title: "Is my metal fuse box safe? | 4.7 Star · NAPIT approved · From £60"
description: "Metal fuse box safety in Peterborough rests on the devices, earthing and cables. Lighting Electrical inspects the board and leaves you a written EICR."
canonical: "https://lightingelectrical.co.uk/problems/metal-fuse-box"
---

# Is my metal fuse box safe?

> Metal fuse box safety in Peterborough rests on the devices, earthing and cables. Lighting Electrical inspects the board and leaves you a written EICR.

A metal fuse box is safe only when its devices, earthing and cables test sound. Lighting Electrical in Peterborough carries out an EICR and gives you that written record.

## Why is a metal fuse box not always safe?

The metal cover only slows fire that starts inside the board. The fuses or breakers, the earthing and the cables decide whether the fuse box is safe.
- **Rewirable fuses in an old metal case:** Many older metal fuse boxes still hold fuse wire rather than breakers. A breaker is a switch that opens when a circuit pulls too much current. Someone can fit thicker fuse wire that does not melt in time, and the cable overheats inside a case that still looks intact.
- **No RCD on the board:** An RCD is a switch that cuts the power when current leaks to earth. Earth is the path that carries a fault away from you. A metal fuse box with only fuse wire has no RCD, so a leak to earth does not open the circuit.
- **Loose terminals cooking the cables:** A loose terminal inside the board sparks and heats the ends of the cables. The metal cover can contain that heat better than a plastic one. It does not repair the loose joint or stop the copper from being damaged.
- **Earthing or bonding that is missing:** Earthing gives fault current a path back so a fuse or breaker can open. Bonding is the green and yellow link from metal gas and water pipes to the fuse board. A metal case that is not earthed stays live if a bare conductor touches it.
- **Extra circuits piled onto the same board:** Showers, cookers and extra sockets added on the same board crowd the terminals and load the main switch. The metal cover hides that crowding. Only an inspection shows whether the supply still has room for the load.

## What can I check without opening the fuse box?

You can read the front of the metal fuse box and press a test button if one is fitted. Keep the cover screwed on and keep your hands off the cables.
- **The name and the type of device:** Read the maker on the closed cover. Wylex, Hager, Contactum, BG Electrical and MK Electric all make metal boards. Fuse carriers with a piece of wire mean an old fuse box. Rocker switches mean breakers. You can see which you have without taking the cover off.
- **Whether an RCD test button is there:** Look for a button marked T or Test on the front. Press it once. The RCD should switch off and the power should drop, and you then switch it back on. If there is no button, or the button does nothing, stop there.
- **Heat, noise, smell or brown marks:** Hold the back of your hand near the cover and away from any bare metal edges. A warm cover, a buzz, a burning smell or brown marks at the rim mean a joint inside is overheating. Leave every screw in place.
- **Which circuits share one switch:** Watch what goes off when you press Test, or when one switch is already down. One switch killing the sockets and the lights means a single device covers the whole installation. You can see that with the cover shut.

## When should I book for a metal fuse box?

Book Now when the front of the board shows fuse wire, a dead test button, heat or a burning smell. Book Now too when a landlord or a buyer needs a current EICR.
- **Fuse wire or a test button that does nothing:** Rewirable fuses, or an RCD that stays up when you press Test, need an EICR. Another press will not repair the device. Book Now and leave the cover shut.
- **Heat, a buzz or a burning smell:** A warm cover, a buzzing board or a smell of hot plastic means a connection is failing inside the metal case. Use the main switch on the front if you need the power off. Do not undo screws. Book Now.
- **A landlord or a buyer needs an EICR:** Private rented homes in England need a current EICR. We also carry out an EICR when a buyer or a lender needs a current report on the installation. The metal fuse box is part of that inspection.

