# Neighbours have power but I don't

> No power while neighbours stay lit means a tripped main switch or a dead service fuse. Lighting Electrical of Peterborough tests which has opened.

A dark house while next door stays lit has a tripped main switch, a blown service fuse or a meter that has cut the supply. Lighting Electrical tests those three points from its Peterborough base.

## Why is the house dark when the neighbours have power?

The property loses power on its own when the main switch trips, the service fuse blows or the meter switches the supply off.
- **The main switch or main RCD has tripped:** A tripped main RCD or main switch cuts every circuit at once. An RCD is the safety switch that shuts off if electricity leaks away from a circuit. Where that switch feeds the whole board, one leak puts every room into darkness. A heavy short on a socket circuit drops the main switch as well.
- **The service fuse has blown:** A blown service fuse cuts power to the meter and the fuse board together. The service fuse is the network operator's cartridge in the sealed holder beside the meter. Next door stays on because that fuse serves this property alone.
- **The meter has switched the supply off:** A prepayment meter cuts the supply when the credit runs out. A smart meter cuts the supply when the supplier disconnects it. The meter screen states the reason. The fuse board receives no live feed until the meter closes.
- **Burnt meter tails or a burnt main switch:** A burnt joint in the meter tails or the main switch opens and the property goes dark. Meter tails are the thick cables that link the meter to the fuse board. Scorch marks, heat or a smell of burning at the board show that this connection has failed.
- **A separate isolator has failed:** A failed or switched off isolator leaves the fuse board dead while the meter stays live. An isolator is a switch fitted between the meter and the fuse board. It disconnects live and neutral together.
- **The cable from the street main has failed:** A failed service cable leaves this meter dead while neighbouring homes stay lit. The service cable brings power from the street main to this property only. The network operator repairs that cable.

## What checks are safe when next door still has power?

You can read the main switch, the meter screen and any separate isolator with the covers left on. No screw comes out and no cable is touched.
- **Read the main switch:** The main switch position shows whether the whole board has been switched off. Look at the fuse board with the lid left closed. The main switch is the widest one on the board. It feeds every circuit in the property. Lift it once if it is down and the board is cool and quiet. Leave it down if the power drops straight away.
- **Read the electricity meter:** A message about credit or disconnection means the meter has opened the supply. Top up a prepayment meter or speak to the supplier. A meter with no lights and no screen points to the service fuse.
- **See if every circuit is dead:** Every circuit being dead places the break ahead of the individual breakers. Try one light upstairs, one kitchen socket and the boiler switch. One room still working means only that circuit has dropped.
- **Compare the lights next door:** Steady lights next door mean the street mains are up. This property has lost its own supply. Ask one neighbour whether their lights are steady and at normal brightness. Dim, bright or flickering lights in both homes go to 105, the free power cut line.
- **Notice heat, noise or smell:** Heat, noise or a burning smell means a joint is failing. Pause beside the fuse board and the meter. Leave every switch where it is and keep clear of the board.

## When is an electrician needed for one dark house?

Book Now when the main switch will not stay up, the meter is live while the house is dark, or the board smells of burning.
- **The main switch will not hold:** Another trip after the plugs are pulled means leakage on the fixed wiring or a worn main RCD. Repeated resets heat the switch and the cables. The visit tests each circuit and leaves the bad one off.
- **The meter is live but the house is dark:** Lights on the meter and no power in any room mean the supply stops in the tails, the isolator or the main switch. Those parts sit under covers. A tester has to show those cables are dead before a cover comes off.
- **The board is hot, buzzing or smelling:** Heat, a buzz or a burning smell at the meter or the fuse board means a joint is breaking down. Put the main switch down from the toggle on the front. Keep your hands off the cables and the cover.
- **The meter is dark as well:** A blank meter and a dark house point to the service fuse or the service cable. We confirm that with a voltage test on the incoming terminals. The network operator then changes the fuse or repairs that cable.

