title: "RCBO keeps tripping | 4.7 Star · NAPIT approved · From £60"
description: "RCBO tripping in Peterborough means one circuit has opened. Lighting Electrical tests that circuit and tells you what the readings show."
canonical: "https://lightingelectrical.co.uk/problems/rcbo-keeps-tripping"
---

# RCBO keeps tripping

> RCBO tripping in Peterborough means one circuit has opened. Lighting Electrical tests that circuit and tells you what the readings show.

An RCBO that keeps opening cuts power to one circuit after a leak to earth or an overload. Lighting Electrical in Peterborough measures that circuit and reports the failed part.

## Why does an RCBO keep tripping?

An RCBO keeps tripping because that one circuit is leaking current to earth or drawing more current than the device allows. Other circuits on their own devices stay on.
- **Current leaking to earth on that circuit:** An RCBO combines a breaker and an RCD for one circuit. An RCD switches off when current leaks to earth, the safety path that carries a fault away from you. A damaged cable or a wet joint on that circuit opens the RCBO.
- **Too much load for that RCBO:** The breaker part of the RCBO opens when the circuit draws more current than the device rating. Running a kettle and a heater together on that circuit can open it. The RCBO on the next circuit stays up.
- **An appliance leaking on the circuit:** A fridge, a washer or a heater can leak current inside its own case. The RCBO for the socket it uses then opens. With that appliance unplugged, a sound circuit lets the RCBO stay up.
- **Water on an outside point or a bathroom fitting:** Rain in an outside socket, or steam across a bathroom fitting, lets current leak to earth. The RCBO that guards that circuit opens. A separate RCBO for another room stays up.
- **A failed RCBO in the fuse board:** The RCBO can open because its own contacts or test mechanism have failed, while the circuit tests sound. We fit a replacement from Hager, Wylex, Contactum, BG Electrical or MK Electric only after those tests.

## What can I check safely before booking?

You can read the fuse board with the cover closed, pull plugs, and reset the RCBO once. Every cover, cable and appliance case stays shut.
- **Which RCBO is sitting down:** The fuse board cover stays closed. The RCBO sitting down is the circuit that opened, and the writing beside it names that circuit. Every RCBO still sitting up is feeding its own circuit.
- **Unplug the circuit and reset once:** Pull every portable plug on that circuit, including extension leads. Reset the RCBO once while the board is cool, silent and free of a burning smell. If it opens straight away, leave it off.
- **Try a lamp you already trust:** Plug a lamp that already lights in another room into a socket on the tripped circuit. If the lamp stays off, that circuit still has no power. If it lights after the reset, the appliance you removed was the cause.
- **Heat, a buzz or brown marks:** A warm plate, a buzz or brown marks around the pins means a joint is overheating. Stop using that point. Switch the RCBO off by its handle and leave every screw in place.

## When should I book for a tripping RCBO?

Book Now when a single reset will not hold, or when a fitting is hot, wet or smelling of burning.
- **The RCBO opens again at once:** The plugs are out and the RCBO still opens immediately. The fault is in the cable, a fitting or the device itself. Leave it off, because another reset heats the terminals.
- **Heat, noise or a burning smell:** A warm socket, a buzz or a burning smell means the joint is arcing. Arcing is a spark jumping a loose connection, and it chars the cable behind the face. Leave that RCBO switched off.
- **Water has reached the circuit:** Rain in an outside socket, or flood water near a fitting, sends current to earth. Leave the RCBO off. Keep your hands off the wet plastic and off the fuse board cover.

## What happens on a visit for a tripping RCBO?

We start testing at the fuse board and follow the circuit the RCBO protects. We say what has failed, then wait until you accept a repair.
- **Which circuit the RCBO opened:** We ask when the trip started and which sockets or lights went off. We read the writing beside the RCBO with you, and the cover stays shut. No screw comes out until our tester shows that circuit is dead.
- **Readings on the isolated circuit:** We switch that circuit off at the RCBO. Continuity testing shows whether the copper still connects along the run. Insulation testing shows whether current is leaking between the conductors. Those readings separate the cable, the fitting, the appliance and the RCBO.
- **Earthing and supply before a further price:** We tell you the failed part before we change it. We check the earthing, which is the path fault current uses, and the bonding that joins metal pipes to the earth bar. We also check the supply can carry the load before any further price is written.
- **The repair and the certificate:** After you accept the repair, we put right the failed joint, fitting, cable or RCBO. We test the circuit again. A minor works certificate follows when the circuit was altered, and it carries our NAPIT registration. The RCBO stays off if the circuit cannot be left live.

## What does an RCBO fault visit cost?

We charge Electrical Fault Finding & Repair by the hour. That price covers the tests on the tripped circuit, the diagnosis we give you, and the start of the repair once you accept it. More time on a long circuit, a replacement part, or a minor works certificate changes the price. Emergency electrician work is charged separately.
- Fault finding & repair: from £75 an hour
- Tracing a leak along the whole circuit takes longer than showing that one unplugged appliance caused the trip.
- We fit a replacement RCBO, socket or length of cable only after the tests show that part has failed.
- When the tests show the board itself has failed, we price fuse board replacement as a separate job.

## Questions about an RCBO that keeps tripping

### Will the rest of my house stay on?

Yes. We switch off only the circuit that the RCBO guards, and every other circuit stays on. That circuit is put back on after the repair, and it stays off if it cannot be left live.

### Will you change the RCBO before you find the fault?

No. We test first and name the failed cable, fitting, appliance or RCBO. The repair starts only after you accept it. An RCBO that tests sound stays in the fuse board.

### What paperwork do I get after the repair?

Where the repair alters the circuit, you get a minor works certificate for that job. It lists the test results and our NAPIT registration. An EICR is a separate inspection of the whole installation.

### Will a new fuse board stop the RCBO tripping?

Only when the tests show the RCBO or the board has failed. A damaged cable or a leaking appliance still opens a new device. Any fuse board replacement is priced on its own after the tests.

### What if my RCBO only trips now and then?

We still test that circuit, because a trip that comes and goes leaves a measurable trace at the board or on the cable. We tell you what the readings show on the day. If the fault does not appear while we are there, we tell you what still needs watching.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [IET: BS 7671 Guidance Publications](https://electrical.theiet.org/guidance-and-codes-of-practice/publications-by-category/bs-7671-and-guidance/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)