The switch drops with every appliance out:** Everything on that circuit is unplugged and the breaker or RCD still opens. The fault is in the cable, a socket or the device that guards the circuit. Leave the switch off. Resetting again warms the breaker and the cable.
- **Ordinary plugs all open the same switch:** A lamp and a charger both open the same switch. The fault sits on the circuit, not in one appliance. Leave that switch off until the circuit is tested.
- **The socket smells of burning:** A warm socket, a buzz or a smell of burning means the joint is arcing. Arcing is a spark across a loose connection. Switch that circuit off at the breaker handle and keep the socket shut.
- **The trip takes out more than one room:** An RCD that feeds several circuits opens, so the lights go off with the sockets. The pattern is wider than one appliance. Book Now so that shared device and each circuit on it can be tested.

## What happens on a visit for a plug that trips the power?

We start with the plug you used and the switch that opened, then test that circuit before any part is changed.
- **The plug and the switch that opened:** We ask which appliance you plugged in, when the trip started, and which rooms went off. We look at the fuse board with you and note the breaker or RCD that dropped. The cover stays on until a tester shows the circuit is dead.
- **Tests that separate the appliance from the wiring:** We isolate the circuit that tripped. We test the appliance flex and the socket wiring apart from each other. The readings point to a failed appliance, a damaged socket, a leaking cable, or a breaker or RCD that has opened.
- **The failed part named before a repair:** You hear the failed part by name before we fit anything. On the visit we confirm the earth path, the bonds to metal pipes, and whether the supply can feed the load. Earthing is the path that lets fault current open the switch. Bonding joins the pipes to that earth. A socket that tests sound stays on the wall.
- **The repair and the certificate:** The repair of that finding goes ahead after you accept it. We test the circuit again once the work is done. Where the circuit was altered, we issue a minor works certificate showing our NAPIT registration. If the circuit cannot be left live, its switch stays off and the other circuits stay on.

## What does tracing a plug trip cost?

Electrical Fault Finding & Repair is charged by the hour. That price covers the tests on the circuit the plug tripped, the diagnosis we give you, and the start of the repair after you accept it. More time on a leak that shows only under load, a part that has failed, or a minor works certificate changes the price. Fuse board replacement and Emergency electrician attendance are separate jobs.
- Fault finding & repair: from £75 an hour
- An appliance that trips at once takes less time to separate than a leak that appears only when a load is connected.
- A socket, breaker or cable is fitted only after the tests show it has failed, including Hager, Wylex, Contactum, BG Electrical and MK Electric.
- A minor works certificate changes the price when the repair alters the circuit. An EICR, the report on the whole installation, stays a separate inspection.

## Questions about a plug that trips the power

### Is it my appliance or the house wiring?

We test the appliance on its own and then test the circuit with it unplugged. A leak or a short in the appliance leaves the circuit fit to switch on once that appliance is out. Readings in the socket or the cable name that part before we repair it.

### Should I keep resetting the switch?

One reset is enough, and only while the fuse board is cool, quiet and free of a burning smell. If the switch opens again, leave it off. Resetting again warms the breaker and the cable.

### Will you change the fuse board because a plug trips?

A new fuse board goes in only when the tests show the board or the device that opened has failed. A faulty appliance or a damaged socket is a repair to that part. Any board change is quoted separately after the tests.

### Do I get paperwork after the repair?

A minor works certificate follows when the repair alters the circuit. It lists the test results for that alteration and shows our NAPIT registration. An Electrical Installation Condition Report, an EICR, is a separate inspection of the whole installation and is booked as its own visit.

### Will other rooms stay on during the test?

Other rooms stay on because we switch off only the breaker or RCD your plug opened. We switch that device on again after a repair you accept. A circuit that still fails the tests stays off.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [IET: BS 7671 Guidance Publications](https://electrical.theiet.org/guidance-and-codes-of-practice/publications-by-category/bs-7671-and-guidance/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)