## What happens on a metal fuse box visit?

We inspect the metal fuse box, test the circuits and write the EICR. The power is off during the tests. A repair goes ahead only after you accept a separate price.
- **A look at the closed board:** We read the maker, the fuse carriers or breakers, and any brown marks on the cover with you there. You point out circuits that already trip. The cover stays on until the supply is isolated and a tester shows it is dead.
- **Tests on each circuit:** We switch the installation off and test each circuit. A continuity test checks the earth path. An insulation test checks whether current can leak between the wires. Where an RCD is fitted, we test that it trips, then we restore the power.
- **The EICR and any dangerous circuit:** We fill in the EICR on the visit and go through each C1, C2 and C3 item with you. C1 means danger is present, and we switch that circuit off before we go. C2 makes the report unsatisfactory. C3 notes an improvement, and the report can still be satisfactory.
- **A separate price if the board has failed:** If the tests show the metal fuse box has failed, we write a price for Fuse board replacement. That work sits outside the EICR. Before we write it, we check the earthing, the bonding and whether the supply can carry any further load.

## What does a metal fuse box inspection cost?

The price is for an EICR. It covers inspection of the metal fuse box, tests on the fixed wiring and a written report. More circuits, an outbuilding or a shop board change the price. Fuse board replacement and any other repair are quoted separately after the report.
- EICR (electrical safety report): from £150
- A house with a handful of circuits takes less time than a board that also feeds an outbuilding or a shop.
- Repairs sit outside the inspection price. We write a separate price for Fuse board replacement when the report shows the board has failed.
- We complete the EICR under our NAPIT registration and you keep the written report.

## Questions about metal fuse boxes

### Is a metal fuse box safer than a plastic one?

A metal case stands up to fire better than an old plastic case. A new consumer unit in a home must use a non combustible enclosure, which means the case must not catch fire. A consumer unit is the modern fuse board. The metal still says nothing about the fuse wire, the RCD or the terminals, so we record those on an EICR.

### Do I have to replace my metal fuse box?

No. The non combustible enclosure rule applies when a consumer unit is newly fitted in a home. An existing metal board stays when the EICR shows the devices, earthing and cables are sound. We price Fuse board replacement only when the report shows the board itself has failed, and other repairs are priced on their own.

### What paperwork do I receive after the inspection?

You receive the EICR. It lists the circuits, the tests and the result for the installation. Where we later change a circuit, the Minor works certificate covers that change under our NAPIT registration. The inspection price does not include that later repair.

### Can I fit thicker fuse wire in a metal fuse box?

No. Thicker fuse wire hides an overload and lets the cable heat up. Leave the wire that is already there and leave the cover on. Book Now so we can test the circuit and fit the right protection if it has failed.

### Will the power stay on while you test?

No. We switch the supply off while we test the metal fuse box and the circuits. We restore power when those tests are done. A circuit that is dangerous stays off.

## Related problems
- [Aluminium wiring in the house](https://lightingelectrical.co.uk/problems/aluminium-wiring): Aluminium cable overheats at loose joints. We test it, write the electrical installation condition report, and price any copper replacement separately.
- [Buying a house with old electrics](https://lightingelectrical.co.uk/problems/buying-house-old-electrics): An EICR sets out the condition of old electrics before you buy, circuit by circuit.
- [House not up to electrical regulations](https://lightingelectrical.co.uk/problems/house-not-up-to-electrical-regs): An EICR names the parts of the fixed wiring that fall short of the current rules, and repairs are priced afterwards.
- [How to tell if a house needs rewiring](https://lightingelectrical.co.uk/problems/signs-house-needs-rewiring): The house needs rewiring when an EICR shows the cables or the fuse board cannot be made safe by repairing one circuit.
- [No electrical certificate for the property](https://lightingelectrical.co.uk/problems/no-electrical-certificate): An EICR of the fixed wiring replaces a missing electrical certificate and leaves you the written report.
- [Part P non compliance: what to do](https://lightingelectrical.co.uk/problems/part-p-non-compliance): Unnotified or unsafe fixed wiring in a home is Part P non compliance. We inspect it and issue a written EICR.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [IET: BS 7671 Guidance Publications](https://electrical.theiet.org/guidance-and-codes-of-practice/publications-by-category/bs-7671-and-guidance/)
- [Electrical Safety First: Best Practice Guides](https://www.electricalsafetyfirst.org.uk/resources-for-electricians/best-practice-guides/)

Updated 2026-11-16.

[EICR](https://lightingelectrical.co.uk/services/eicr)

## Book or ask a question