title: "Exposed electrical wires in the house | 4.7 Star · NAPIT · From £60"
description: "Exposed wires in Peterborough leave bare copper where someone can touch it. Lighting Electrical isolates the circuit and tests the cable before repair."
canonical: "https://lightingelectrical.co.uk/problems/exposed-wires"
---

# Exposed electrical wires in the house

> Exposed wires in Peterborough leave bare copper where someone can touch it. Lighting Electrical isolates the circuit and tests the cable before repair.

Exposed wires in the house leave copper open where a person can touch it. Lighting Electrical in Peterborough isolates that circuit and tests the cable before any repair.

## Why are wires exposed in the house?

Wires show bare copper when the sheath or the coloured core insulation has split, been cut, or come off a joint.
- **Old insulation has cracked:** Older lighting cable used rubber or fabric around the copper. That covering dries, cracks and falls away in a loft or above a ceiling. We test the cable because the age of the house does not tell us it is sound.
- **A cut or a nail through the sheath:** A picture fixing, a floorboard nail or a saw can slice the sheath in one place. The copper shows at the cut. The cable on either side can still look whole.
- **A joint left out of an enclosure:** A joint connects two or more cables. Conductors left outside a closed box stay bare. The same thing happens when a back box is too shallow and the cores push past the socket or the switch.
- **Worn flex on a light or an appliance:** A pendant is a light hung on flexible cord. Rubbing at the ceiling rose wears that cord through. Chewing in a loft does the same. The coloured cores then hang where a hand can meet them.
- **Heat or water has opened the sheath:** Heat from a hot lamp, or water running along a cable, cracks the plastic sheath. Sun on an outdoor cable does the same over time. Once the sheath has split, the copper is open.

## What can I check without touching exposed wires?

You can look from a safe distance and use the fuse board only when your hand stays clear of the bare copper.
- **Which room and which fitting:** Note the room and the fitting where the copper shows. A ceiling rose, a socket, a loft cable and a pendant flex are different repairs. Stand where nothing you wear can brush the copper.
- **The breaker, if you can reach it safely:** A breaker is the switch on the fuse board that guards one circuit. If the board is in another room and the cover is closed, switch off the breaker for that room and leave it off. If the bare copper is next to the board, stay back and Book Now.
- **Whether the cable still looks live:** Lights still on along that cable, a buzz, or a smell of burning mean you treat the copper as live. Do not cover it with tape. Do not push the cores back into the wall or the rose.
- **Who and what is near the cable:** Keep children and pets out of the room. Keep water and metal tools away from the copper. Leave furniture where it is if moving it would touch the wire.

## When should I book for exposed wires?

Book Now as soon as copper is visible, including when the lights still work and the fuse board is cool and quiet.
- **You can see copper:** Visible copper on a cable, in a rose or behind a loose socket is enough. You do not need a burning smell or a dead circuit first. Switch that circuit off only if you can do it without touching the copper, then Book Now.
- **Someone felt a shock, or the spot is hot:** A shock, browning or heat at the break means current has already left the cable. Leave the circuit off. Keep people away from the spot until the circuit is isolated.
- **The damage is in a loft, a floor or outdoors:** A chewed length, a nicked sheath or a split outdoor cable can stay live out of sight. Do not cover the copper with a board, a cloth or tape. Book Now so the circuit can be isolated and tested.

## What happens on a visit for exposed wires?

We make the damaged cable dead, test it, and tell you the repair before any new part is fitted.
- **Isolate the circuit with the bare copper:** We ask where the copper is and whether a breaker is already off. We prove the cable is dead with a tester before we touch it. Circuits that test sound stay on.
- **Test the damaged cable:** With the circuit dead, a continuity test shows whether the copper still runs end to end. An insulation test shows whether current leaks between cores or to earth. Earth is the path that lets fault current flow away from a person. Those readings separate one nicked spot from a longer failed run.
- **Repair only the part that failed:** We tell you the result before a part is changed. A sound joint goes into a closed enclosure. A failed length is replaced after you say yes. A fitting from MK Electric, BG Electrical or Varilight goes on only when that fitting is damaged. An open or failed consumer unit from Hager, Wylex or Contactum is priced as Fuse board replacement, not as this repair.
- **Certificate, earthing and the next price:** If we alter the circuit we write a minor works certificate with our NAPIT registration on it. Before a further price we check earthing, bonding and whether the supply can feed another load. Bonding joins metal pipes and other metalwork to the earth at the fuse board.

## What does repairing exposed wires cost?

The price follows the time taken to isolate the cable, test it and complete the repair you have accepted. That price includes the diagnosis we give you on the visit. Replacing a short damaged end takes less time than a longer run through a loft or under a floor. A replacement fitting, a minor works certificate, or Fuse board replacement written as its own job, changes the price.
- Emergency electrician (out of hours): from £90 an hour
- We fit a socket, a switch, a ceiling rose or a length of cable only when the tests show that part has failed.
- Fuse board replacement has its own written price when the consumer unit is open or has failed.
- Emergency electrician is a separate charge from Electrical Fault Finding & Repair.

## Questions about exposed wires

### Can I wrap tape around the bare copper?

No. Tape only hides the copper and leaves the insulation missing. Switch the circuit off if you can do that without touching the cores. Book Now and keep clear of the cable.

### Will the repair be finished on the same visit?

We name the failed length, joint or fitting before anything new is fitted. That repair goes ahead on the visit after you say yes to it. Fuse board replacement and House Rewiring are priced as their own jobs.

### What certificate do I get?

A minor works certificate is issued when the repair changes the circuit. It lists the test results for that job and shows our NAPIT registration. An EICR inspects the whole installation and is booked separately.

### Should the whole circuit be rewired?

Not from the look of one bare spot. The tests show whether the fault is a single cut, a joint, or insulation that has failed along the run. House Rewiring is quoted only when those tests show the rest of the circuit insulation has failed.

### What if I already had a shock from the wire?

Stay away from the cable. If that breaker is already off, leave it off. We isolate and test the circuit that gave the shock before we repair it, and we leave healthy circuits switched on.

## Related problems
- [Brown marks on a socket or plug](https://lightingelectrical.co.uk/problems/scorch-marks-on-socket): Brown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- [Burning plastic smell from electrics](https://lightingelectrical.co.uk/problems/burning-plastic-smell-electrical): A burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- [Burning smell from a socket](https://lightingelectrical.co.uk/problems/burning-smell-from-socket): A burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- [Burning smell from the fuse box](https://lightingelectrical.co.uk/problems/burning-smell-from-fuse-box): A burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- [Electric shock from a light switch](https://lightingelectrical.co.uk/problems/electric-shock-from-light-switch): A shock from a light switch means the switch face is carrying current and that lighting circuit should be isolated.
- [Electric shock from the shower](https://lightingelectrical.co.uk/problems/electric-shock-from-shower): A shock from the shower means current is on the water, the case or the taps, so that circuit stays off until it is tested.

## Sources
- [HSE: Electrical Safety at Work](https://www.hse.gov.uk/electricity/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [HSE: Electrical Injuries](https://www.hse.gov.uk/electricity/injuries.htm)

Updated 2026-11-16.

[Emergency electrician](https://lightingelectrical.co.uk/services/emergency-electrician)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)