# Lighting circuit keeps tripping

> Lighting circuit tripping in Peterborough means Lighting Electrical tests the breaker and the fittings and names the failed lamp, switch or cable.

A lighting circuit that keeps tripping has a leak or an overload on the lights. Lighting Electrical in Peterborough tests that circuit and names the failed fitting, switch or cable.

## Why does a lighting circuit keep tripping?

The lights trip because current on that circuit is too high or is leaking to earth. Sockets stay on when they sit on another breaker.
- **Too many lamps on one lighting breaker:** A lighting circuit is the cable that leaves the fuse board and feeds the light points. Extra pendants or an added run of lamps raise the current. The breaker opens when that current passes its rating. The lights on that breaker go out.
- **A failed lamp, driver or dimmer:** An LED lamp uses a driver, a small power supply in the lamp or the fitting. A failed driver leaks current to earth. A dimmer that fights the lamps leaks as well. The breaker or the RCD opens when that light is switched on.
- **Water in a lantern or a bathroom light:** Rain inside a wall lantern, or steam in a bathroom light, joins the live parts to earth. Earth is the safety path that should carry fault current only. The RCD sees the leak and opens. Indoor lights on that RCD go dark with the wet fitting.
- **A loose joint in a rose or a switch:** A ceiling rose is the joint above a pendant. Heat loosens a screw there, or in the switch. The loose joint arcs. Arcing is a spark jumping a poor connection. The spark chars the insulation. The breaker opens, or the RCD opens when the char reaches earth.
- **One RCD feeding all the lights:** An RCD is a switch that opens when current leaks to earth. On many fuse boards one RCD feeds every lighting circuit. A leak in a single fitting opens that RCD. Every room on it goes dark together. Sockets on the other RCD stay on.

## What can I check while the covers stay on?

You can read the breakers through the closed fuse board cover. You can switch the lights off and see which rooms go dark.
- **The lighting switch behind the cover:** Look at the fuse board with the cover shut. A lighting breaker sitting down is the circuit that opened. An RCD sitting down has opened every circuit it feeds. Reset it once only when the board is cool, quiet and free of any burning smell.
- **All lights off, then one reset:** Switch off every light, including outside lanterns and every dimmer. Push the lighting switch up once. If it holds, turn the rooms on one at a time. The room that drops the switch holds the failed fitting. If it drops at once, leave it off.
- **One room dark or the whole circuit:** A single dark room points to a fitting or a switch in that room. Every light on the breaker going dark points to the cable, the breaker or the RCD. Sockets that still work are on their own circuit. Remember which rooms went dark.
- **Rain, the bathroom or a dimmer:** If the trip follows rain, leave the outside lanterns off. If it follows the bathroom light or the fan, leave that switch off. If it follows one dimmer, leave that dimmer off. Wipe the face of a wet switch only. Leave every screw in place.

## When should I book for tripping lights?

Book Now if the lighting switch will not stay up, or if a fitting, a dimmer or the fuse board is hot, buzzing or smelling of burning.
- **The switch will not stay up:** The lights are switched off and the breaker still opens. The fault remains in a fitting, a joint or the cable. Another reset warms the terminals. Leave the lighting breaker off and Book Now.
- **Heat, noise or a burning smell:** A warm rose, a buzzing dimmer or brown marks on a switch mean the joint is arcing. Switch that circuit off with the breaker handle. Keep your hands off the rose and the switch screws. Book Now while that breaker stays off.
- **One fitting always starts the trip:** The circuit holds until one room, one dimmer or the outside lantern comes on. That fitting is leaking or pulling too much current. Leave it switched off. Book Now so we can test the circuit dead.

## What happens on a visit for tripping lights?

We switch the lighting circuit off, test it dead, and name the failed part before we change a fitting, a switch or a cable.
- **Which lights fail and which switch opened:** We ask which rooms go dark. We ask whether rain, a dimmer or one lantern starts the trip. We look at the lighting breaker and the RCD with you. No cover comes off until a tester shows that circuit is dead.
- **Dead tests on the lighting cable:** We switch the lighting circuit off at its breaker. We measure for a short between the conductors. We measure for a broken conductor. We measure for leakage to earth. The readings separate a lamp, a rose, a switch, a cable and the device in the board.
- **The failed part before any replacement:** We name the failed lamp, rose, switch, cable or device. We open only that part. A fitting that tests sound stays shut. We measure the earth path and the bonds to metal pipes before we write any further price.
- **The repair and the certificate:** The repair of the named part goes ahead after you say yes. We test the lighting circuit again afterwards. A minor works certificate records a change to the circuit under our NAPIT registration. We leave the breaker off when the circuit must stay dead.

## What does a lighting fault visit cost?

Fault finding on a lighting circuit is charged by the hour. The hour pays for the tests, the diagnosis we talk through with you, and the first part of the repair after you say yes. A leak through several ceiling roses takes longer than a lamp that trips the moment it is switched on. A part, a minor works certificate or a new fuse board changes the price. Emergency electrician work is priced on its own.
- Fault finding & repair: from £75 an hour
- Time rises when the leak runs through several roses rather than one lamp that trips as soon as it is switched on.
- We fit a switch, a dimmer or a breaker from MK Electric, Varilight, Hager, Wylex, Contactum or BG Electrical only after that part fails its test.
- A new fuse board is priced as its own job when the breaker for the lights or the board has failed.

## Questions about lights that keep tripping

### Will the rest of the house stay on?

Yes. We switch off the lighting circuit that is tripping and leave healthy circuits on. Sockets stay live while the lights are tested. The lighting breaker goes back on after the repair. It stays off when the circuit must remain dead.

### Will a new fuse board stop the tripping?

A new fuse board stops the trip only when the lighting breaker or the board has failed its test. A wet lantern, a failed driver or a loose rose still trips the lights on a new board. Fuse board replacement has its own price after the test.

### Do you swap lamps and switches before the test?

No. We name the failed lamp, rose, switch, cable or device before anything is changed. Work on that part starts after you say yes. A fitting that passes the test stays where it is.

### Do I get a certificate after the lighting repair?

A minor works certificate follows when we alter the circuit. It records the test results for that job and our NAPIT registration. If we change nothing and leave the breaker off, we record the readings and the failed part. An EICR is a separate inspection of the whole installation.

### Why does one outside light knock out the indoor lights?

A lantern that leaks to earth opens the RCD that feeds the indoor lights as well. We test the lantern apart from the indoor lights. We name the lantern when the leak is in it. We put the indoor lights back when their wiring tests sound and the lantern stays off.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [NICEIC: Householder Guidance](https://niceic.com/householders/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)