# Panel heater not working

> Panel heater no heat in Peterborough is traced from the wall switch and the fuse board until the failed control, fuse or element is named.

A cold panel heater has stopped making heat because its control, wall fuse or heater circuit has opened. Lighting Electrical in Peterborough finds that failed part on a test.

## Why is my panel heater not heating?

A panel heater stays cold when its control, its wall fuse or its circuit has opened. Other rooms stay live because that heater has its own switch.
- **The thermostat or timer is off:** The control on the front sets the temperature and the hours the panel should heat. A low setting or a timer that is off leaves the element cold while power is still at the wall switch.
- **The wall fuse has blown:** A fused connection unit is the switched fuse beside many fixed panel heaters. The switch being off, or the fuse inside it blowing, stops power before the panel. The rest of the house stays on.
- **The heater breaker has opened:** A breaker is the switch in the fuse board that guards one circuit. An RCBO is a breaker that also opens if current leaks to earth. When the heater breaker opens, every panel on that circuit goes cold.
- **The cut out or the element has failed:** A thermal cut out is a safety switch inside the heater that opens if the panel gets too hot. The element is the part that gives off the heat. Either fault leaves the wall switch live and the panel cold.
- **A loose joint at the heater:** Heat cycles loosen the terminals where the cable meets the panel or the wall switch. A loose joint stops the element or warms the switch. The fault stays at that joint until it is tested.

## What can I check on a cold panel heater?

You can read the heater controls, the wall switch and the fuse board with every cover left on. You do not open the heater or the board.
- **The controls on the front:** Turn the thermostat above the room temperature and set any timer to constant or boost. A panel that stays cold after that still has a supply fault or a fault inside the heater. Leave the casing screws in place.
- **The switch beside the heater:** The switch beside the panel should be on. If it is off, turn it on once. If it is hot, buzzing or smelling of burning, turn it off and leave the face screwed on.
- **The breaker with the cover shut:** Read the breaker named for heaters or for that room through the closed fuse board cover. A switch sitting down has opened. Reset it once only while the board is cool, quiet and free of a burning smell. If it drops again, leave it off.
- **One cold panel or several:** See which panels on that circuit are cold. One cold panel points to that heater or its wall switch. Every panel on the circuit cold points to the breaker. A portable panel can be tried in a socket you already know works, then unplugged.

## When should I book for a panel heater with no heat?

Book Now when the controls and one reset leave the panel cold, or when the wall switch or fuse board is hot, noisy or smelling of burning.
- **The panel stays cold after the checks:** The thermostat is high, the timer is on constant and the wall switch is on. The panel still gives no heat. The fuse, the element, the cut out or the cable needs a test.
- **The heater breaker drops again:** The heater breaker opens again after one reset with the wall switch off. The fault is still on the circuit. Another reset heats the breaker and the cable, so leave that breaker off.
- **The switch is hot or smells of burning:** A warm wall switch, a buzz or a burning smell means a joint is failing. Use the breaker handle on the front of the fuse board to switch that circuit off. Keep the heater casing and the board cover shut.

## What happens on a panel heater visit?

We start at the fuse board for the cold panel heater and tell you the failed part before a heater casing or a cable is opened.
- **Which panel went cold:** We ask which panel is cold, when it stopped, and whether the other panels still warm the room. We read the wall switch and the breaker with you. The covers stay on until a tester shows the circuit is dead.
- **Tests on the heater circuit:** We switch off the heater circuit. A dead test checks the cable while it has no power. The readings separate a blown fuse, a broken element, an open cut out, a loose joint and a tripped breaker. We tell you that part before we fit anything.
- **Only the failed heater or switch:** We open the wall switch or the heater that the readings have shown as failed. A sound panel stays shut. We check the terminals and the fuse in the connection unit on that run.
- **The repair and the certificate:** We fit the failed fuse, control, element or joint once you accept the repair. We then test the heater circuit a second time. A minor works certificate records any change to the fixed wiring and carries our NAPIT registration. The breaker stays off when that circuit should not be switched on.

## What does a cold panel heater visit cost?

The hourly charge for Electrical Fault Finding & Repair pays for the tests on this cold panel heater, the diagnosis spoken on the visit, and the repair once you accept that work. Replacing a wall fuse is a shorter job than tracing an open cable in the heater circuit. A part, a minor works certificate, or fuse board replacement moves the price.
- Fault finding & repair: from £75 an hour
- We fit a control, a fuse, a breaker or a piece of cable only when the readings show that part has failed.
- A new fuse board is a separate written price when the heater breaker or the board itself has failed.
- Emergency electrician work is a separate charge from the hourly fault finding.

## Questions about a cold panel heater

### Do you open the panel heater before testing?

No. We prove the circuit dead and test from the fuse board and the wall switch first. The casing comes off only when those readings show the fault is inside that heater. A sound panel stays shut.

### Can you repair the panel heater on the same visit?

We name the failed control, fuse, element or joint before any part is fitted. The repair of that part goes ahead on the visit once you accept it. A fuse board change waits for a separate price.

### Will a new fuse board make the panel heater heat?

A new fuse board brings the panel back only when the tests show the board or the heater breaker has failed. A failed element or a blown fuse at the wall switch still leaves the panel cold. We write a separate price for fuse board replacement when the tests show the board has failed.

### What paperwork do I get if you change the heater wiring?

A minor works certificate follows when we alter the fixed wiring or a protective device. The certificate lists the test results for that job and our NAPIT registration. A repair that stays inside the heater, with the house wiring left as we found it, is explained to you from the readings.

### What if several panel heaters are cold together?

Panels that share one breaker go cold together when that breaker or the cable feeding them opens. One cold panel, with the others still warm, points to that heater or its own wall switch. We test the circuit from the fuse board first, then the single panel.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [Energy Saving Trust: Heating Your Home](https://energysavingtrust.org.uk/advice/heating-your-home/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [HSE: Electrical Safety at Work](https://www.hse.gov.uk/electricity/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)