# Kitchen under cabinet lights not working

> Kitchen under cabinet lights not working in Peterborough: why they fail. · 4.7 Star from 63 reviews · Prices from £60 · Call 07414 545781

When kitchen under cabinet lights go dark, the fault sits in the small power box behind them or in the switch and breaker ahead of it. Lighting Electrical in Peterborough tests each stage until the failed part shows.

## Why have my kitchen under cabinet lights stopped working?

Most under cabinet lights run on low voltage, so a small box called a driver or transformer steps mains power down for them. Which lights went out shows where the fault sits.
- **The driver has failed:** The driver is the box that lowers mains voltage for the strip or spotlights. When it fails, every light wired to it goes dark at once while the rest of the kitchen lighting keeps working.
- **Power no longer reaches the driver:** A dropped breaker, a switched off isolator or a worn wall switch stops power getting to the driver. The whole run goes out together, which looks the same as a failed driver until it is tested.
- **One lamp or its connector has failed:** When one light is dead and its neighbours work, the fault is that lamp or its connector. The driver is sound, because it still feeds the others.
- **The lamps do not suit the dimmer:** A lamp not made for dimming flickers or drops out on a dimmer switch. A replacement lamp that does not match the fitting and the driver rating cuts out in the same way.
- **A connection has worked loose or corroded:** A poor joint between the driver and a light leaves that light dead or cutting out. A loose joint also runs warm inside the cupboard, so it needs attention soon.

## What can I check safely before calling an electrician?

Every check below keeps covers on and the driver closed. Switch the lights off and stop if you smell burning or feel heat.
- **Count the dead lights:** Note whether one light or the whole run is out. A whole run points at the driver or what feeds it, and one light points at its own lamp.
- **Try the wall switch and dimmer:** Flick the switch off and on, then turn any dimmer fully up. A switch that feels loose or gritty can be the part that stopped the power.
- **Look at the kitchen lighting breaker:** Check whether the breaker for the kitchen lights has dropped to off at the consumer unit. Push it up once, and if it drops again leave it off.
- **Look for heat marks:** Look at the fittings and the cupboard around the driver for scorching or brown marks, without opening anything. If you see any, switch the lights off at the consumer unit and leave them off.

## When should I book an electrician for dead under cabinet lights?

Book Now when the whole run stays dead after the switch and breaker check, or when anything shows heat. A dark worktop is a nuisance, while heat in a cupboard needs attention the same day.
- **The switch works and the breaker is up:** With both fine and no light on, the fault sits in the driver or the wiring feeding it. Both need testing with meters.
- **Scorching, heat or a burning smell:** Switch the lights off at the consumer unit and keep them off. A driver or fitting that has overheated is replaced, not reset.
- **Flicker or dropouts:** Lights that flicker or cut out point to a lamp and dimmer mismatch or a loose joint. Testing tells you which.
- **The lights failed after other kitchen work:** A new appliance, unit or fitting can disturb a cable or connector behind it. We check what that work touched.

## What happens when the electrician visits?

We follow the power from the wall switch to the last light, then switch the lights on so you see them work.
- **Questions first:** We ask which lights are out, when it began and what changed beforehand. Then we look at the switch, any dimmer and the breaker.
- **Testing along the circuit:** We switch the circuit off at the board, then measure at the switch, going into the driver and coming out of it. The readings name the failed part before anything is replaced.
- **Replacing the failed part:** A failed driver is swapped for one chosen to suit the lights' voltage and combined wattage. Loose connectors are remade and damaged fittings are replaced.
- **Final test and paperwork:** We test the circuit and switch the lights on from the wall. A minor works certificate is completed when the repair needs one.

## What does fixing under cabinet lights cost?

The price covers fitting the lights you have chosen, connecting them to the existing lighting circuit and a switch that works them. Tracing a fault first is charged by the hour, and the number of fittings, new cable and a replacement switch or dimmer change the total.
- Downlight installation (per fitting): from £65
- The price is set per fitting, so each extra light fitted adds to it.
- A new length of cable to reach a light adds time and materials.
- A minor works certificate is added when the job needs one.

## Lighting installation near you
- [Lighting installation in Colchester](https://lightingelectrical.co.uk/electrician-colchester/lighting-installation)
- [Lighting installation in Dedham](https://lightingelectrical.co.uk/electrician-dedham/lighting-installation)

## Under cabinet lighting questions

### Can I fit any replacement LED in my under cabinet lights?

No. The marking on the fitting gives the type and wattage it accepts, and a lamp outside it can cut out or run hot. Send us the marking and we match a lamp to it.

### Will you replace parts before you know the cause?

No. We test first and name the failed part, whether driver, switch, connector or lamp. Replacement starts once you accept the work.

### Can you fit new under cabinet lights as well as repair old ones?

Yes. We fit the lights you have chosen and connect them to the existing lighting circuit where that circuit is sound. The matching switch or dimmer is replaced in the same visit when it is on the quote.

### Do I get a certificate after the repair?

A minor works certificate comes with a repair that needs one. We are NAPIT registered, and that registration covers the certificate.

## Related problems
- [Dimmer switch lights flicker](https://lightingelectrical.co.uk/problems/dimmer-lights-flickering): Flicker on a dimmer comes from lamps that do not suit the dimmer, or from a loose joint on the lighting circuit.
- [Dimmer switch not working](https://lightingelectrical.co.uk/problems/dimmer-switch-not-working): A dimmer stops working when its module fails, the lamps cannot dim, or the lighting circuit opens.
- [Lights flickering after a new fitting](https://lightingelectrical.co.uk/problems/lights-flickering-after-new-fitting): A new fitting flickers when the lamp, the dimmer or a loose joint does not suit the lighting circuit.
- [Pull cord light switch not working](https://lightingelectrical.co.uk/problems/pull-cord-not-working): A dead pull cord is a worn ceiling switch, a failed lamp, or an open lighting circuit.
- [Why is my ceiling light buzzing](https://lightingelectrical.co.uk/problems/light-fitting-buzzing): A buzzing ceiling light is a loose joint, a failing lamp or a dimmer that does not suit the lamp.
- [Why is my dimmer switch humming?](https://lightingelectrical.co.uk/problems/dimmer-switch-buzzing): Hum comes from lamps that do not suit the dimmer, or from a loose joint in the switch.

## Sources
- [Electrical Safety First: downlights](https://www.electricalsafetyfirst.org.uk/guidance/safety-around-the-home/downlights/)
- [Electrical Safety First: safe installation of retrofit LED lamps (Best Practice Guide 9)](https://www.electricalsafetyfirst.org.uk/media/pqkn2dgz/best-practice-guide-9.pdf)

Updated 2026-11-20.

[Lighting installation](https://lightingelectrical.co.uk/services/lighting-installation)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)