An immersion heater that trips the electrics has a fault on the cylinder circuit. Lighting Electrical in Peterborough tests the element and the thermostat. We then repair the failed part.

## Why does an immersion heater trip the electrics?

The immersion trips because current leaks from the element, the thermostat or the flex onto the cylinder. An RCD, the safety switch that opens when current leaks to earth, then cuts that circuit.
- **A failed immersion element:** The element is the heated part inside the cylinder. When its insulation fails, current reaches the tank metal. The RCD opens as soon as the immersion is switched on, or once the element warms.
- **A failed immersion thermostat:** The thermostat switches the element off at the set temperature. A cracked thermostat can pass current to the cylinder boss. The RCD opens and the tank stays cold.
- **Damaged flex at the cylinder head:** The flex is the short cable from the isolator to the immersion head. Heat at a loose gland cracks the sheath. Bare copper touches the cap or the pipework and the RCD opens.
- **Water on the immersion head:** A weeping gland wets the terminals on the cap. Wet terminals leak current to the cylinder. The RCD opens and will not hold while that head stays wet.

## What can you check safely when an immersion trips?

You can read the fuse board and the immersion switch with every cover left on. You do not open the cylinder head. You do not touch the wiring.
- **Which switch has opened:** Look through the closed fuse board cover. A dropped immersion breaker or RCD, with the other switches still up, means the leak is on the cylinder circuit. Leave the cover screws in place.
- **The immersion switch on the wall:** Use the immersion switch you already use for the cylinder. Switch it off. If the RCD then stays up, the leak is on the immersion side of that switch.
- **One reset while the board is cool:** Reset the RCD once when the board is cool, silent and has no burning smell, with the immersion switch off. If it opens again at once, leave it off.
- **Water around the cylinder:** Look at the airing cupboard floor and the outside of the cylinder. A puddle or a wet cap means water has reached the head. Do not wipe inside the cap. Do not loosen any nut.

## When should you book for a tripping immersion?

Book Now when the RCD will not hold, the cupboard smells of burning, or water is sitting on the immersion head.
- **The RCD drops again:** The immersion switch is off and the RCD still opens, or it opens the moment the immersion goes on. Another reset heats the device. Leave that circuit off.
- **A burning smell or a hot board:** A hot fuse board, a buzz or a smell of burning means a joint is failing. Use the switch on the front to leave the immersion off. Keep the cover on.
- **Water on the head and cold taps:** A wet cylinder cap together with a trip means the water and the leak are in the same place. Hot taps stay cold while that circuit is off. Book Now so the head can be tested with the power off.

## What happens on an immersion heater repair visit?

We isolate the immersion, test the element and the thermostat, and repair the part that has failed. Other circuits stay on while that work is done.
- **Finding the cylinder and isolating it:** We find the cylinder, the wall switch and the isolator. An isolator cuts the immersion on its own. We switch that circuit off and prove it is dead before any cover comes off.
- **Testing the element and the thermostat:** We test insulation and continuity on the element, the thermostat and the flex. The readings name the part that is leaking to the cylinder. A part that tests sound stays fitted.
- **The repair after you accept it:** We tell you whether the element, the thermostat or the flex has failed. The repair starts after you accept it. An element change means the cylinder is drained first. A thermostat change leaves the water in the tank.
- **Power restored and the certificate:** We refit the covers and switch the immersion on for a test. Where we alter the circuit, a minor works certificate records the tests under our NAPIT registration. We leave the immersion off if that test fails, and every other circuit stays on.

## What does immersion heater repair cost?

Immersion heater repair is charged by the hour. The price covers testing the element, the thermostat and the cylinder wiring, and the repair that follows once you accept it. Draining the cylinder, a new part, or a minor works certificate changes the price.
- Immersion heater repair: from £70 an hour
- Draining the cylinder to change the element takes longer than a thermostat repair that leaves the water in the tank.
- A new immersion element or thermostat is added to the hourly labour.
- Tight access in an airing cupboard or a plant room adds time at the same hourly rate.

## Questions about an immersion heater tripping

### Why does my immersion heater trip the RCD?

Current is leaking from the element, the thermostat or the flex to the cylinder, so the RCD opens. We isolate that circuit and test each of those parts. We replace the one that is leaking, and the other circuits stay on.

### Should I reset the immersion again?

One reset is reasonable with the immersion switch off, and only when the board is cool, silent and has no burning smell. If the RCD opens again at once, stop there. We test the immersion circuit rather than asking for another reset.

### Do you drain my hot water cylinder?

We drain the cylinder when the element has to come out. A thermostat repair leaves the water in the tank. We test first and tell you which of the two jobs it is before any water is run off.

### Will my lights and sockets stay on?

Yes. We isolate the immersion and leave every other breaker as we found it. The immersion goes back on after the repair when the tests allow it. A circuit that fails the test stays switched off.

### Do you repair immersions for landlords?

Yes. We repair immersion heaters on rented cylinders for landlords. The work is the failed element, thermostat or flex, so the cylinder can heat again. We leave the relevant electrical paperwork when the work is complete.

## Related problems
- [Immersion heater no hot water](https://lightingelectrical.co.uk/problems/immersion-heater-not-working): The cylinder stays cold because the immersion element, thermostat or flex has failed, and repair starts with a test.
- [Aluminium wiring in the house](https://lightingelectrical.co.uk/problems/aluminium-wiring): Aluminium cable overheats at loose joints. We test it, write the electrical installation condition report, and price any copper replacement separately.
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Bathroom fan stopped working](https://lightingelectrical.co.uk/problems/extractor-fan-not-working): A stopped extractor fan means a seized motor, an open switch, or a fault on the circuit that feeds it.
- [Brown marks on a socket or plug](https://lightingelectrical.co.uk/problems/scorch-marks-on-socket): Brown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- [Burning plastic smell from electrics](https://lightingelectrical.co.uk/problems/burning-plastic-smell-electrical): A burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [Energy Saving Trust: Heating Your Home](https://energysavingtrust.org.uk/advice/heating-your-home/)

Updated 2026-11-16.

[Immersion heater repair](https://lightingelectrical.co.uk/services/immersion-heater-repair)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)