# RCD test button not working

> RCD test button not working in Peterborough: Lighting Electrical tests the safety switch on the fuse board and names the failed device before any repair.

If the RCD test button does nothing, the safety switch has not shown it will cut a leak to earth. Lighting Electrical tests that device in Peterborough.

## Why does the RCD test button do nothing?

The button does nothing when the RCD is off, has lost its supply, or the mechanism inside will not open. An RCD is the safety switch that should cut power if current leaks to earth.
- **The RCD lever is already down:** The test button works only while the RCD is switched on. A lever that is already down has opened the device. The button cannot trip it a second time. A fault on a circuit it covers can leave it down.
- **The main switch is off:** The main switch feeds the devices in the fuse board. With that switch down, the test circuit inside the RCD has no power. The button then does nothing even when the RCD itself is sound.
- **The mechanism inside the RCD has stuck:** The button puts a small test leak through the device. A sound RCD opens at once. A stuck mechanism stays up. The RCD is then not showing it can clear a real leak to earth.
- **The test circuit inside has failed:** The button and a small resistor sit inside the RCD. An open path there means the press creates no test leak. Circuits on that RCD can stay live with no working test.
- **The device is an RCBO:** An RCBO guards one circuit as both a breaker and an RCD. A breaker is the switch that opens on too much current. The RCBO button should still drop that one device. If it does nothing, that circuit has lost its leak test.

## What can I check with the fuse board cover on?

You can read the switches and press the test button once while the fuse board cover stays on. The screws stay in and the cables stay untouched.
- **The RCD lever:** Read the lever through the closed cover. Up means the RCD is on and the button can act. Down means it has opened. Lift it once only if the board is cool, quiet and free of a burning smell. If it falls at once, leave it down.
- **The main switch:** The main switch is the widest switch on the fuse board. Read it through the closed cover. The test button needs it up. Leave it where it is when the rest of the house still has power.
- **One press of the button marked T:** The notice on the fuse board asks for this press every three months. Press the button once. A working RCD drops its lever and the circuits on it go off. Put the lever back up to restore them. If the lever does not move, stop.
- **Heat, a buzz or a burning smell:** A warm cover, a buzz or a smell of hot plastic means you stop. Do not press the button again. Leave the cover screws where they are.

## When should I book for a failed RCD test button?

Book Now when one press does nothing and the RCD lever and the main switch are both up. Heat, noise or a burning smell at the fuse board needs a visit as well.
- **The button does nothing:** The RCD lever and the main switch are up, and one press leaves the lever up. The device has not shown it will open. Book Now so the RCD can be tested.
- **The lever will not stay up:** The RCD opens again as soon as you reset it. A fault remains on a circuit it covers, or the device itself is failing. Leave the lever down.
- **The fuse board is hot or smelling:** Heat, a buzz or a burning smell at the cover means a joint inside is failing. Use no tool on the cover. Book Now and keep the cover shut.

## What happens on a visit for a dead RCD test button?

We test the RCD and name the failed part before any device is changed. The repair starts when you say yes to the work.
- **What the button did:** We ask whether the lever moved and which rooms went off. We ask whether the board is warm or smelling. We read the main switch and the RCD with you. The cover stays on until a tester shows it is dead and safe to open.
- **Tests on the device and its circuits:** We switch off the RCD we are testing. A trip test checks whether the device opens on a set test current. An insulation test then measures leaking current between the wires on its circuits. The two readings separate a bad device from a bad circuit.
- **Which part has failed:** We tell you whether the RCD, an RCBO or a circuit on it has failed. A sound device stays in the fuse board. We measure the earth path back to the board. We measure the links on the metal pipes. Further work is priced only after those readings and after we know the supply can feed the load.
- **The repair and the certificate:** We fit the failed RCD or RCBO when you say yes. We test the device again after the work. Where the circuit changed, we issue a minor works certificate as a NAPIT registered contractor. We leave the device off when it is unsafe to switch it on.

## What does an RCD test visit cost?

Electrical Fault Finding & Repair is charged for the time spent on the test. The price covers the readings on the RCD, the diagnosis we give you, and the start of the repair when you say yes. A replacement device, a minor works certificate, or a fuse board replacement changes the price.
- Fault finding & repair: from £75 an hour
- A Hager, Wylex, Contactum, BG Electrical or MK Electric device is fitted only when the tests show it has failed.
- Fuse board replacement is written as its own job when the tests show the board has failed.
- Emergency electrician is charged as its own job, separate from Electrical Fault Finding & Repair.

## Questions about an RCD test button

### Will you change the RCD before you test it?

No. We test the device and name the failed RCD, RCBO or connection first. The repair of that part starts when you say yes. A sound device stays in the fuse board.

### Does a dead test button mean I need a new fuse board?

Only when the tests show the board has failed. A single RCD or RCBO can be changed on its own when that device is the failed part. Fuse board replacement is priced as its own job.

### What paperwork comes after the RCD is repaired?

You get a minor works certificate when we change the device or alter the circuit. It records the tests for that work and our NAPIT registration. An Electrical Installation Condition Report, which we call an EICR, is a different inspection of the whole installation.

### Should I leave the RCD on if the button does nothing?

No. The device has not shown it will cut a leak to earth. Switch that RCD off with its lever and leave the cover on. Other circuits that are still healthy can stay on.

### What if the button trips the RCD but it will not reset?

The button has worked. A fault on one of its circuits is holding the lever open. We test those circuits and name the failed cable, accessory or appliance. The RCD stays off until you say yes to the repair.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [Electrical Safety First: Your questions answered (Can an RCD fail?)](https://www.electricalsafetyfirst.org.uk/safety-advice/your-questions-answered/)
- [IET: BS 7671 FAQs, Consumer units and protective devices](https://electrical.theiet.org/bs-7671/faqs/consumer-units-and-protective-devices-faqs/)
- [Electrical Safety First: Advice for older and vulnerable people (finding the RCD Test button)](https://www.electricalsafetyfirst.org.uk/safety-advice/home-and-people/older-and-vulnerable-people/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)