# Power goes off at the same time every day

> Power that cuts out at the same time every day in Peterborough is traced by Lighting Electrical to the timer, appliance or breaker that opens the circuit.

Power that drops at the same minute each day is a timed load or a timed switch opening a circuit. Lighting Electrical in Peterborough tests that circuit and names the device that opens it.

## Why does the power go off at the same time every day?

The power goes off at the same time because a clock switches a load on. That load opens a breaker, an RCD or the main switch. A breaker guards one circuit and the main switch guards the whole board. An RCD cuts the power when current leaks to earth. The clock is in a heater or an appliance.
- **Hot water and storage heater clocks:** An immersion is the electric heater in the hot water cylinder. A storage heater takes electricity on a timer and releases the heat later. The element switches on at the set hour. A worn element leaks current to earth and the RCD opens. Circuits that share that RCD go off together.
- **The off peak contactor:** Off peak power is a set block of hours on a cheaper tariff. A timeswitch is the clock that starts and ends that block. The timeswitch closes a contactor, a heavy switch that feeds the heaters. Worn contacts spark as they close. That spark trips the main switch or the RCD at the same minute each day.
- **Delay start on a washer, dryer or dishwasher:** Delay start tells the machine to begin at a chosen hour. A failing heater or pump leaks current to earth as the cycle begins. The RCD opens and every circuit on that RCD goes dead. The leak sits inside the closed machine. The next day brings the same trip at the same hour.
- **A load larger than the breaker rating:** A heater timer, an oven clock or a home charge point from Ohme, myenergi, Hypervolt or Andersen switches a large current on at a set hour. The current passes the breaker rating and the breaker opens. We measure the supply, the power coming into the house, against that load before any further price is written.
- **A loose connection under the daily load:** A loose screw in a socket, a joint or the fuse board warms when a regular load switches on. The heat opens the connection and the circuit goes dead. The opening follows the clock because that load starts at the same hour. The joint needs a test with the circuit switched off before the heat burns the cable.

## What can I check when the electricity cuts out at the same time?

You check the time of the cut, the switches on the closed fuse board, and one timed appliance at its own control. Every cover stays on. You touch no cable, no meter and no appliance interior.
- **The minute the power dies and what dies with it:** Write the clock time on two separate days. Note whether the whole house went dark or only the heating, the kitchen or one floor. A whole house cut while the neighbours stay lit points to the main switch or an RCD here. One dark floor points to a single breaker.
- **The switch positions with the cover still on:** Look at the switches with the fuse board cover still screwed on. The largest switch is the main switch and it feeds the whole board. An RCD is wider than a breaker and it feeds a group of circuits. Reset a cool, silent switch once. Leave it off if it opens again straight away.
- **One timed appliance off at its own control:** Choose the heater, machine or charger set for the hour the power dies. Turn it off at its own switch, its programmer or its wall isolator. A wall isolator is the switch fixed beside an immersion or a storage heater. Leave that appliance off for one day. Book Now if the cut still comes at that hour.
- **The next house and the street lights:** At the minute of the cut, look at the next house and at the street lights. Darkness only in this house means the fault is in this house's wiring. Darkness in the neighbouring houses means the electricity network has lost power. We test a fault in the house wiring. The network restores a cut that hits the street as well.

## When should I book if the power goes off at the same time?

Book Now if the cut returns at the same hour, if one reset will not hold, or if the fuse board is hot, buzzing or smelling of burning.
- **The cut returns with the timer already off:** The obvious appliance is off and the power still dies at that minute. Another timer, the contactor or a different circuit is still opening. Extra resets heat the device that keeps tripping. Book Now and leave the switch that drops in the off position.
- **The main switch or the RCD drops again:** You reset a cool, quiet board once and the switch falls straight away. Current is still leaking to earth, or a short is still present. A short is live conductors touching. Further resets heat the cables. Leave the switch that falls in the off position.
- **Heat, a buzz or a burning smell:** A warm fuse board cover, a buzz or a burning smell means a joint is arcing. Arcing is a spark across a loose connection. Turn the board off with the front toggle of the main switch. Keep your hands off the cover screws and off every cable.

## What happens on the visit for a power cut at the same time each day?

We test the circuit that opens at the hour the power dies. We name the failed timer, contactor, connection or breaker before fitting anything.
- **The time, the rooms and the closed board:** We ask the hour the power dies and which rooms go dark with it. We ask which heater, machine or charger is set for that hour. The fuse board cover stays screwed on while we read every switch. We note the switch that is sitting off.
- **Meter readings with the circuit off:** We switch off the circuit that opens. Our meter reads the cable in that off state, which is a dead test. One reading shows current leaking to earth. Another shows a broken conductor. The readings separate a worn element, a worn contactor, a damaged cable and a breaker that has not failed.
- **The failed part, the earth path and the load:** We name the failed part before a tool touches it. We test the earth path that carries stray current back to the supply. We test the bonding conductors that tie the metal pipes to that earth. We compare the incoming supply, the power arriving at the house, with the timed load. The next price follows those readings.
- **The repair and the minor works certificate:** You say yes to the repair and we fit the new timer, contactor, connection, breaker or cable. We test the circuit once the new part is in. A minor works certificate records that alteration and the test results. Our NAPIT registration is on that certificate. The breaker stays off if the circuit must not be put back on.

## What does a timed power cut visit cost?

Electrical Fault Finding & Repair is charged by the hour when the power drops at a set time. That hour covers tests on the circuit that opens, a spoken diagnosis, and the repair once you say yes. The price changes with a longer test, a fitted part, or a certificate for the altered circuit. Fuse board replacement and emergency electrician attendance are priced as their own jobs.
- Fault finding & repair: from £75 an hour
- Testing a timeswitch and a contactor takes longer than naming one appliance on a plug timer.
- A Hager, Wylex or Contactum breaker is fitted only when that breaker has failed the test.
- Fuse board replacement and an emergency electrician call each carry a separate written price.

## Questions on a power cut at the same time each day

### Do you need to be at the property at the minute the power cuts out?

No. We test the circuit switched off, so the visit does not depend on the clock reaching that minute. The meter readings separate a leaking element, a worn contactor, a damaged cable and a breaker.

### Will a new fuse board stop the power going off at the same time?

Only when the tests show the board has failed does a new fuse board stop the cut. A failed timer, contactor or connection leaves the present board where it is. Fuse board replacement is then a separate job with its own written price.

### Does this visit include a new immersion element?

No. A leaking immersion element is named by the tests, and the new element is Immersion heater repair with its own price. A failed connection, breaker or cable is repaired on this visit once you say yes.

### What certificate do you write after the repair?

We write a minor works certificate when the repair alters the circuit. The certificate records the tests we took and carries our NAPIT registration. An Electrical Installation Condition Report, called an EICR, is a separate inspection of every circuit and is booked as its own visit.

### Will you repair my charger on this visit if it starts at that minute?

No. The charge point itself is EV charger installation with its own price. A failed house breaker, joint or cable is repaired on Electrical Fault Finding & Repair once you say yes.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [IET: BS 7671 Guidance Publications](https://electrical.theiet.org/guidance-and-codes-of-practice/publications-by-category/bs-7671-and-guidance/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)