# Old fuse box: do I need to upgrade?

> Old fuse box upgrade in Peterborough: Lighting Electrical replaces a rewirable fuse board with a consumer unit and tests every circuit that leaves it.

An old fuse box needs replacing when it still holds rewirable fuse wire or has no residual current device. Lighting Electrical in Peterborough fits a consumer unit and tests each circuit from it.

## Why does an old fuse box need an upgrade?

An old fuse box needs an upgrade when fuse wire or a missing safety switch leaves a leak or an overload on the circuit. How old the property is does not decide the upgrade on its own.
- **Fuse wire instead of a breaker:** A rewirable fuse is a short length of fuse wire in a carrier. The wire melts on a heavy overload. A small leak to earth can leave that fuse intact, so the circuit stays live. A breaker opens the same circuit with a switch you can reset.
- **No residual current device:** A residual current device, called an RCD, switches off when current leaks from the circuit to earth. Earth is the safety path that carries a fault away from you. Many older boards have no RCD, so a damaged lead or a wet socket does not cut the power.
- **A full board with no spare way:** Each circuit needs its own way, which is one space on the board. An electric shower, an EV charger or extra kitchen sockets need a free way. A full fuse box cannot take that circuit until a larger consumer unit is fitted.
- **A cracked or scorched case:** Heat from a loose terminal cracks a plastic or wooden case and leaves brown marks around the carriers. That case no longer holds a fault inside the board. The cover stays on until we isolate the supply and remove the unit.
- **An EICR that flags the board:** An Electrical Installation Condition Report, called an EICR, records missing RCD cover, damaged metal bars inside the board, or names that no longer match the circuits. We replace the unit when that report shows the board has failed those checks.

## What can you check on an old fuse box?

You can look at the closed cover, the carriers and the test button. Leave every screw in place and keep your hands off the cables.
- **Fuse wire or breakers on the front:** Look through the cover. Carriers that pull out and take fuse wire are an old fuse box. Small switches that click up and down are breakers. You leave every carrier in and you leave the cover shut.
- **Whether an RCD test button is there:** An RCD has a button marked T or Test on the front of the closed board. Press it once. If the switch drops, those circuits go off and you reset the switch. If the switch stays up, that RCD is not opening.
- **Heat, a smell or brown marks:** A warm cover, a buzz or a smell of burning means a joint inside is failing. Brown marks around a carrier mean the same. Leave the cover shut. Use the main switch on the front only if you can reach it without taking the cover off.
- **Spare spaces and the circuit names:** Read the names printed on the front. Every space filled means there is no spare way for a shower, a charger or more sockets. A name that does not match the room shows the board has been altered. You only read the front.

## When should you book an old fuse box upgrade?

Book Now when fuse wire keeps blowing, the board is hot or cracked, or an EICR asks for a new consumer unit. A board that is cool, quiet and already fitted with RCD protection can stay.
- **Fuse wire blows more than once:** The same lights or sockets die again after one new piece of fuse wire. The fault is still on the circuit. Further wire hides that fault and heats the carrier, so the circuit stays unused.
- **The board is hot, cracked or smells:** Heat, a crack or a burning smell at the fuse box means a terminal is arcing. Arcing is a spark across a loose joint. Book Now and leave the cover screws in place.
- **A report or a new circuit needs a new board:** An EICR that records no RCD cover means the fuse box should be changed. A shower, a charger or a cooker with nowhere to connect needs a larger consumer unit. Fuse board replacement is a separate written price from any new circuit.

## What happens on an old fuse box visit?

We isolate the supply, fit the consumer unit and test the circuits that leave it. The power stays off from isolation until those tests are finished.
- **The price, the tails and isolation:** We confirm the written price with you. We look at the meter tails, the thick cables between the meter and the fuse box. We then isolate the incoming supply. Items stored in front of the cupboard need to be moved before that isolation.
- **The old board comes off:** We remove the old fuse box. We fit a consumer unit from Hager, Wylex, Contactum, BG Electrical or MK Electric to match the circuits. We connect the tails and the earth, place each circuit on its breaker, and mark each way.
- **Tests, power back and the certificate:** We test continuity, insulation and the RCD or RCBO. An RCBO is a breaker and an RCD together for one circuit. We restore the supply. We then check the lights and sockets. Replacing a fuse board is notifiable work, so we issue the certificate and notify it through NAPIT.
- **Circuits that fail the tests:** A scorched conductor or a poor earth reading stays as separate work with its own written price. Before that price we test the earth path and the bonds to metal pipes, and we check the supply can carry another load. Earthing is the fault path back to the board. Bonding is the link from those pipes to the earth.

## What does an old fuse box upgrade include?

Fuse board replacement covers taking out the old fuse box, fitting a consumer unit with RCD or RCBO protection, and testing the circuits that run from it. A larger board, a steel case or a low cupboard changes the price. Scorched cables or a circuit that fails its test are written as further work. We confirm the written price before isolation.
- Consumer unit replacement: from £450
- The price covers the board change and the tests on the circuits that leave the new consumer unit.
- A steel case, more ways, or a board in a low cupboard changes the price.
- A shower, a charger or extra sockets are a separate job from the board change.

## What do householders ask about an old fuse box?

### Do I need an upgrade if the fuse wire still works?

Yes, if the board has no RCD, because fuse wire does not open on a small leak to earth. A board that already has RCD or RCBO protection and passes its tests can stay. We say which applies after we see the closed cover and, where you have one, the EICR.

### Will you replace a board that still has fuse wire?

Yes. We remove the rewirable fuse box and move the existing circuits onto breakers with RCD or RCBO protection. The supply stays off until the new consumer unit is tested, and you get the certificate for that change.

### Do I get paperwork for a new consumer unit?

Yes. Replacing a fuse board is notifiable electrical work, which means the job is reported to the local authority. We issue the electrical certificate and notify it through our NAPIT registration. A circuit we switch off and do not change is written up from the test readings.

### Can you change a fuse board in a rented house?

Yes. Landlords ask us after an EICR or when fuse wire keeps failing. We confirm the written price before isolation. The occupant clears the cupboard so we can reach the board.

### Will a new consumer unit cure every dead circuit?

A new consumer unit restores a circuit only when the failed part is the board itself. A damaged cable, a scorched socket or a leaking appliance still needs its own repair, written separately. We name that part from the test results before we price it.

## Related problems
- [Fuse box in the bathroom: is it legal?](https://lightingelectrical.co.uk/problems/fuse-box-in-bathroom): A consumer unit inside a bathroom is not permitted and has to be moved outside that room.
- [Signs your fuse box needs upgrading](https://lightingelectrical.co.uk/problems/fuse-box-needs-upgrading): A fuse box needs upgrading when it has fuse wire, no RCD, no spare ways, or a hot scorched cover.
- [Still got rewirable fuses?](https://lightingelectrical.co.uk/problems/rewirable-fuses): A rewirable fuse box relies on fuse wire and has no residual current device, so the board is replaced and every circuit is tested.
- [Unsatisfactory EICR: what happens next?](https://lightingelectrical.co.uk/problems/failed-eicr): An unsatisfactory EICR means a C1, a C2 or further investigation needs remedial work, and Lighting Electrical writes a price for those repairs.
- [Aluminium wiring in the house](https://lightingelectrical.co.uk/problems/aluminium-wiring): Aluminium cable overheats at loose joints. We test it, write the electrical installation condition report, and price any copper replacement separately.
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Best Practice Guides](https://www.electricalsafetyfirst.org.uk/resources-for-electricians/best-practice-guides/)
- [NICEIC: Householder Guidance](https://niceic.com/householders/)

Updated 2026-11-16.