# Power surge damage to electrics

> Power surge damage in Peterborough. We test the fuse board, the circuits and any dead appliance, then name the part the spike has failed.

A power surge damages electrics by forcing a high voltage through appliances and the fuse board. Lighting Electrical traces that damage in Peterborough and names each failed part.

## Why does a power surge damage electrics?

A surge is a brief voltage spike above the normal supply, and it pushes excess current through appliances, joints and protective devices. The cable, the fuse board or a plugged in appliance can fail while other circuits stay on.
- **A spike from the supply:** Lightning or a fault on the network lifts the voltage for a fraction of a second. That spike arrives at the fuse board and passes into every circuit that is switched on.
- **A large motor switching off:** A pump, a compressor or another motor can kick voltage back onto its circuit as it starts or stops. Electronics on that circuit see the spike even when the motor still runs.
- **A missing or spent surge device:** A surge protection device, called an SPD, sits in the fuse board and clamps a high voltage. An older board may have no SPD. A device that has already clamped a surge shows a failed flag and does not clamp the next one.
- **A loose terminal that overheats:** The spike heats a loose terminal in a socket, a switch or the fuse board. The joint chars, the breaker opens, and the circuit stays dead after the supply voltage has settled.
- **Electronics that cannot take the spike:** Chargers, alarm panels, boiler controls and televisions use small electronic parts. Those parts fail at a voltage the house cable can still carry, so the appliance dies while the circuit looks intact.

## What can I check safely after a power surge?

You can look at the fuse board, unplug damaged appliances and note what died. Appliance cases stay shut, and the fuse board cover stays on.
- **Switches seen through the cover:** A breaker or an RCD sitting down has opened. An RCD is the safety switch that trips when current leaks to earth. Reset it once only if the board is cool, quiet and free of any burning smell.
- **Plugs with heat or brown marks:** Unplug any appliance that is dead, hot or smelling of burnt plastic. Brown marks on the pins mean the plug has been overheating. Leave the appliance case closed.
- **One appliance or several rooms:** Write down whether one appliance died or several rooms lost power together. Several rooms point to the fuse board or the incoming supply. One appliance points to that appliance or the socket it used.
- **A flag on the surge device:** Some fuse boards show a small window on the SPD. A changed colour or a failed mark means the device has already operated. You do not remove the cover to hunt for that window.

## When should I book after surge damage?

Book Now if a breaker will not hold, if you smell burning, or if several appliances failed at the same moment.
- **The switch opens again:** Damaged appliances are unplugged and the breaker still drops. The fault remains in the fixed wiring or in a protective device. Leave that breaker off.
- **Heat, smell or scorch marks:** A burning smell, a warm faceplate or brown marks on a plug mean a joint is failing. Switch that circuit off with the breaker handle. Keep your hands off socket screws and the board cover.
- **Many appliances dead together:** Two or more appliances failing in the same moment means the spike reached the fuse board. The surge device and the circuits need a test before those appliances are plugged in again.
- **The surge device shows failed:** A failed mark on the SPD means the next spike has nothing to clamp it. The board and the device need a test. Leave the cover screwed on.

## What happens on a surge damage visit?

On a visit in Peterborough we isolate the damaged circuits, test them, and name the failed part before any fitting is changed.
- **Which appliances and breakers failed:** We ask what died, whether a storm or a trip came first, and which breakers are down. The cover stays shut until a tester shows the circuit is dead.
- **Measurements on the dead circuits:** We switch off the damaged circuits and test them while they are dead. An insulation test looks for leaking current between the conductors. A continuity test checks that the copper still joins end to end.
- **The SPD and the device that opened:** We check whether an SPD is fitted and whether its flag shows it has operated. We then test the RCD or RCBO that opened. An RCBO combines a breaker and an RCD in one device for a single circuit.
- **The repair and the certificate:** We name the failed part and change it only after you accept the repair. We test the circuit again. Where the circuit changes, a minor works certificate records the tests under our NAPIT registration. Before a further price we check earthing, the fault path back to the board, and bonding, the link from metal pipes to that earth, plus whether the supply can carry another load.

## What does a surge damage visit cost?

The price follows the hours spent on Electrical Fault Finding & Repair. Those hours cover the tests after the surge, the diagnosis we give you, and the start of the repair once you accept it. A longer test on several circuits, a replacement SPD or breaker, or a minor works certificate changes the price. Fuse board replacement is priced on its own when the tests show the board has failed. Emergency electrician attendance is a separate job.
- Fault finding & repair: from £75 an hour
- One dead appliance needs less testing than a spike that has opened several circuits.
- An SPD for a Hager, Wylex or Contactum board is fitted only when the test shows the device has failed.
- A new fuse board carries its own price when the surge has damaged the board.

## Questions about power surge damage

### Can one surge damage several appliances?

Yes. A single spike can reach every appliance that was plugged in and switched on. We test the fuse board and the circuits as well, because a dead appliance can sit next to a damaged protective device.

### Should I reset the breaker more than once?

One reset is reasonable after damaged appliances are unplugged, and only while the fuse board stays cool and quiet. If the breaker opens again, leave it off. Further resets heat a joint the spike has already damaged.

### Will a new fuse board undo the surge damage?

Only if the tests show the board or its SPD has failed. A sound board stays in place and the failed socket, joint or appliance is repaired instead. Any board change is priced on its own after those tests.

### What paperwork follows a surge repair?

Where we alter a circuit, a minor works certificate lists the tests for that alteration and our NAPIT registration. If we only isolate a dangerous circuit and change nothing, you still get the readings and the named fault. An Electrical Installation Condition Report, an EICR, inspects the whole installation and is arranged as its own job.

### What if only one appliance is burnt?

The appliance may be the only failed part. We test the circuit with that appliance unplugged. If the wiring and the protective devices pass, the circuit goes back on and the appliance stays unplugged.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [HSE: Electrical Safety at Work](https://www.hse.gov.uk/electricity/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)