# Lights not working but sockets are fine

> In Peterborough, lights off with working sockets means the lighting circuit has opened. Lighting Electrical tests the breaker, switches and connections.

Lights off while the sockets still work means the lighting circuit itself has opened. Lighting Electrical in Peterborough tests that circuit at the board and along the cable until the failed switch, connection or breaker is named.

## Why are the lights off when the sockets still work?

The lights run on their own circuit, so a fault there leaves every socket working. The break is the lighting breaker, a switch, a dimmer or a connection in the lighting cable.
- **The lighting breaker has opened:** The lights have their own breaker in the fuse board, separate from the wider socket breakers. A short or an overload on the lighting cable opens that breaker. An RCBO, a breaker that also senses a leak to earth, opens on a leak and still leaves the sockets on.
- **A switch or a dimmer has failed:** A switch or a dimmer feeds its lamps on a cable that does not pass through any socket. The contacts inside fail and those lamps stay off. We fit the replacement from MK Electric, BG Electrical or Varilight.
- **A ceiling rose connection has opened:** A ceiling rose joins the fixed lighting cable to the flexible cord of the lamp. The lighting cable loops from one rose to the next. One loose screw in a rose puts out the lamps further along that loop.
- **A fitting has shorted the lighting cable:** A crushed cable in a downlight, a burnt lamp holder or rain in an outside lantern shorts the lighting cable. The lighting breaker opens on that short. The socket breakers stay up because they do not feed that fitting.
- **A connection on an added lighting cable has failed:** Each extra lamp joins the lighting cable at a new connection. A connection in the loft or above a ceiling opens through heat or movement. Lamps past that connection go dark. The sockets stay live on a different cable.

## What can I check when the lights are dead and the sockets work?

The safe checks are reading the breakers, trying the switches and changing one cool lamp. Every cover stays on and no cable is touched.
- **The lighting breaker behind a closed cover:** The lighting breaker is the narrow switch beside the wider socket breakers. Read it through the closed cover. Raise it once when it is down, the board is cool and there is no buzz. Leave it down if it opens again at once.
- **One floor dark or every light dark:** Turn on a light upstairs and a light downstairs. Darkness on one floor only means the lighting circuit for that floor has opened. Darkness on both floors, with the sockets live, means the lighting breaker has opened or the lighting cable is broken.
- **Both switches for the same light:** A two way light uses two switches for one lamp, one at each end of a stair or a landing. Click both switches. The lamp staying off points to those switches, the dimmer or the cable between them.
- **One new lamp in a cool fitting:** Switch the wall control off. Fit one new lamp in a fitting that feels cool. One dead lamp accounts for one dark point. A dark room or a dark floor needs more than a new lamp.

## When should I book if the lights are off but the sockets work?

Book Now if the lighting breaker will not stay up, a whole floor is dark, or a switch is hot or smells of scorching. A single spent lamp is not that fault.
- **The lighting breaker falls straight back down:** A breaker that opens again has a short or a leak to earth still on the lighting cable. More resets heat the breaker and the cable. Leave the breaker off so the sockets carry on.
- **One floor of lights will not come on:** A whole floor dark with live sockets is an open lighting circuit. A new lamp in one room leaves the other rooms on that floor dark. The circuit needs a test from the fuse board out to the last rose.
- **A switch or the board smells of scorching:** A hot switch, a buzz or a smell of scorching shows a failing connection on the lighting circuit. Use the front toggle to open the lighting breaker. Stay clear of the switch screws and of the board cover.
- **One switch makes the breaker open:** The lighting breaker opening each time one switch goes on means that switch, its dimmer or its cable is shorting. Leave that switch off. Rooms on a breaker that stays up keep their lights.

## What happens on the visit for dead lights and live sockets?

We start at the lighting breaker and test that circuit next. Any repair follows on the part the test names, after you accept it. The socket circuits stay on.
- **The dark rooms and the fuse board:** We ask which rooms went dark, which switches you tried and whether the lighting breaker is down. We stand at the closed fuse board with you and read every breaker. Live sockets show the socket breakers are closed. The main switch that feeds the board is closed too.
- **Dead tests on the lighting circuit:** We switch the lighting circuit off at its breaker. A dead test measures that cable while it is switched off. The reading shows a short, a break or a leak to earth. Socket circuits remain on throughout.
- **Each switch, rose and connection on the cable:** We take the covers off the switches and ceiling roses on the failed lighting run. Each connection is tested before we move along the cable. We name the failed switch, dimmer, connection or cable before a replacement is fitted.
- **Repair of the part that failed:** We fit the replacement switch, dimmer, connection or breaker after you accept the repair. We test the lighting circuit again and complete a minor works certificate, the record of that change. The breaker stays off when the circuit cannot be left live.

## What does a dead lighting circuit visit cost?

Electrical Fault Finding & Repair is priced by the hour when the lights are dead and the sockets are live. The price pays for tests at the fuse board and along the lighting circuit, the diagnosis, and repair of the failed part after you accept it. A single failed switch takes less time than an open connection on a dark floor. A replacement part, a minor works certificate or a fuse board replacement changes the price.
- Fault finding & repair: from £75 an hour
- We charge for a switch, a dimmer, a breaker or a length of cable only when the test shows it has failed.
- We write a separate price for fuse board replacement when the lighting breaker or the board has failed.
- We price emergency electrician attendance separately from a booked fault finding visit.

## Questions about lights off and sockets on

### Will a new fuse board fix lights that are off while sockets work?

A new fuse board goes in only when the test shows the lighting breaker or the board has failed. A board that passes the test stays in place when the fault is a switch, a dimmer or a ceiling rose connection. Fuse board replacement then has its own written price.

### Should I reset the lighting breaker more than once?

One reset shows whether a lamp or a switch was the cause. A breaker that opens again straight away needs a test of the lighting cable. Keep that breaker off and Book Now.

### Do my sockets stay on while the lights are repaired?

The sockets stay on because we switch off only the lighting breaker. We switch the lights back on after the failed part is repaired. The lighting breaker stays off if the circuit cannot be left live.

### What paperwork comes with a lighting circuit repair?

A repair that changes a switch, a dimmer, a connection or a breaker includes a minor works certificate. We issue that certificate under our NAPIT registration. The results of the tests on that circuit are written on it.

### Do you fit a new dimmer only after the test?

We test first and name the failed switch, dimmer, connection or breaker before a replacement is fitted. A Varilight, MK Electric or BG Electrical dimmer goes in only when the dimmer has failed. The repair is part of the fault finding visit after you accept it.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [IET: BS 7671 Guidance Publications](https://electrical.theiet.org/guidance-and-codes-of-practice/publications-by-category/bs-7671-and-guidance/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)