## What happens on the visit for a fully dark house?

The visit runs from the meter to the main switch and then through each circuit. Any failed part stays isolated at the end.
- **Voltage test at the meter:** A voltage test at the meter shows whether any supply is arriving. We read the meter screen with you. A tester then checks for voltage on the supply coming into the property. No voltage means the service fuse or the service cable has failed. The seals stay untouched.
- **Tests on the tails and the main switch:** Live voltage at the meter with a dead fuse board moves the test to the isolator, the meter tails and the main switch. A burnt or open joint shows between those points. We leave the failed joint disconnected while testing carries on.
- **Finding the circuit that drops the main RCD:** Every breaker goes off before we close the main RCD. Each circuit then comes back on its own. The one that drops the RCD stays off. A further test separates a damp fitting, a damaged cable and a failed RCD.
- **Sound circuits back on and the next job priced:** Circuits that hold remain on. The kitchen and the heating run again where their own circuit held. One failed circuit stays off. Before we price a repair, we check earthing, bonding and spare capacity in the supply. The Minor works certificate covers a change to a breaker, a switch or a cable. Fuse board replacement carries its own written price.

## What does a single house power loss visit cost?

Emergency electrician pricing is the time spent at the property. That time covers attendance and the voltage tests. Switching the failed part off is included in that time. A main RCD that holds once the bad circuit is off takes less time than burnt meter tails. We write a parts price for burnt tails before fitting them.
- Emergency electrician (out of hours): from £90 an hour
- We write up a new main switch, RCD or run of meter tail from Hager, Wylex, Contactum, BG Electrical or MK Electric before fitting it.
- The emergency electrician rate applies outside opening hours and the fault finding rate applies during opening hours.
- Fuse board replacement gets its own written price when the existing board cannot be left safe.

## Questions about no power when neighbours still have it

### Is it a power cut if my neighbours have electricity?

A network power cut drops neighbouring homes at the same time. Power still on next door means the main switch, the service fuse or the meter on your supply has opened. We test those three and name the one that failed.

### Should I call 105 or book an electrician?

Call 105 when next door is dark or the street lights are out as well. Book Now when next door is normal and your house alone is dead. We test the incoming supply. A failed service fuse goes to the network operator.

### Will the kitchen work again before the repair is finished?

The kitchen comes back where the main switch holds with the failed circuit switched off. Healthy circuits go back on. The kitchen returns with them when its circuit is healthy. A blown service fuse keeps the whole house off until the network operator changes it.

### Do you change the fuse board on the same visit?

Fuse board replacement happens on the visit only after you accept a written price and the board can be left safe. The failed circuit stays off until the new board has its own price. We test the work we complete before we leave the property.

### What paperwork do I get after a repair?

A change to a breaker, a switch or a cable includes a minor works certificate for that circuit. Lighting Electrical is NAPIT registered. The test results are written on the certificate. Isolation with no alteration leaves a written note of the failed part and the readings.

## Related problems
- [Brown marks on a socket or plug](https://lightingelectrical.co.uk/problems/scorch-marks-on-socket): Brown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- [Burning plastic smell from electrics](https://lightingelectrical.co.uk/problems/burning-plastic-smell-electrical): A burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- [Burning smell from a socket](https://lightingelectrical.co.uk/problems/burning-smell-from-socket): A burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- [Burning smell from the fuse box](https://lightingelectrical.co.uk/problems/burning-smell-from-fuse-box): A burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- [Electric shock from a light switch](https://lightingelectrical.co.uk/problems/electric-shock-from-light-switch): A shock from a light switch means the switch face is carrying current and that lighting circuit should be isolated.
- [Electric shock from the shower](https://lightingelectrical.co.uk/problems/electric-shock-from-shower): A shock from the shower means current is on the water, the case or the taps, so that circuit stays off until it is tested.

## Sources
- [UK Power Networks: Power Cut Help](https://www.ukpowernetworks.co.uk/power-cut)
- [Energy Networks Association: Power Cut Information](https://www.energynetworks.org/operating-the-networks/power-cuts)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)

Updated 2026-11-16.