title: "Immersion heater no hot water | 4.7 Star · NAPIT approved · From £60"
description: "Immersion heater no hot water in Peterborough. Lighting Electrical tests the element and thermostat, repairs the failed part, and leaves the paperwork."
canonical: "https://lightingelectrical.co.uk/problems/immersion-heater-not-working"
---

# Immersion heater no hot water

> Immersion heater no hot water in Peterborough. Lighting Electrical tests the element and thermostat, repairs the failed part, and leaves the paperwork.

Lighting Electrical traces a cold immersion in Peterborough to the element, the thermostat or the flex, then repairs the failed part.

## Why is the immersion heater not heating water?

The cylinder stays cold or the fuse board trips because the element, the thermostat or the flex has failed. The element is the heater in the tank. The thermostat switches that heater off when the water is hot. The flex is the short cable on the immersion head.
- **The element has failed:** The element sits in the water and heats the tank. A burnt out element leaves the switch on and the water cold. A split element leaks current to the cylinder. The breaker then opens.
- **The thermostat has stuck:** The thermostat tells the element when to stop. If it fails open, the element never comes on and the tank stays cold. If it sticks on, the water keeps heating until a safety device trips.
- **The flex is damaged:** Heat in the airing cupboard hardens the flex on the immersion head. Cracked insulation lets current leak to the tank or the pipes. The breaker or the RCD then opens. An RCD cuts the power when current leaks to earth.
- **The wall switch or isolator is open:** A wall switch or a local isolator feeds the immersion. An isolator is the switch beside the cylinder that cuts its power. A failed switch, or a switch left off, leaves the element with no supply.
- **The immersion breaker has tripped:** The immersion has its own breaker in the fuse board. A breaker opens on too much current or on a leak to earth. It stays open while the element, thermostat or flex is faulty. Other circuits can stay on.

## What can I check safely on a cold cylinder?

You can read the wall switch, the taps and the fuse board with every cover left on. Leave the immersion cap, the fuse board cover and any gas appliance untouched.
- **The immersion switch on the wall:** You look at the switch that feeds the immersion. If it has a light, you see whether that light is on. The switch screws stay in place. A switch that is on, with cold water, means the fault is further along.
- **The hot tap and the cold tap:** You run a hot tap and a cold tap. Cold water from the hot tap, with the cold tap running normally, means the cylinder is not heating. A tap that splutters means you note a possible empty tank and leave the pipes alone.
- **The breaker behind a closed cover:** You find the breaker named for the immersion or the water heater. You read it through the closed cover. If it is down, and the board is cool and quiet, you reset it once. If it opens again, you leave it off.
- **Heat, noise or a burning smell:** A warm switch, a buzz or a smell of burning means you stop. You leave that switch as it is. You keep your hands off the cap on top of the cylinder. That cap covers live terminals.

## When should I book for no hot water from the cylinder?

Book Now if the tank stays cold with the immersion switch on, or if the breaker opens as soon as that switch is turned on.
- **The tank stays cold with the switch on:** The wall switch is on and one reset has held. The hot taps still run cold. The element or the thermostat is not heating the water. That needs a test at the cylinder.
- **The breaker trips as the immersion comes on:** You switch the immersion on and the breaker opens at once. Current is leaking from the element or the flex. Another reset heats that fault. You leave the breaker off.
- **A burning smell or water at the cylinder top:** A burning smell at the switch or the fuse board means the immersion stays off. Water around the thread where the immersion enters the cylinder also needs a test. You leave that thread tight.

## What happens on an immersion heater repair visit?

We switch the immersion off, test the element and the thermostat, then repair the failed part. Other circuits in the home stay on.
- **Isolation at the cylinder:** We find the cylinder, the wall switch and the isolator. We switch off the immersion breaker. We prove the cable is dead before any cover comes off. The rest of the fuse board stays as we found it.
- **Tests on the element and the thermostat:** A continuity test checks that the element and the thermostat still conduct. An insulation test checks that current is not leaking to the cylinder. The two readings name the element, the thermostat or the flex.
- **The repair after you accept it:** We name the failed part before we change it. A thermostat repair leaves the water in the tank. An element repair starts with a drain. We fit the new element and refill. We replace damaged flex when the element and the thermostat both test sound.
- **Power back on and the paperwork:** We switch the immersion back on. We check whether the cylinder starts to heat. Where the circuit was changed, we leave a minor works certificate with our NAPIT registration. We check earthing, bonding and that the supply can feed the immersion before a further price is written. Earthing carries fault current to the fuse board. Bonding links metal pipes to that earth.

## What does immersion heater repair cost?

Immersion heater repair is charged by the hour. That charge covers testing the element, the thermostat and the flex, telling you what failed, and doing the repair once you accept it. The hours change when the cylinder must be drained, when a new element or thermostat is needed, or when the airing cupboard is tight to work in.
- Immersion heater repair: from £70 an hour
- Draining and refilling the cylinder for a new element takes longer than a thermostat repair with the water left in.
- A new element or a new thermostat is charged as well as the hourly labour.
- A cramped airing cupboard or a plant room adds time at the same hourly rate.

## Questions about a cold immersion heater

### Why does the immersion trip the fuse board?

The breaker opens because the element or the flex is leaking current to the cylinder or the pipes. We isolate that circuit and test both parts. We replace the failed part and test the circuit again.

### Do you drain the hot water cylinder?

We drain the cylinder when the element has to come out. A failed thermostat is changed with the water left in the tank. You hear which part failed before a drain cock is opened.

### Do you replace the immersion element?

We replace the element when the tests show it has failed. We replace the thermostat when that is the failed part. We repair the flex when both parts test sound, and the new part is charged with the labour.

### Can a landlord book immersion heater repair?

Yes. We repair immersions in rented cylinders for landlords in Peterborough and the other towns we cover. The work puts the electric heater in that cylinder back into service. You keep the electrical paperwork when the work is finished.

### What paperwork is left after the repair?

A minor works certificate records the tests when we change the element, the thermostat or the flex. It carries our NAPIT registration. If the circuit is only isolated and nothing is changed, we still write down the readings and the failed part.

## Related problems
- [Immersion heater tripping the electrics](https://lightingelectrical.co.uk/problems/immersion-heater-tripping): The immersion circuit trips because the element, thermostat or flex leaks current to the cylinder.
- [Aluminium wiring in the house](https://lightingelectrical.co.uk/problems/aluminium-wiring): Aluminium cable overheats at loose joints. We test it, write the electrical installation condition report, and price any copper replacement separately.
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Bathroom fan stopped working](https://lightingelectrical.co.uk/problems/extractor-fan-not-working): A stopped extractor fan means a seized motor, an open switch, or a fault on the circuit that feeds it.
- [Brown marks on a socket or plug](https://lightingelectrical.co.uk/problems/scorch-marks-on-socket): Brown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- [Burning plastic smell from electrics](https://lightingelectrical.co.uk/problems/burning-plastic-smell-electrical): A burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.

## Sources
- [Energy Saving Trust: Heating Your Home](https://energysavingtrust.org.uk/advice/heating-your-home/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)

Updated 2026-11-16.

[Immersion heater repair](https://lightingelectrical.co.uk/services/immersion-heater-repair)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)