---
title: "No electrical certificate for the property | 4.7 Star · NAPIT"
description: "No electrical certificate in Peterborough means the fixed wiring lacks a current EICR. Lighting Electrical inspects the circuits and leaves a written…"
canonical: "https://lightingelectrical.co.uk/problems/no-electrical-certificate"
---

# No electrical certificate for the property

> No electrical certificate in Peterborough means the fixed wiring lacks a current EICR. Lighting Electrical inspects the circuits and leaves a written…

A property with no electrical certificate needs an Electrical Installation Condition Report, called an EICR, of the fixed wiring. Lighting Electrical in Peterborough inspects those circuits and leaves the written report.

## Why is there no electrical certificate?

There is no electrical certificate when the fixed wiring has never had an EICR, or the last report is lost or out of date.
- **No inspection on record:** An EICR is the report that records a full inspection of the fixed wiring. Without that inspection the property has no certificate for a tenancy, a sale or an insurer.
- **The report was lost:** A move, a change of letting agent or a clear out beside the meter often takes the only copy. The wiring may be fine, yet you have no dated report to pass on.
- **A rented home is out of date:** Private rented homes in England need a current EICR, usually every five years. A change of tenancy also needs one when the previous report has run out. An expired report leaves the let without a current certificate.
- **Later electrical work has no paper:** A new circuit, a fuse board change or a rewire should have its own certificate for that job. A minor works certificate covers only a small change on an existing circuit. Neither document is an EICR of the whole installation.
- **Nothing written on the fuse board:** The fuse board often carries the date of the last inspection on the outside of the cover. A blank front, or a date older than five years on a let home, means there is no current certificate to hand over.

## What can I check safely at home?

You can search the paperwork, read the date on the closed fuse board, and note whether the home is let, for sale, or recently altered.
- **The sale pack and the tenancy file:** Look in the solicitor papers, the landlord folder and any sleeve by the meter. The document you need is an Electrical Installation Condition Report. A single minor works certificate records one small job only.
- **The date on the closed fuse board:** Leave every screw in place. Read the inspection date on the front of the fuse board. No date, or a date older than five years on a rented home, means you do not hold a current certificate.
- **A let, a sale or a lender ask:** A private let needs the report for the tenancy. Solicitors and lenders often ask for the same report before exchange. The request is for an EICR of the fixed wiring.
- **New fittings since the last report:** Note a new electric shower, a cooker circuit or a replacement fuse board. Each of those jobs should have had its own certificate. The EICR still inspects the whole installation, including that newer work.

## When should I book for a missing certificate?

Book Now when you have no current EICR, the last one has run out, or a tenancy, a sale or an insurer is waiting for the report.
- **The let has no current report:** Book Now if you cannot find an EICR for a private rented home. Also book when five years have passed, or the last report ran out as the tenants changed. The new report is what goes in the tenancy file.
- **A sale or remortgage needs the report:** Book Now when the solicitor or the lender has asked for an electrical safety report and the pack has none. The inspection gives them a dated EICR of the fixed wiring.
- **New work never came with paperwork:** Book Now when a fuse board, a rewire or a new circuit was fitted and no certificate was left for it. The EICR covers the whole installation. Repairs the report finds are priced afterwards.

## What happens on the certificate visit?

We inspect and test the fixed wiring, then leave a written EICR. That report is the certificate the property did not have.
- **The fuse board and the rooms:** We confirm the property and look at the fuse board, also called the consumer unit. A Hager, Wylex, Contactum, BG Electrical or MK Electric board is inspected in the same way as any other. You can show any old report, a new shower or cooker circuit, and a breaker that already trips.
- **Circuit tests with power off in turn:** We isolate the supply and test each circuit in turn. Dead tests measure the cable while the power is off. They include earth continuity, the unbroken safety path back to the board, and insulation resistance, which shows current leaking between the conductors. We restore power to each circuit as its test finishes.
- **Codes on the written report:** We finish the EICR during the visit and talk through every code. A C1 item is danger now, so we make that circuit safe before we go. A C2 item is potentially dangerous and fails the report. A C3 item is a recommended improvement and does not fail the report on its own. FI means further investigation before that item can be coded.
- **Repairs only after you accept them:** You keep the EICR. If it is unsatisfactory we quote the repairs in writing, and that price is separate. Fuse board replacement is quoted on its own when the tests show the board has failed. Before any further price we check earthing, bonding (the link from metal pipes to that earth), and whether the supply can carry another load.

