An RCD trips at night because current leaves the live and fails to return once a night circuit switches on. Lighting Electrical, based in Peterborough, measures that leak and names the circuit before changing a part.

## Why does an RCD trip at night?

An RCD trips at night because a leak starts on a circuit that switches on after dark. The RCD compares current leaving on the live with current returning on the neutral. It opens when the two figures no longer match.
- **Immersion heater on a night timer:** The immersion timer switches the cylinder element on after dark. A crack in the element lets current pass into the water. The RCD opens because that current does not return on the neutral.
- **Fridge or freezer motor starting:** The fridge compressor starts and stops all night. Worn windings leak current to the metal case when the compressor starts. A damp defrost heater leaks when it switches on later in the night.
- **Outside light switching on at dusk:** A wall lantern, or a PIR sensor light that switches on when it sees movement, comes on at dusk. Rainwater in the lamp holder leaks current to the metal body. The RCD opens with that light and stays on through dry days.
- **EV charger on an overnight schedule:** A tethered EV charger begins a scheduled charge after dark. A wet plug or a damaged lead leaks current while the car charges. The RCD opens during that charge. Daytime socket use leaves the charger idle, so the RCD stays on.
- **One RCD feeding several circuits:** Where one RCD feeds the sockets, the lights and the cooker, those circuits share a single trip point. The immersion or the charger adds enough further leak to pass that point. The RCD opens and no socket looks scorched.

## What can I check safely when the RCD trips at night?

You can note the time, read the closed fuse board and unplug appliances. The fuse board is the box of switches beside the meter. Leave every cover screwed down. Do not open an appliance or touch gas, refrigerant or the fixed wiring.
- **The time and what had just started:** Write down the time the RCD opened and the load that had just started. Note the immersion switch, the fridge, any outside light, and the charger lamp. Bring that note to the visit.
- **The switches behind the closed cover:** Look at the fuse board with the cover shut. The RCD is the wider switch with a button marked T. An RCBO is a narrower switch that guards one circuit against too much current and against a leak. Reset the open switch once only when the plastic is cool, the board is silent, and you smell nothing burning.
- **Plugs out and the immersion isolator off:** Unplug the fridge, the washing machine and the charger lead. Switch the immersion off at the isolator beside the cylinder. Reset the RCD once, then plug each appliance back until the RCD opens again.
- **Outside lights left closed:** Look at the wall lantern from the ground. Water on the glass, or a PIR light that switches on as you walk up, points to that fitting. Leave the wall switch off. Do not open the lantern and do not open the fuse board.

## When should I book for an RCD that trips at night?

Book Now if the RCD will not hold after one reset, or if it opens at the same hour each night. Those two patterns mean a leak is still on the circuit.
- **The RCD drops again after one reset:** The night appliances are unplugged, the immersion isolator is off, and the RCD still opens at once. The leak sits in the wiring, a fitting, or the RCD. Leave that RCD off and Book Now.
- **The trip comes at the same hour:** The RCD opens as the immersion timer, the EV charge or the delayed washing machine starts. That starting load is the circuit we measure on the visit. Book Now.
- **A warm board, a buzz or scorching:** Heat on the fuse board, a buzzing sound, or a sharp scorch smell means a terminal is sparking. Sparking burns the plastic around the screw. Use the RCD toggle to switch it off and stay away from the cover.
- **Rain and the outside lights:** The RCD opens on wet nights as the outside lantern lights, and it stays on during dry nights. Water is crossing the lamp holder to the metal body. Leave that lantern switched off and Book Now.

## What happens on the visit when the RCD trips at night?

The visit names the part leaking at night before anything is changed. We repair the wiring, the fitting or the RCD once you say yes.
- **The time of the trip and the open switch:** We ask what time the RCD opened and which load had just started. We look at the fuse board with the cover still shut and record the RCD or RCBO that has dropped. No cover screw is undone until a tester reads zero volts.
- **Measurements with the night circuit off:** We switch off the circuit that was on at the time of the trip. An insulation test applies a voltage to the disconnected conductors to reveal current passing between them. A ramp test feeds a rising current through the RCD until it opens, showing the trip current of the device.
- **Earthing and bonding before a further price:** We tell you which part leaked before we change anything. We check the earthing, the copper path that carries fault current back to the supply. We check the bonding, the green and yellow conductor that ties pipework to the installation earth. We check the supply can carry the load before we price any further work.
- **The repair and the certificate:** We repair the failed joint, cable, fitting or RCD after you say yes. We unplug a leaking appliance without opening it. We run the tests again after the repair. We complete a Minor works certificate under NAPIT. The certificate is the written record of the alteration and the test results. We leave the RCD off if the leak is still present.

## What does a night RCD trip visit cost?

We charge Electrical Fault Finding & Repair by the hour when an RCD trips at night. The hour covers the board tests, the diagnosis we talk through with you, and the repair of the named fault once you say yes. A longer test, a replacement part, paperwork, or a different job changes that price.
- Fault finding & repair: from £75 an hour
- The hourly price covers the tests and the diagnosis. We add a part only when the tests show that part has failed.
- We price Fuse board replacement, Immersion heater repair and EV charger installation as separate jobs when the tests point to that work.
- We add a Minor works certificate when the repair alters a circuit. We price an EICR, the Electrical Installation Condition Report, as its own inspection of the whole installation.

## Questions about an RCD tripping at night

### Will you change the RCD before you know why it trips at night?

No, the tests come first, and we name the leaking appliance, fitting, cable or device before anything is changed. An RCD by Hager, Wylex, Contactum or BG Electrical goes in only after the tests show the device has failed. That repair sits inside the fault finding visit once you say yes.

### Should I keep resetting the RCD through the night?

One reset is enough when the plastic is cool and the board is silent. A further reset that drops straight away heats the RCD and the cable. Leave the RCD off and Book Now.

### Will a new fuse board stop the night trips?

A new fuse board stops these night trips only where test shows RCD failure. A cracked immersion element or a wet lantern still opens the RCD on a new board. We price Fuse board replacement separately once testing is finished.

### What paperwork do I get after the repair?

Where the repair alters a fitting, a cable or the RCD, we complete a Minor works certificate. The certificate lists the test results for that circuit and shows our NAPIT registration. An EICR, the Electrical Installation Condition Report, is a separate inspection of the whole installation.

### Can my overnight EV charge trip the house RCD?

A wet plug or a damaged tethered lead on a charger that starts after dark leaks during the charge and opens the house RCD. We test the charger circuit on its own, apart from the sockets and the lights. If the charge point has failed, EV charger installation is quoted as its own job.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [NICEIC: Householder Guidance](https://niceic.com/householders/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)