# Pull cord light switch not working

> Pull cord light switch not working in Peterborough. We test the ceiling switch and lighting circuit and fit a new cord switch if that switch has failed.

A pull cord that does nothing means the ceiling switch, the lamp or the lighting circuit has failed. Lighting Electrical tests that ceiling switch with the lighting circuit isolated.

## Why does a pull cord light switch stop working?

A pull cord stops working when the ceiling switch, the lamp or the lighting breaker fails. The cord itself is only the handle for a switch fixed to the ceiling.
- **The toggle inside the ceiling switch:** Each pull turns a small toggle that snaps the contacts open or closed. When the toggle wears out, the cord still moves but the contacts never meet. The lamp and the breaker stay sound while the toggle has failed.
- **The cord has come off the toggle:** The cord is held inside the switch by a knot or a clamp. A sharp tug pulls it free of the toggle. The string still hangs down, yet it no longer turns the switch on or off.
- **The lamp or the lamp holder:** A spent lamp gives the same darkness as a dead switch. The lamp holder is the part that grips the lamp cap. Heat loosens those contacts, so the cord still clicks and the lamp stays dark.
- **The lighting breaker has opened:** A breaker is the switch in the fuse board that cuts power to one circuit. The pull cord uses that breaker with the other lights on the same cable. When the breaker opens, all of those lights go off together.
- **Damp on a bathroom ceiling switch:** Steam from a shower can sit on the ceiling switch. Water across the contacts leaks current to earth, the safety path back to the fuse board. An RCD, the safety switch that detects that leak, then cuts the circuit.

## What can you check on a pull cord safely?

You can change the lamp, listen to the cord and read the breaker through the closed fuse board cover. The ceiling switch stays shut.
- **A lamp that already works:** If the shade lifts off by hand, fit a lamp that lights in another room. Light from that lamp means the old lamp failed. Darkness means the ceiling switch or the circuit is at fault.
- **A click when the cord is pulled:** Pull the cord once. A clear click means the toggle still moves. No click, or a cord that feels slack, means the cord has left the toggle or the toggle has broken. Stop pulling a slack cord.
- **Lights that use the same circuit:** Switch on another light in the same room or on the landing. If those lights are dark too, the lighting breaker has opened. If they come on, the fault is this ceiling switch or this lamp.
- **The breaker behind a closed cover:** Find the breaker marked for lights and read it with the cover still on. Reset it once only when the board is cold, silent and has no smell of burning. If it opens as soon as the cord is pulled, leave the breaker down.

## When should you book for a dead pull cord?

Book Now when a good lamp stays dark, the cord will not click, or the ceiling looks scorched. A single spent lamp in a cool fitting is a lamp change.
- **The cord does not click:** The toggle or the cord link has failed. Another hard pull can leave the cord in your hand with the contacts half made. Book Now and leave the cord still.
- **A working lamp stays dark:** The lamp is sound and the other lights on that circuit still come on. The fault sits in this ceiling switch or in the cable at that point. That switch needs a test with the circuit off.
- **Heat, brown marks or a burning smell:** A warm ceiling, brown marks around the switch or a burning smell means a loose terminal is heating. Leave the lighting breaker down. Keep your hands off the switch screws.
- **The breaker opens when the cord is pulled:** The switch or the cable is shorting as the contacts close. Another reset heats the same joint. Leave that breaker down and Book Now.

## What happens on a visit for a dead pull cord?

We isolate the lighting circuit, test the ceiling switch and fit a new pull cord switch only when that switch has failed.
- **Which cord failed:** We ask which room, whether the cord still clicks, and which other lights still come on. We look at the lighting breaker with you. Every screw stays in until our tester reads that circuit as dead.
- **Tests on the lighting circuit:** With the lighting breaker off, we test whether the cable to the ceiling switch is broken, shorted or leaking to earth. The readings separate a worn toggle, a failed lamp holder and a damaged cable.
- **The ceiling switch comes apart:** We open only the ceiling switch that failed the test. A sound switch in the next room stays closed. We check the cord clamp, the toggle and the terminals before anything new is fitted.
- **A new cord switch and a retest:** Where the switch has failed, we fit a pull cord switch on the same lighting cable. We put the circuit back on and test the light. Where that circuit was altered, we write a minor works certificate with our NAPIT registration.

## What does a pull cord repair cost?

You pay for the time to isolate the lighting circuit and test the ceiling switch, the lamp and the cable at that point. The spoken test result is part of that price. A new pull cord switch is added when the test shows the old one has failed. A new cable, a lamp holder, a minor works certificate or a separate fuse board job changes the price.
- Downlight installation (per fitting): from £65
- An MK Electric or Varilight ceiling switch is fitted only when the test shows the old switch has failed.
- A longer cable run or a burnt lamp holder is extra work on the same visit.
- When the lighting breaker or the board has failed, fuse board replacement is a different job with its own price.

## Questions about pull cord light switches

### Can I change a bathroom pull cord for a wall switch?

Only where the new switch can sit outside the wet area around the bath or shower. Inside that area the light stays on a ceiling pull cord, so wet hands meet the cord and not a live switch. We say which of the two fits the room after we see it.

### Do I get paperwork when the pull cord switch is replaced?

A minor works certificate records the ceiling switch we change and the tests on that lighting circuit. It carries our NAPIT registration. A house wide Electrical Installation Condition Report is a different visit from this switch change.

### What if the fan cord works and the light cord does not?

Some bathrooms have one cord for the light and a second cord for the fan. A working fan with a dark lamp means the light switch or the lamp has failed. We test that light cord on its own and leave the fan cord as it is.

### Will a new fuse board make the pull cord work?

A new board brings this light back only if the lighting breaker itself has failed. A worn toggle still leaves the lamp off, so the ceiling switch is still changed. Fuse board replacement has its own price after the lighting circuit is tested.

### Can you fit the pull cord switch I have bought?

Yes, when it is a ceiling switch made for a lighting circuit and it suits a bathroom light in the wet area. We check the terminals and the cord clamp before it goes on the ceiling. A switch that is wrong for the room stays unused.

## Related problems
- [Dimmer switch lights flicker](https://lightingelectrical.co.uk/problems/dimmer-lights-flickering): Flicker on a dimmer comes from lamps that do not suit the dimmer, or from a loose joint on the lighting circuit.
- [Dimmer switch not working](https://lightingelectrical.co.uk/problems/dimmer-switch-not-working): A dimmer stops working when its module fails, the lamps cannot dim, or the lighting circuit opens.
- [Lights flickering after a new fitting](https://lightingelectrical.co.uk/problems/lights-flickering-after-new-fitting): A new fitting flickers when the lamp, the dimmer or a loose joint does not suit the lighting circuit.
- [Why is my ceiling light buzzing](https://lightingelectrical.co.uk/problems/light-fitting-buzzing): A buzzing ceiling light is a loose joint, a failing lamp or a dimmer that does not suit the lamp.
- [Why is my dimmer switch humming?](https://lightingelectrical.co.uk/problems/dimmer-switch-buzzing): Hum comes from lamps that do not suit the dimmer, or from a loose joint in the switch.
- [Wires hanging from the ceiling](https://lightingelectrical.co.uk/problems/wires-hanging-from-ceiling): Hanging ceiling wires are cable ends left outside a rose, and the lighting circuit is isolated before they are refitted.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)