# Lightning hit house electrics

> House electrics after lightning in Peterborough suffer a voltage spike through the fuse board. We test damaged circuits and switch off any that are unsafe.

Lightning that hits house electrics sends a sudden high voltage into the fuse board and into equipment left plugged in. Lighting Electrical in Peterborough tests each damaged circuit and leaves an unsafe one switched off.

## Why does lightning damage house electrics?

Lightning damages house electrics because a very high voltage enters on the supply cable and burns connections in the fuse board and in equipment left plugged in.
- **A spike on the supply cable:** The supply cable brings power from the street into the fuse board. A strike on the lines or on nearby ground drives a short, very high voltage down that cable. The spike reaches the main switch before a breaker opens.
- **Breakers and safety switches:** A breaker is the switch that opens when a circuit draws too much current. An RCD, a residual current device, opens when current leaks to earth. The spike can weld the contacts or crack the device, so the switch will not close or will not open on the next fault.
- **A surge protection device:** A surge protection device in the fuse board clamps a short voltage spike. A close strike can destroy that device and still push energy into the circuits. The board needs a test before normal use returns.
- **Burnt joints and scorched cable:** Voltage that jumps a loose terminal chars the copper and the plastic around it. Brown marks at a socket, a switch or the fuse board show a joint that has burnt. That joint stays a fire risk after the storm has passed.
- **Solar kit, alarms and chargers:** An inverter turns solar power into mains power, and a battery unit stores it. The same spike stops an inverter, a fire alarm panel or an EV charge point while some house lights come back on. Those circuits need their own test.

## What can you check safely after a lightning strike?

You can look, smell and unplug. The fuse board cover stays on, and no socket, appliance or cable is opened.
- **Switches seen through the cover:** Stand back and read the switches on the fuse board. A switch sitting down has opened. If you smell burning or see soot, leave every switch where it is. With no burning smell and a casing no warmer than the wall, raise the main switch once.
- **Which rooms still have power:** Switch on a ceiling light in two rooms. Note a blank oven clock, a silent alarm panel or a charge point with a warning lamp. Some rooms on and some rooms off show which circuits opened. Every fitting stays screwed shut.
- **Plugs taken out of sockets:** Pull televisions, chargers and small appliances out by the plug. Leave them out. The appliance case stays shut, and a wet or scorched plug is left alone.
- **Marks on fittings and outdoor cable:** Look at socket faces, the meter cupboard door and any outside socket for brown marks or cracked plastic. Stay well clear of a fallen cable or a hanging fitting. The cable and the fitting stay untouched.

## When should you book after lightning hits the electrics?

Book Now when the power stays off, a switch will not stay up, or you smell burning at the fuse board or a fitting.
- **Burning smell or scorch marks:** A burning smell, soot or brown marks at the fuse board, a socket or a switch mean a joint is damaged. That circuit stays off. Book Now before anyone uses the fitting again.
- **A switch that drops straight away:** You raised a switch once and it opened at once. Another attempt heats the damaged part. Leave the switch down. Book Now so the circuit is tested while it is dead.
- **Several appliances dead after the storm:** Lights can be back while a boiler, an alarm panel, a television and a charger stay dead. The fixed wiring needs a test before those plugs go back in. Book Now for that test.
- **Inverter, battery or charge point:** A blank inverter, a battery unit that will not start, or an EV charge point with a warning light shows surge damage. Switch that equipment off at its isolator, the switch that cuts power to one item, if you can do that with the cover still on. Book Now for a test of that circuit.

## What happens on a visit after lightning damage?

We isolate the circuits a voltage spike has damaged, take test readings, and tell you the failed part before a fitting or a breaker is replaced.
- **Which equipment died:** We ask which rooms, appliances and outdoor equipment went off, and when. We stand with you and read every switch through the closed cover. Damaged circuits go off. Circuits that still read healthy stay on.
- **Dead tests on the damaged circuits:** Each damaged circuit is isolated, then tested while it is dead. The test shows whether the copper is broken, shorted or leaking to earth. The readings separate a burnt joint, a failed breaker and a length of cable.
- **Earthing, bonding and spare capacity:** Earthing is the path that carries fault current so a breaker can open. Bonding links metal pipes to that earth. We check both. We also check that the incoming supply has spare capacity for the load. Then we write any further price.
- **Repair or a written price for the larger job:** A failed breaker, socket or short length of cable is replaced after you accept it. The circuit is tested once the new part is in. A fuse board, inverter or charge point that needs a larger job stays off, and that price is written before the job starts. Where a circuit is altered, the minor works certificate lists the tests and our NAPIT registration.

## What does a lightning damage visit cost?

The price covers our attendance, the tests on circuits the spike passed through, and switching off anything unsafe to leave on. A single scorched socket takes less time than a damaged fuse board with several dead circuits. A part we fit, a minor works certificate, or a separate fuse board, inverter or charge point job changes the price.
- Emergency electrician (out of hours): from £90 an hour
- A breaker, socket or cable is fitted when the readings show it has failed.
- Fuse board replacement, inverter work and charge point work each have their own written price.
- An emergency electrician visit is charged apart from later fault finding on the same damage.

## Questions about lightning damage to electrics

### Should I reset the fuse board after a lightning strike?

Raise the main switch once when the casing matches the wall temperature, the board is silent, and there is no burning smell. If the switch opens again, leave it off. We test that circuit dead instead of resetting it again.

### Can the rest of the house stay on?

Yes. Circuits that test healthy stay on. We switch off the damaged circuit only. That circuit stays off when the readings show it is unsafe to put back on.

### Will you replace the fuse board on the same visit?

A fuse board is replaced only when the tests show it has failed and you have accepted a separate written price. A burnt socket or a failed breaker can be put right while the board stays. Otherwise the damaged circuit stays off and the board price is written on its own.

### What paperwork do I get after the repair?

Where we alter a circuit, the minor works certificate lists the test results and our NAPIT registration. Where we only isolate a circuit, we write down the readings and the failed part. An EICR, an Electrical Installation Condition Report, is a separate inspection of the whole installation.

### What if my solar kit or EV charger is dead?

We test the circuit that feeds the inverter, the battery unit or the charge point. The equipment stays off when the readings show surge damage. A replacement is priced on its own, and charge points we fit include Ohme, myenergi, Hypervolt and Andersen.

## Related problems
- [Brown marks on a socket or plug](https://lightingelectrical.co.uk/problems/scorch-marks-on-socket): Brown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- [Burning plastic smell from electrics](https://lightingelectrical.co.uk/problems/burning-plastic-smell-electrical): A burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- [Burning smell from a socket](https://lightingelectrical.co.uk/problems/burning-smell-from-socket): A burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- [Burning smell from the fuse box](https://lightingelectrical.co.uk/problems/burning-smell-from-fuse-box): A burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- [Electric shock from a light switch](https://lightingelectrical.co.uk/problems/electric-shock-from-light-switch): A shock from a light switch means the switch face is carrying current and that lighting circuit should be isolated.
- [Electric shock from the shower](https://lightingelectrical.co.uk/problems/electric-shock-from-shower): A shock from the shower means current is on the water, the case or the taps, so that circuit stays off until it is tested.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [HSE: Electrical Safety at Work](https://www.hse.gov.uk/electricity/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)

Updated 2026-11-16.

[Emergency electrician](https://lightingelectrical.co.uk/services/emergency-electrician)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)