# No power in the whole house

> No power in the whole house: what to check first, and when a Peterborough electrician should test the fuse board and make your home safe again.

Check the street first: if your neighbours are dark too, it is a power cut. If only your home is off, Lighting Electrical in Peterborough tests the board and puts back every circuit that reads safe.

## Why has the power gone off in the whole house?

Whole house outages come from a short list: the network outside, the main fuse, the meter, or a switch at your fuse board that has cut everything at once.
- **A power cut on the local network:** If the neighbours and the street lights are dark too, the fault is on the network outside your home. The network operator repairs it, and nothing inside the house needs touching.
- **An RCD tripped by a faulty appliance:** An RCD, or residual current device, is a switch on the fuse board that cuts power when current leaks to earth. A failed kettle, washing machine or damp outdoor socket can trip it. On some boards one RCD covers every circuit, so one leak darkens the whole house.
- **The main switch has tripped or worn out:** The main switch turns off everything at the consumer unit, which is the fuse board. Some main switches carry their own RCD. A worn one can refuse to latch back on.
- **The main fuse has blown:** The main fuse sits in a sealed box beside the meter and belongs to the network operator. When it blows, every switch on the board still looks normal. Only the operator replaces it.
- **A prepayment meter out of credit:** A prepayment meter stops the supply once the credit and any emergency credit run out. Every breaker stays up while the house sits dark.
- **A burnt connection at the meter or board:** Meter tails are the thick cables between the meter and the fuse board. A loose connection on them heats up and can break the supply to the whole house. Scorch marks or a burning smell near the board point to this.

## What can I safely check before calling anyone?

You can check the street, the switches on the front of the board and the meter screen. Leave every cover in place and never touch the sealed fuse box.
- **Look outside at the street:** See whether your neighbours have lights and whether the street lights are on. If they are dark too, call 105, the free power cut number, and leave the board alone.
- **Look at the switches on the fuse board:** Without removing any cover, see whether the main switch or an RCD has dropped to off. Push it back up once.
- **Unplug everything and reset again:** If the RCD drops again, switch off and unplug every appliance, then reset it. Plug things back in one at a time. Whatever trips it again stays unplugged.
- **Read the meter display:** A prepayment or smart meter shows the remaining credit on its screen. Topping up or taking emergency credit brings the supply back.

## When should I book an electrician for no power?

Book when the street has power and the meter has credit, but your switches will not stay up and no single appliance is to blame.
- **The RCD or main switch will not stay on:** A switch that drops straight back with everything unplugged points to a fault in the fixed wiring. That needs testing with instruments, not more resets.
- **Heat, scorching or a burning smell at the board:** Leave the board off and keep clear of it. Damage at the sealed fuse box or the meter goes to the network operator on 105. Damage at the board or the tails needs an electrician.
- **Your neighbours have power and you have none:** With credit on the meter and every switch up, the break is between the network and your board. A test at the board shows which side of the meter it is on.
- **Water has reached sockets, lights or the board:** Keep the power off after a leak or a flood. Wet circuits need drying and testing before anyone switches them back on.

## What happens when the electrician arrives?

We start at the board, confirm the supply reaching it, then test circuit by circuit until the readings show what cut the power.
- **Questions and a look over the board:** We ask what happened just before the power went and what you have already tried. Then we look over the board, the meter and the tails for signs of heat.
- **Testing the incoming supply:** We measure the supply at the incoming terminals of the board. No supply there means the main fuse or the network, and you call 105 with what we measured.
- **Splitting the circuits:** With the supply confirmed, we disconnect circuits and run insulation resistance tests. These measure current leaking through damaged cable or a wet fitting, and the failing circuit shows in the readings.
- **Making safe and the next step:** Sound circuits go back on and the faulty one stays isolated. A small repair is finished on the visit when the part is on hand. Larger work gets a written price before it starts.

## What does an emergency call for no power cost?

The cost covers getting to you, testing to find what cut the supply, and making the house safe. Time on site moves it most, so one tripping appliance costs less than a fault buried in the wiring.
- Emergency electrician (out of hours): from £90 an hour
- Parts such as a new main switch, RCD or socket are added on top of the labour.
- A new consumer unit or a damaged cable run is priced in writing before any of that work starts.
- An empty meter or a network power cut needs no electrician, so checking the street and the meter first can save you a visit.

## Questions about having no power

### Is it a power cut or a fault in my house?

Look outside. Dark street lights and dark neighbours mean a network power cut, so call 105. Lights next door and none at yours means the problem is at your meter, main fuse or board.

### Who replaces the main fuse?

The network operator owns the main fuse in the sealed box beside the meter. Call 105 and they send someone to replace it. Nobody else should break that seal.

### Is it safe to keep resetting the RCD?

Resetting once or twice with everything unplugged is a fair test. If it trips straight away again, leave it off. Something on the fixed wiring is leaking current and needs testing.

### Can you fix it on the same visit?

A failed RCD, a scorched socket or a loose connection can be repaired on the visit when the part is on hand. Bigger work, such as a new consumer unit, is priced in writing and booked for another day.

### Do I get paperwork after the repair?

A repair that alters a circuit comes with a minor works certificate. We are NAPIT registered, and that registration covers the certificate.

## Related problems
- [Brown marks on a socket or plug](https://lightingelectrical.co.uk/problems/scorch-marks-on-socket): Brown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- [Burning plastic smell from electrics](https://lightingelectrical.co.uk/problems/burning-plastic-smell-electrical): A burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- [Burning smell from a socket](https://lightingelectrical.co.uk/problems/burning-smell-from-socket): A burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- [Burning smell from the fuse box](https://lightingelectrical.co.uk/problems/burning-smell-from-fuse-box): A burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- [Electric shock from a light switch](https://lightingelectrical.co.uk/problems/electric-shock-from-light-switch): A shock from a light switch means the switch face is carrying current and that lighting circuit should be isolated.
- [Electric shock from the shower](https://lightingelectrical.co.uk/problems/electric-shock-from-shower): A shock from the shower means current is on the water, the case or the taps, so that circuit stays off until it is tested.

## Sources
- [Power Cut 105: Energy Networks Association](https://www.powercut105.com/)
- [UK Power Networks: Power Cut Help](https://www.ukpowernetworks.co.uk/power-cut)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)

Updated 2026-11-16.