title: "Why are my LED lights flickering? | 4.7 Star · NAPIT · From £60"
description: "LED lights flickering in Peterborough: Lighting Electrical tests the lamp, the dimmer and the lighting circuit, then names the part that has failed."
canonical: "https://lightingelectrical.co.uk/problems/led-lights-flickering"
---

# Why are my LED lights flickering?

> LED lights flickering in Peterborough: Lighting Electrical tests the lamp, the dimmer and the lighting circuit, then names the part that has failed.

LED lights flicker when a lamp, a dimmer or a joint on the lighting circuit is failing. Lighting Electrical in Peterborough tests that circuit and names the part that has failed.

## Why do LED lights flicker?

LED lights flicker when the lamp, the dimmer or a connection on the lighting circuit is failing. The flash comes from the lamp, the dimmer or the cable.
- **An old dimmer with LED lamps:** A dimmer reduces power to every lamp on one switch. Older dimmers expect a filament bulb. An LED lamp on that dimmer flashes when the knob is turned down. The lamps stay steady at full brightness when the dimmer is the cause.
- **A loose joint at the switch or rose:** A ceiling rose joins the pendant cable to the lighting circuit. A loose screw there opens and closes the connection. The LED lamp flashes on each break. A loose terminal in the light switch does the same.
- **A failing driver inside the lamp:** The driver is the part in an LED lamp that turns mains power into the lower voltage the lamp needs. A dying driver flashes the lamp on a plain switch. A spare lamp that stays steady in the same holder shows the first lamp has failed.
- **A transformer left from halogen downlights:** A transformer lowers mains voltage for older downlights. It expects the heavier load of a halogen lamp. LED lamps draw less current, so the output wanders and the lamps flash. The transformer is the failed part.
- **A loose neutral on the lighting circuit:** The neutral is the return wire that completes the circuit back at the fuse board. A loose neutral lets the voltage on that circuit rise and fall. LED lamps on the circuit flash together. Lamps on another circuit stay steady.

## What can I check safely at home?

You can see which lamps flash, try one spare lamp, and look at the dimmer and the fuse board. Every cover stays on.
- **Which lamps flash:** Switch each room on in turn. One lamp flashing points to that lamp or its holder. Every lamp on one switch flashing points to the dimmer or a joint. Lamps flashing in several rooms point to the lighting cable or the fuse board.
- **A spare lamp in the same holder:** Switch the light off at the wall. Fit a spare LED lamp you already know works. A steady spare means the old lamp failed. A spare that also flashes means the fault is in the dimmer, the holder or the cable.
- **The dimmer at full brightness:** Turn the dimmer all the way up. Flashing only when it is turned down points to a dimmer that does not suit LED lamps. Flashing at full brightness points to the lamp, a joint or the cable. Leave the dimmer screws in place.
- **The lighting breaker through the cover:** Read the fuse board through the closed cover. The lighting breaker sits up while the lamps flash. A breaker that has dropped out is a trip, which is a different fault. Leave the cover screws untouched.

## When should I book for flickering LED lights?

Book Now when a spare lamp still flashes, or when a switch, dimmer or fitting is hot, buzzing or smelling of burning.
- **A spare lamp still flashes:** The lamp is not the cause. The fault sits in the dimmer, a joint or the lighting cable. Another lamp in that holder will flash as well. Book Now so the circuit can be tested.
- **Heat, a buzz or a burning smell:** Heat or a buzz at a switch, dimmer or ceiling rose means a joint is arcing. Arcing is a spark jumping across a loose connection. The spark chars the cable. Leave that lighting switch off and Book Now.
- **Lamps flash in more than one room:** Several rooms flashing together point to the lighting cable or a loose neutral. One lamp is not the cause. The circuit needs a test before that joint overheats.

## What happens on a visit for flickering lights?

We test the lighting circuit and name the failed lamp, dimmer, driver or joint before any part is changed.
- **Which rooms flash and when it began:** We ask which rooms flash and whether a dimmer is fitted. We ask if the flash began after new lamps went in. We read the lighting breaker with you through the closed fuse board cover.
- **Meter readings with the circuit off:** We switch the lighting circuit off at its breaker. Meters then read the cable with no power on it. The readings separate a lamp, a driver, a dimmer, a loose joint and a loose neutral. We name that part before we open a fitting.
- **Earthing, bonding and the supply:** Earthing is the path fault current takes back to the fuse board. Bonding joins metal pipes to that earth. We check both, and we check the supply can carry the load, before we write any further price.
- **The repair and the certificate:** Work on the named part starts when you accept the repair. We test the lighting circuit again after the work. A minor works certificate follows when the repair alters the circuit, under our NAPIT registration. The breaker stays off if the circuit cannot go back on.

## What does flickering LED fault finding cost?

Electrical Fault Finding & Repair is charged by the hour. That price covers tests on the flickering lamps, the diagnosis we give you, and the start of the repair once you accept it. Tracing a fault along the lighting cable takes longer than testing one lamp. A dimmer, a driver, a minor works certificate or Lighting Installation changes the price when the finding needs that work.
- Fault finding & repair: from £75 an hour
- A test on one lamp takes less time than tracing a loose neutral between rooms.
- A Varilight dimmer or an MK Electric switch is fitted only when the tests show that part has failed.
- Fuse board replacement carries its own price when the lighting breaker or the board has failed.

## Questions about flickering LED lights

### Will a new bulb stop LED lights flickering?

A new bulb stops the flicker only when that bulb has failed. We test the holder against the dimmer and the cable before we fit anything. The old bulb stays if the dimmer or a joint is the cause.

### Can a dimmer make my LED lights flicker?

Yes. A dimmer built for filament bulbs cuts each mains wave in a way LED lamps do not follow. The lamps flash when the dimmer is turned down. We fit a Varilight dimmer for those lamps when the test shows the old dimmer is the cause.

### Should I leave flickering LED lights switched on?

A cool lamp that flashes can be switched off at the wall. Heat, a buzz or a smell of burning means that switch stays off. Book Now so the joint can be tested before the cable is charred.

### Will you fix the flicker on the same visit?

We name the failed lamp, dimmer, driver or joint before any part is changed. The repair of that part goes ahead on the visit when you accept it. Fuse board replacement waits for its own price.

### Do I get a certificate after the lighting repair?

You get a minor works certificate when the repair changes the lighting circuit. The certificate lists the tests and our NAPIT registration. A lamp swap with no change to the wiring has no certificate.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [NICEIC: Householder Guidance](https://niceic.com/householders/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question