A home charger that will not charge has stopped at the car, the charge point or the dedicated circuit. Lighting Electrical in Peterborough tests that circuit and names the failed part.

## Why is my home charger not charging?

A home charger stops because the car refuses the session, the charge point locks out, or the dedicated circuit opens. The house lights can stay on while that one circuit is dead.
- **The car will not accept a charge:** The car can block a session with a charge timer, a battery limit or a plug lock. The charge point can still have power. We read the car state before we test the house circuit.
- **The charger breaker has opened:** The charger has its own circuit in the fuse board. A breaker opens when that circuit draws too much current. An RCD opens when current leaks to earth. An RCBO is one device that does both. When it opens, the charger goes dead and other circuits stay on.
- **The charge point has stopped the session:** Ohme, myenergi, Hypervolt and Andersen charge points stop a session when their earth check fails or the house load is already high. Earthing is the path that carries fault current away from you. The unit can sit quiet while the car and the other circuits are sound.
- **The lead or the plug is not making a circuit:** A tethered lead is fixed to the charge point. A bent pin, water on the plug, or a plug that is not fully home stops the session starting. A loose cable in a weatherproof socket stops it the same way.
- **The supply has no room for the charger:** A charger asks for a large steady current. The breaker opens, or the charge point pauses, when the supply is already near its limit. Bonding links metalwork and the charger earth back to the fuse board. We check earthing, bonding and that spare capacity before we price any further work. The age of the house does not settle those tests.

## What can I check safely before anyone opens the charger?

You can read the car, seat the plug and look at the fuse board with the cover left on. You do not open the charge point, the fuse board or any joint.
- **What the car says about the charge:** Open the car screen and read any charge limit or timer. A limit of zero or a timer that is still waiting looks like a dead charger. Leave the charge point cover shut while you read it.
- **The plug on the tethered lead:** Push the plug fully into the car until it locks. Look for water, dirt or a bent pin on the outside of the plug only. Dry the outside with a cloth if it is wet. Do not unscrew the charge point or the socket.
- **The breaker with the cover shut:** Find the switch named for the charger and read it through the closed cover. If it is down, the board is cool and there is no burning smell, one reset is reasonable. If it opens again at once, leave that switch down.
- **Whether the rest of the house is on:** Turn a light on in another room and try a socket with a lamp you already trust. Power in the house with a dead charger means the dedicated circuit or the charge point has stopped. A dark house is a wider loss of supply.

## When should I book for a charger that will not charge?

Book Now when one reset fails, the charge point or the fuse board is hot or smells of burning, or the car charges elsewhere and still will not charge at home.
- **The charger switch will not stay up:** The plug is seated and the switch opens again at once. The fault is in the charge point, the dedicated cable or the protective device. Another reset heats the terminals, so leave that switch down.
- **Heat, a buzz or a burning smell:** A warm charge point, a buzz or a smell of burning means a joint is failing. Switch the charger circuit off at the breaker handle. Keep your hands off the cover screws and the lead pins.
- **The car charges away from home:** A car that charges on another charger and refuses this one points to the home charge point or its circuit. Book Now rather than repeating resets on a dead session.
- **Water in the plug or the enclosure:** Rain in the plug or in the outdoor enclosure lets current leak to earth. Leave the charger switch off. Wipe only the outside of the plug. Book Now before the next attempt to charge.

## What happens on a visit for a charger that will not charge?

We start with the car and the fuse board, then test the dedicated circuit and name the failed part before anything is changed. A repair waits until you accept it.
- **What the car and the charger did:** We ask when the charger last finished a session and what the car showed. We look at the tethered lead, the weatherproof socket and the fuse board beside you. The cover stays on until a tester shows the charger circuit is dead.
- **Tests on the dedicated circuit:** We switch off the charger circuit. A dead test measures the cable while it is off. The readings show a short, a break or a leak to earth. They also separate a failed RCBO from a failed charge point.
- **Earthing, bonding and spare capacity:** We tell you whether the car, the charge point, the cable or the protective device failed. We check earthing and bonding on the visit. We also check whether the supply will carry the charger before we write any further price.
- **The repair and the paperwork:** The repair of the failed joint, breaker or cable goes ahead after you accept it. We repeat the tests after that repair. Where the charger circuit is altered, a minor works certificate records the results and our NAPIT registration. A failed charge point is priced as EV charger installation, which is its own job. If the circuit is unsafe to put back on, we leave the charger switch off.

## What does a charger fault visit cost?

The time spent tracing a charger that will not charge sets the price. That time covers the tests, the spoken diagnosis and the start of the repair once you accept it. A charge point that has failed is priced as EV charger installation. A minor works certificate, a replacement breaker or a fuse board replacement changes the price.
- Fault finding & repair: from £75 an hour
- A longer test on the dedicated cable takes more time than reading a car timer that was blocking the session.
- We fit a breaker, a length of cable or a charge point from Ohme, myenergi, Hypervolt or Andersen only after the tests show it has failed.
- Fuse board replacement and emergency electrician attendance are each priced as their own jobs.

## Questions about a home charger that will not charge

### Will you change the charge point before you know the cause?

No. The tests come first and we name the failed car setting, charge point, cable or protective device. Any repair starts after you accept that finding. A sound charge point stays where it is.

### Can the rest of the house stay on while you test?

Yes. We switch off only the charger circuit and leave every healthy circuit on. That charger circuit goes back on after a repair you have accepted. It stays off if the readings say it cannot be left live.

### What paperwork do I get after a charger repair?

Where we alter the charger circuit, a minor works certificate records the tests for that job and shows our NAPIT registration. If we only isolate the circuit and change nothing, you still get the readings and the name of the failed part. An EICR inspects the whole installation and is booked as its own job.

### Will a new fuse board make the charger work?

Only when the tests show the fuse board or the charger protective device has failed. A sound board stays in place if the fault is the car, the charge point or the cable. A new fuse board waits for a separate price after the charger tests are done.

### What if my car charges elsewhere but not on this charger?

A car that charges on another unit and refuses this one has a fault in this charge point or its dedicated circuit. We test both and name which one has failed. The car stays out of the repair when its own checks are clear.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [IET: Code of Practice for Electric Vehicle Charging](https://electrical.theiet.org/guidance-and-codes-of-practice/publications-by-category/electric-vehicles/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [NICEIC: Householder Guidance](https://niceic.com/householders/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)