## What does a missing certificate inspection cost?

The price covers a full inspection and test of the fixed wiring and the written EICR we leave you. It is set for a typical house. More circuits, an outbuilding or a commercial layout add time and change the price. Repairs are not included. We quote those after the report, and a fuse board replacement is a separate job when the board has failed.
- EICR (electrical safety report): from £150
- A small flat needs less time on site than a large house or a workplace with many circuits.
- Newer circuits with no certificate stay inside the same EICR. House Rewiring is a separate quote, and only if you ask for it after the report.
- Our NAPIT registration covers the inspection, and the EICR is the paperwork from the visit.

## Questions about a missing electrical certificate

### Is an EICR the same as the missing certificate?

Yes, when someone wants a report on the whole fixed wiring. The EICR lists every circuit, the tests and the overall result. A minor works certificate only records one small alteration, so it does not replace that report.

### Do I need to stay while the power is off?

Yes. Someone who can let us in has to stay while the power is off for the tests. A tenant can stay if the landlord arranged the visit. Each circuit is off only while we test it, then the power comes back.

### Will faults be repaired on the same visit?

The visit produces the inspection and the written EICR, not the repairs. An unsatisfactory report is followed by a written quote for the work. You can have that work done with us or take the report to another electrician.

### How often does a rental need a new EICR?

A private rented home in England needs a current EICR. The usual gap is five years, and a new tenancy needs a report too if the last one has expired. Every inspection we do ends with a new written report.

### What if the EICR comes back unsatisfactory?

C1 and C2 observations make the result unsatisfactory. We leave a C1 circuit safe before we go, and we quote the other repairs in writing. C3 items do not fail the report by themselves.

## Related problems
- [Aluminium wiring in the house](https://lightingelectrical.co.uk/problems/aluminium-wiring): Aluminium cable overheats at loose joints. We test it, write the electrical installation condition report, and price any copper replacement separately.
- [Buying a house with old electrics](https://lightingelectrical.co.uk/problems/buying-house-old-electrics): An EICR sets out the condition of old electrics before you buy, circuit by circuit.
- [House not up to electrical regulations](https://lightingelectrical.co.uk/problems/house-not-up-to-electrical-regs): An EICR names the parts of the fixed wiring that fall short of the current rules, and repairs are priced afterwards.
- [How to tell if a house needs rewiring](https://lightingelectrical.co.uk/problems/signs-house-needs-rewiring): The house needs rewiring when an EICR shows the cables or the fuse board cannot be made safe by repairing one circuit.
- [Is my metal fuse box safe?](https://lightingelectrical.co.uk/problems/metal-fuse-box): A metal cover does not make a fuse box safe. The devices, earthing and cables settle that, and an EICR records the result.
- [Part P non compliance: what to do](https://lightingelectrical.co.uk/problems/part-p-non-compliance): Unnotified or unsafe fixed wiring in a home is Part P non compliance. We inspect it and issue a written EICR.

## Sources
- [Electrical safety standards for rented homes](https://www.gov.uk/government/publications/electrical-safety-standards-in-the-private-and-social-rented-sectors-guidance/electrical-safety-standards-in-the-private-and-social-rented-sectors-guidance)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Best Practice Guide 4](https://www.electricalsafetyfirst.org.uk/media/2depcuen/best-practice-guide-4-issue-6.pdf)

Updated 2026-11-16.

[EICR](https://lightingelectrical.co.uk/services/eicr)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)
