# Light bulbs keep blowing

> Light bulbs keep blowing? Lighting Electrical in Peterborough tests the fitting, dimmer and circuit to name the cause, then repairs it by the hour.

Bulbs that keep dying usually mean the lamp does not suit its fitting, or heat or a poor contact is wearing it out. Lighting Electrical tests the fitting and circuit in Peterborough until the cause has a name.

## Why do light bulbs keep blowing?

Repeat failures come from heat, a poor electrical contact or a lamp that does not suit the fitting, and where they happen shows which.
- **A lamp stronger than the fitting is rated for:** The rating plate on a fitting states the highest lamp power it can take. A stronger lamp makes more heat than the fitting can lose, so the bulb dies early and the holder bakes.
- **The wrong kind of lamp in a downlight:** A downlight, the recessed light set into a ceiling, is built for one lamp shape and one beam type. A cool beam halogen with a glass reflector throws its heat back into a fitting made for another lamp.
- **An LED lamp that cannot be dimmed, on a dimmer:** A dimmer is the wall control that lowers brightness. An LED lamp built only for full brightness can flicker, hum and fail early on one, and an old dimmer can upset even a lamp made for dimming.
- **Heat trapped above the ceiling:** Insulation or boarding packed round a downlight keeps its heat in. Fittings made to sit in insulation cope with it, while others cook the lamp and the fitting together.
- **A damaged lampholder:** The lampholder is the socket the bulb pushes into. Once heat has marked it or its metal contacts have worn, the bulb sits on a poor contact, so each new one gets hot at that spot and fails the same way.
- **A loose connection on the lighting circuit:** A loose joint at a switch, ceiling rose or junction box makes the current arc and drop in bursts. Bulbs on that circuit flicker and fail young, often in more than one fitting.

## What can I look at safely myself?

With the light switched off at the wall and the bulb cooled, you can read, look and make notes from the floor without any tools.
- **Read the markings:** Compare the power and lamp type printed on the fitting with the bulb in it and with its packaging. Fit only a lamp that matches both.
- **Check the packaging for dimming:** If the light runs from a dimmer, look on the bulb packaging for a statement that the lamp can be dimmed. Leave the dimmer plate on the wall as it is.
- **Look at the holder and the ceiling:** From below, look for brown marks, a melted edge or a burnt smell around the fitting. If you see any, leave the light switched off and do not put in another bulb.
- **Note the pattern:** Write down whether one fitting, one room or every room is affected, how long each bulb lasted and when it began. Photos of the fitting and any dimmer help the electrician.

## When is it time to call an electrician?

Call when bulbs that match the markings still fail, and without waiting when any fitting shows signs of heat.
- **Heat marks or a burning smell:** Brown marks, a melted holder or a smell of burning mean heat has already done damage. Keep that light off and book without waiting.
- **Matching bulbs still fail:** A bulb of the right type and power that still dies young points to the fitting or the circuit behind it, and only testing can say which.
- **Failures began after new work:** Bulbs that started dying once a dimmer, new fittings or new downlights went in suggest a mismatch that testing can pin to one place.
- **Downlights sit under insulation:** Recessed fittings buried in loft insulation need checking for their rating, however long the bulbs are lasting.

## What does the electrician do on the visit?

The visit starts with what has been failing, moves to testing, and ends with a named cause and a clear next step.
- **We hear what has been failing:** We walk the property with you, note which fittings fail and since when, and look at the fitting, any dimmer and the fuse board.
- **We test until the cause is clear:** We isolate the circuit, measure at the board and along the run, and name the failed holder, accessory, cable or device before we replace anything.
- **We repair and leave the paper:** Once you accept the hourly repair, we fix that finding and restore the circuit. A minor works certificate follows when the repair needs one.

## How is fault finding for blowing bulbs priced?

Fault finding is charged by the hour. That time pays for testing the fitting, any dimmer and the circuit, a spoken diagnosis, and the start of the repair once you accept it. A fitting that shows its fault at once takes less time than one that fails only now and then.
- Fault finding & repair: from £75 an hour
- A lampholder, fitting or dimmer is added only when the testing shows that part has failed.
- A new lighting circuit or a fresh set of fittings is quoted in writing as its own job.
- A minor works certificate is added when the repair alters the circuit.

## Electrical fault finding near you
- [Electrical fault finding in Colchester](https://lightingelectrical.co.uk/electrician-colchester/electrical-fault-finding)
- [Electrical fault finding in Heybridge](https://lightingelectrical.co.uk/electrician-heybridge/electrical-fault-finding)

## Questions about bulbs that keep blowing

### Will you change parts before you know the cause?

No. We test first and name the failed joint, accessory, cable or device. Replacement starts once you accept the repair.

### Can you find a fault that only shows now and then?

Often yes. Flickers and warm fittings leave traces at the board or along the circuit. If the fault will not show on the day, we tell you what we found and what still needs watching.

### Do I get a certificate after the repair?

A minor works certificate comes with the repair when the work needs one, and it is charged on top of the hourly time. An EICR, which is a full electrical safety report on the wiring, is a separate inspection if you want one as well.

### What will it cost to find out why my bulbs keep dying?

We charge by the hour for the testing and diagnosis, with parts added only if one has failed. Bigger work, such as a new circuit, is priced in writing before it starts.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Cooker switch not working](https://lightingelectrical.co.uk/problems/cooker-switch-not-working): A dead cooker usually means a tripped breaker, a failed cooker switch, a loose connection behind it or a fault inside the cooker itself.
- [Cooker tripping the electrics](https://lightingelectrical.co.uk/problems/cooker-tripping-electrics): A cooker trips the electrics when an element leaks current to earth, a connection overheats or the circuit carries more than it can bear.

## Sources
- [Electrical Safety First: downlights](https://www.electricalsafetyfirst.org.uk/guidance/safety-around-the-home/downlights/)
- [Electrical Safety First: safe installation of retrofit LED lamps (Best Practice Guide 9)](https://www.electricalsafetyfirst.org.uk/media/pqkn2dgz/best-practice-guide-9.pdf)

Updated 2026-11-20.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)