# Bathroom fan stopped working

> Bathroom fan stopped working in Peterborough: Lighting Electrical tests the circuit and replaces the fan when it is sound, with paperwork.

A bathroom fan that has stopped working has lost its supply, seized in the damp, or failed at the switch. Lighting Electrical in Peterborough tests the fan circuit and fits a new fan when that circuit is sound.

## Why has the extractor fan stopped working?

The fan stops because the motor has seized, the switch is off, or the circuit that feeds it has opened. Steam from a shower or a hob is what wears the motor out.
- **A motor seized by steam:** Steam and grease coat the blades and the bearings. The motor then hums or stays silent, and no air leaves the room. That fan is replaced once its circuit tests sound.
- **A fused spur or pull cord that is off:** A fused spur is a switched supply with its own fuse, often sited outside the bathroom. With that switch off, or with a failed pull cord, the fan is dead while the room light can stay lit.
- **The lighting circuit has opened:** Many bathroom fans take their power from the lighting circuit. When that breaker opens, the fan and the room light go off together. A fan fed by its own fused spur can stop while the light stays lit.
- **A failed overrun timer:** An overrun timer keeps the fan going for a short time after the light is switched off. A failed timer means the fan never starts, or it runs only while the light is on.
- **A blocked grille or a stuck shutter:** Dust packed into the grille stops the airflow even when the blades turn. A backdraught shutter is the flap that shuts when the fan is off, and a stuck flap does the same. The room stays full of steam.

## What can you check safely on a stopped fan?

You can try the switches, listen at the grille and see if the room light works. Do not take the fan apart, do not open the fuse board, and do not touch a cable.
- **The pull cord and the wall switch:** Pull the cord once and turn the wall switch on. If the fan starts, it had been switched off. If it stays still, the motor or the circuit needs a test.
- **The fused spur outside the room:** Find the fan switch above the door or in a cupboard nearby. Turn it on if it is off. If it is already on, leave the fuse inside untouched.
- **The light in the same room:** Turn the bathroom or kitchen light on. A dead light as well as a dead fan points to the lighting circuit that feeds both. A live light with a dead fan points to the fan, the spur or the timer.
- **A hum and the outside of the grille:** Listen under the fan. A hum with no air means the motor is powered but not turning. Silence means no supply or a dead motor. Wipe the outside of the grille only.

## When should you book for a stopped extractor fan?

Book Now when the switches are already on and the fan still does not run, or when it hums, smells hot or knocks the light off. Steam will keep sitting on the walls while it stays dead.
- **The fan stays dead with the switches on:** The pull cord and the fused spur are on and the fan does nothing. The fault sits in the motor, the timer or the wiring. Switching it again will not free a seized motor.
- **A hum, a rattle or a hot smell:** A hum, a rattle or a smell of heat means the motor is failing. Turn the fan off at the wall switch or the fused spur. Leave every cover screw where it is.
- **The light goes off with the fan:** The room light drops out when the fan should start, or the breaker will not hold. The fault is on the circuit that feeds both. Leave that breaker off when it opens again.

## What happens on an extractor fan visit?

We switch off the fan circuit, test it, and fit a new fan when the circuit is sound. Anything on another breaker keeps its power.
- **The room and the dead circuit:** We ask which room lost the fan and whether its light still works. Only the fan circuit is switched off. A tester shows that circuit is dead before the old fan is removed.
- **Tests before a new fan goes up:** We test the cable at the fan for a break and for current leaking to earth. The earth path is the way a fault current returns to the fuse board. We also test pipe bonding and spare capacity on the supply before any price past the fan itself. Pipe bonding joins a metal bath or pipe to that earth path.
- **Fitting the replacement fan:** The old fan comes off and the new fan goes on the same opening. We connect the live, the neutral and the earth, and we set the duct so air leaves the room. A longer cable or a new duct waits until you accept the written price.
- **Air test and the paperwork:** We switch the fan on and check that it pulls air out of the room. You keep the electrical paperwork for the fitting. A minor works certificate is included when that is the record the job needs, and it carries our NAPIT registration.

## What does a stopped extractor fan cost to put right?

The price covers a standard extractor fan on a cable and a duct path that are already in place, the connection to the lighting circuit or a fused spur, a test that the fan runs and pulls air, and the electrical paperwork for that fitting. Extra cable, new ducting, a timer switch or harder access changes the price, and we write the price down before any work starts. When the circuit cannot feed the fan, a new fuse board is priced as its own job.
- Extractor fan installation: from £180
- The written price is for a fan where the cable and the duct path are already in place.
- A timer switch, extra cable, new ducting or harder access is added to the written price before we start.
- A new fuse board is a separate job when tests show the circuit cannot feed the fan.

## Questions about a stopped extractor fan

### Will my lights go off while the fan is being fitted?

Only the circuit that feeds the fan is switched off while we work. A light or a socket on another breaker keeps running. We put the fan circuit back on after the air test.

### Can you replace a noisy fan or one that is completely dead?

Yes. We change a noisy or dead extractor fan when its circuit tests sound, then check that air leaves the room. Any new cable or ducting is priced in writing before that extra work starts.

### Do I get paperwork after an extractor fan is fitted?

You get the electrical paperwork the fitting needs when the work is finished. A minor works certificate is the record when the job calls for one, and it lists the tests and our NAPIT registration. You keep that record for the property.

### Do you fit extractor fans in kitchens and business washrooms?

Yes. We fit extractor fans for homeowners, landlords and businesses. The room can be a kitchen, a bathroom, a utility room or a washroom at a workplace.

## Related problems
- [Aluminium wiring in the house](https://lightingelectrical.co.uk/problems/aluminium-wiring): Aluminium cable overheats at loose joints. We test it, write the electrical installation condition report, and price any copper replacement separately.
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Brown marks on a socket or plug](https://lightingelectrical.co.uk/problems/scorch-marks-on-socket): Brown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- [Burning plastic smell from electrics](https://lightingelectrical.co.uk/problems/burning-plastic-smell-electrical): A burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- [Burning smell from a socket](https://lightingelectrical.co.uk/problems/burning-smell-from-socket): A burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- [Burning smell from the fuse box](https://lightingelectrical.co.uk/problems/burning-smell-from-fuse-box): A burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [NICEIC: Householder Guidance](https://niceic.com/householders/)

Updated 2026-11-16.