title: "No electricity in one room | 4.7 Star · NAPIT approved · From £60"
description: "No electricity in one room in Peterborough? Lighting Electrical traces the dead circuit at the board and along the wiring, then repairs the fault it finds."
canonical: "https://lightingelectrical.co.uk/problems/no-power-in-one-room"
---

# No electricity in one room

> No electricity in one room in Peterborough? Lighting Electrical traces the dead circuit at the board and along the wiring, then repairs the fault it finds.

When one room goes dead and the rest of the house works, the fault sits on the circuit feeding that room. Lighting Electrical in Peterborough tests that circuit until the readings name the failed breaker, socket or joint.

## Why has one room lost its power?

Each room draws power from at least two circuits, one for lights and one for sockets. When one room goes dark, something has broken on one of those circuits, at the board or along the cable.
- **A tripped breaker on that circuit:** Every circuit has its own switch, called a breaker, on the consumer unit, which is the fuse board. The breaker drops when the circuit overloads or leaks current to earth. Every light or socket on that circuit goes off with it.
- **Lights and sockets on separate circuits:** A room takes its lights from one circuit and its sockets from another. When only the lights or only the sockets have died, the fault belongs to that one circuit. The same circuit can also feed rooms you have not tried yet.
- **A loose terminal at a socket:** A radial circuit is one cable running from socket to socket and ending at the last. A loose or burnt terminal at one socket cuts power to every socket beyond it. The breaker stays up while the room sits dead.
- **A failed joint in a junction box:** Lighting cables meet in junction boxes, small round connectors under the floor or in the loft. A joint that works loose stops the lights in one room while every switch on the board looks normal.
- **A nail or screw through a cable:** A shelf bracket, picture hook or floorboard nail driven through a cable can break it or let current leak to earth. The room goes dead the day that fixing went in.

## What can I check before calling an electrician?

You can look at the board, try the room's lights and sockets, and unplug appliances. Keep every cover on, and never open a socket, a switch or the board itself.
- **Find the breaker that has dropped:** Without taking any cover off, look along the board for one switch sitting lower than the rest. Push it back up once and see whether the room comes back.
- **Unplug the room and reset again:** If that breaker drops straight away, unplug everything in the room and push it up again. Reconnect each item in turn. The one that brings the trip back stays unplugged.
- **Work out which points are dead:** Try the ceiling light, then each socket with a lamp you know works. Dead lights with live sockets, or the reverse, shows the electrician which circuit to test first.

## When does a dead room need an electrician?

Book when the room stays dead after a single reset, when every breaker is up and nothing works, or when anything in the room shows heat.
- **The breaker will not stay up:** A breaker that drops again with the whole room unplugged points to the fixed wiring. Leave it off and book a test of the circuit.
- **Every breaker is up and the room is still dead:** That points to a loose terminal or a failed joint somewhere along the circuit. Only testing along the cable finds where it is.
- **A socket or switch is warm, buzzing or smells:** Switch that circuit off at the board and leave it off. Heat at a faceplate means a connection is burning behind it.
- **The room died after drilling or fixing into a wall:** Keep the breaker off. A cable damaged inside the wall stays dangerous even while the room looks dead.

## What happens on a fault finding visit?

The visit starts at the board and works outward along the dead circuit, testing at each point until the failed part is found.
- **What happened and a look at the board:** We ask when the room went dead and what was running at the time. Then we find the breaker that feeds the room and check its position.
- **Testing the circuit from the board:** With the circuit isolated, we run continuity and insulation resistance tests. An insulation resistance test shows current escaping through damaged cable or a wet fitting.
- **Tracing the break along the cable:** We open sockets, switches or junction boxes along the circuit, working from the last live point to the first dead one. That narrows the fault to a loose terminal, a burnt joint or a damaged length of cable.
- **Repair, retest and paperwork:** Once you say yes to the repair, we fix that fault and retest the circuit before switching it back on. A circuit that cannot be left live that day stays isolated. A minor works certificate follows when the repair alters the circuit.

## What does tracing a dead circuit cost?

The hourly rate pays for time on site: testing at the board, tracing the circuit, a spoken diagnosis and the repair once you say yes. A loose terminal near the board takes less time than a cable damaged inside a wall, so where the break sits moves the cost most.
- Fault finding & repair: from £75 an hour
- Replacement parts, such as a breaker, a socket or a junction box, are added to the labour.
- A minor works certificate is added when the repair alters the circuit.
- If the tests point to a new board or a rewire, that work gets its own written price before it starts.

## Questions about a room with no power

### Why do my sockets work but the lights in that room are dead?

Lights and sockets run on separate circuits. Dead lights with live sockets point to the lighting breaker, a switch or a loose joint in a junction box. Testing the lighting circuit shows which.

### Will you just swap the breaker?

No. A breaker that keeps tripping is doing its job, so a new one would hide the fault. We test the circuit first and replace the breaker only when the readings show it has failed.

### Can I run an extension lead from another room until it is fixed?

A lead from a working room is fine for a lamp or a phone charger. Keep heaters and kettles off it. Leave the dead circuit switched off until it has been tested.

### Will the rest of the house stay on while you work?

Yes. Only the dead circuit is isolated while it is tested and repaired. The other rooms keep their lights and sockets.

### Do I get a certificate for the repair?

Yes, when the repair alters the circuit, such as a new socket, breaker or joint. The minor works certificate records the tests on that circuit and is issued under our NAPIT registration.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [NICEIC: Householder Guidance](https://niceic.com/householders/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)