# EV charger trips the electrics

> EV charger trips in Peterborough open a safety switch that can cut lights and sockets. Lighting Electrical tests the charger circuit and names the device.

When an EV charger trips the electrics, a safety switch has opened and taken other circuits with the charger. Lighting Electrical in Peterborough tests that circuit and names the switch that opened.

## Why does an EV charger trip the electrics?

Charging opens a safety switch because current leaks to earth, the switch also feeds other circuits, or the charger draws more than that switch allows.
- **The charger shares a safety switch:** An RCD is a switch that turns off when current leaks to earth. Earth is the path that carries a fault away from you. If the charge point sits on the same RCD as the sockets or the lights, leakage from the car plus those circuits can open that RCD. Every circuit on it goes off together.
- **One safety switch covers the whole fuse board:** Some fuse boards use one RCD as the main switch. Leakage from the charge point, the lead or the car opens that switch. Power goes off across the board at the same time. A charger on its own device would stop the charger only.
- **Direct current from the car opens the protection:** A home charge point must deal with direct current that a car can put on the earth path. A device inside the charger opens the output if that current passes 6 milliamps. Charging stops when that device opens. A Type AC switch on the fuse board is the wrong type for a charge point.
- **Rain has got into the outdoor charge point:** A tethered charger on an outside wall can let rain in at the lead entry or the casing. Water across the terminals lets current leak to earth. The RCD or the RCBO then opens. An RCBO is one device that acts as the breaker and the RCD for a single circuit.
- **The car or the charging lead is leaking:** The switch opens when this car is plugged in and holds when the lead is off the car. The leak can sit in the tethered lead, the inlet on the car, or the charger built into the car. The house cable can test sound while that car still opens the switch.
- **The charger is drawing more than the breaker allows:** A breaker opens when a circuit draws too much current. A home charge point can run for hours at a high steady load. If that load is set above the breaker, the breaker opens and charging stops. Circuits on other breakers stay on.

## What can I check safely if the EV charger trips?

You can read the fuse board through the closed cover, stop the charge, and reset one switch if the board is cool and quiet. Leave the charger casing shut.
- **Which parts of the house went off:** Note whether only the charger stopped, or the lights and sockets went off with it. Only the charger stopping points to its own breaker or RCBO. Half the board, or the whole board, points to an RCD that feeds more than the charger.
- **Which switch is sitting down:** Look through the closed fuse board cover. A switch sitting down is the one that opened. Read any name beside it, such as the charger or the sockets. Leave every screw in place.
- **Stop the charge and reset once:** End the charge in the car or in the charger app, and unplug the lead if it comes off the car. If the board is cool, quiet and free of a burning smell, lift the open switch once. If it drops straight away, leave it off.
- **Rain, cracks or a hot casing you can see:** Look at the outside of the charge point and the lead without taking the cover off. A wet casing, a cracked gland or a warm front means leave the charger switch off. Keep your hands off the lead if it is damaged or sitting in water.

## When should I book for an EV charger that trips?

Book Now when one reset will not hold, when charging cuts other circuits, or when the charger or the fuse board is hot, wet or smelling of burning.
- **The switch drops again as charging starts:** The lead is off the car, or the car is plugged in, and the switch opens at once. The fault is still in the charger circuit, the charge point or the car. Another reset heats the switch and the cable, so leave it off.
- **Charging cuts the lights or the sockets:** The charger is taking other circuits off with it. Those circuits need a test before the next charge. Leave the open switch where it is and Book Now.
- **Heat, a buzz or a burning smell:** A warm charge point, a buzz, or a burning smell at the charger or the fuse board means a joint is failing. Use the switch handle on the front of the board to turn that circuit off. Keep clear of the casing screws.
- **The trip comes with rain on the charger:** Water in an outdoor charge point leaks current to earth and holds the switch open. Leave that switch off. Keep the lead out of puddles and Book Now before the car is plugged in again.

## What happens on a visit for a tripping EV charger?

We start at the fuse board, test the charger circuit with it switched off, and name the failed part before we fit anything.
- **When the trip happens and which switch opened:** We ask whether the trip comes as the lead is connected, after a long charge, or in the rain, and whether one car does it. We look at the fuse board with you and note the switch that opened. No cover comes off until a tester shows that circuit is dead.
- **Tests on the charger circuit:** We switch the charger circuit off at its device. A dead test checks the cable for a break, a short and current leaking to earth. We also test how the RCD or RCBO trips. The readings separate the charge point, the lead, the car and the protective device.
- **Earthing, bonding and room on the supply:** We measure the earth path that lets a safety switch open, and the links from the fuse board to the metal pipework. We measure whether the incoming supply can feed the charger as well as the other circuits. Any further price follows those readings.
- **The repair and the certificate:** We tell you the failed part and fit it only after you approve that repair. We test the circuit again afterwards. Where the charger circuit was altered, a minor works certificate records the tests under our NAPIT registration. If the circuit is unsafe to put back on, we leave its switch off.

## What does an EV charger trip visit cost?

Electrical Fault Finding & Repair is charged by the hour. The price covers the tests on the charger circuit, the diagnosis we give you, and the start of the repair after you approve it. A longer test, a replacement part, or a minor works certificate changes the price. A new charge point or a fuse board change is written up as its own job.
- Fault finding & repair: from £75 an hour
- A trip that cuts the whole board takes longer to trace than a charger that stops on its own device.
- An RCBO, a lead, or a charge point from Ohme, myenergi, Hypervolt or Andersen is added only when the tests show it has failed.
- Fuse board replacement and EV charger installation are separate written jobs when the tests point to them.

## Questions about an EV charger tripping the electrics

### Will the rest of the house stay on while you test?

Yes. We switch off the charger circuit for the tests and leave every other circuit on. We put the charger circuit back on only when it can be left live.

### Do you change the charger before you know the cause?

No. We name the failed switch, lead, joint or charge point before any repair. EV charger installation is a separate job when the unit itself has failed.

### Will a new fuse board stop the charger cutting the house?

Only when the tests show the board, or the safety switch inside it, is the part that opens. A leaking lead or a wet charge point still trips a new board. Fuse board replacement has its own written price after those tests.

### What paperwork do I get after the repair?

Where we alter the charger circuit, the minor works certificate lists the tests and our NAPIT registration. If we change nothing and only leave the circuit off, we write down the readings and the failed part. An EICR is a separate inspection of the whole installation.

### What if my car is what makes the switch trip?

We test the house cable and the charge point with the car unplugged. If the switch opens only when this car is connected, the leak is in the car or its inlet. That car stays unplugged until a vehicle workshop checks it.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [IET: Code of Practice for Electric Vehicle Charging](https://electrical.theiet.org/guidance-and-codes-of-practice/publications-by-category/electric-vehicles/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)