# PIR light not coming on

> PIR light not coming on in Peterborough means the sensor, lamp or lighting circuit has failed. Lighting Electrical tests the fitting and names the part.

A dark PIR light means the sensor, the lamp or the lighting circuit has failed, and Lighting Electrical tests that fitting in Peterborough.

## Why is my PIR light not coming on?

A PIR light stays off when the sensor thinks it is daytime, the lamp has failed, or the lighting circuit has lost power. PIR means passive infrared, a sensor that looks for body heat.
- **The daylight setting is holding it off:** The daylight control is marked lux on many lanterns. Lux sets how dark the sky must be before the lamp is allowed to switch. Set for night, the lantern stays dark in the day while people walk past. The sensor is doing what it was set to do.
- **The lamp or the LED has failed:** A click from the sensor with a dark lamp means the bulb, the LED chips or the driver has failed. The driver is the small unit that powers the LED. The lighting circuit is still live at the fitting.
- **Dirt or a cobweb over the sensor:** The sensor window sits on the lantern face. Paint, dust or a cobweb blocks the view of body heat, so the lamp never switches on. A photocell under the same dirt reads the sky as bright and holds the lamp off.
- **The lighting circuit has opened:** A breaker is the switch in the fuse board that guards one circuit. If that breaker has opened, every light on it goes dark, including the sensor lantern. An RCD, the switch that opens when current leaks to earth, does the same when it covers that circuit.
- **The sensor module has failed:** The PIR module is the part that decides when to switch. Water behind an outdoor lantern, or a burnt joint at the lamp, leaves the module dead. The rest of the lighting circuit stays on.

## What can I check on a sensor light safely?

You can use the wall switch, read the fuse board through its cover, and wipe the outside of the sensor. Leave the lantern screws in and keep off the cables.
- **The wall switch that feeds the lantern:** Many sensor lights still have a normal switch indoors. Leave that switch on for automatic operation. If nothing happens, turn it off, wait a few seconds, and turn it on again. Do not take the switch apart.
- **The lighting breaker with the cover shut:** Look through the fuse board cover. A lighting breaker sitting down means that circuit is off. One reset is reasonable if the board is cool, quiet and has no burning smell. If it opens again, leave it down.
- **The sensor window on the outside:** Wipe the plastic sensor window with a dry cloth. Clear cobwebs and leaves. Do not open the lantern or touch the terminals. A clean window lets the sensor see movement again.
- **Whether other lights on that circuit work:** Turn on a light that shares the same breaker. Dark lamps on that breaker mean the fault is the circuit, not only the sensor. Lamps that work mean the fault sits at this lantern.
- **A walk past after dark:** Wait until it is properly dark, then walk across the front of the lantern. A lamp that stays off in daylight and lights after dark is following its lux setting. A lamp that stays off at night as well needs a test.

## When should I book for a sensor light not working?

Book Now when the lantern stays dark after the switch is on, one breaker reset has failed, and the sensor window is clean. A lantern that only lights in full dark can wait.
- **It stays off after dark:** The switch is on, other lights on that breaker work, and a walk past at night does nothing. The sensor, the lamp or the joint in the lantern has failed. Book Now for a test of that fitting.
- **The light trips the breaker:** The lighting breaker or RCD opens when the sensor tries to switch. Current is leaking to earth, or the lantern cable is shorted. Leave the breaker off. Another reset heats the joint.
- **Water, heat or a burning smell:** An outdoor lantern with water inside, a warm fitting or a burning smell needs that circuit left off. Use the breaker handle only. Keep your hands off the lantern screws and the fuse board cover.
- **It flashes or clicks and stays dim:** A click with no light, a brief flash, or a lamp that stays very dim points to a failing sensor module or LED driver. The fitting needs a test before the part is changed.

## What happens on a visit for a dead sensor light?

We test the lantern and the lighting circuit and name the failed part before anything is changed. The repair starts after you accept it.
- **Which lantern failed and when:** We ask which sensor light is dark, whether it fails by day and by night, and whether the breaker has opened. We look at the fuse board with the cover on and at the lantern on the wall. A wall lantern with a PIR sensor is a fitting we fit and repair.
- **Tests with the circuit switched off:** We switch off the lighting circuit at the breaker. A dead test checks the cable and the lantern while they are safe to handle. The readings separate a failed sensor, a failed lamp, a leak to earth and a break in the cable.
- **The failed part named before a change:** You hear the failed part before a sensor, a lamp or a lantern is changed. Earthing, the path that carries fault current, is checked on the visit. Bonding, the link from metal pipes to earth, and spare capacity on the supply are checked before any further price.
- **Repair and the minor works certificate:** Once you accept the repair we fit the failed part and test the circuit again. Where the circuit is altered we issue a minor works certificate under our NAPIT registration. If the lantern cannot be left live, that breaker stays off and the other circuits stay on.

## What does a sensor light fault visit cost?

Fault finding and repair is charged by the hour. That time covers tests on the sensor light and its circuit, the diagnosis we give you, and the start of the repair once you accept it. A lantern that only needs a new lamp takes less time than a cable fault back to the fuse board. A new part, a minor works certificate, or Lighting Installation as its own job changes the price.
- Fault finding & repair: from £75 an hour
- The hourly work pays for the tests, the spoken diagnosis and the repair of the part that failed, after you accept it.
- A sensor, a lamp or a length of cable is added only when the tests show that part has failed.
- Attendance under the emergency electrician service carries its own price, apart from the hourly fault finding.

## Questions about a PIR light not coming on

### Will you change the sensor light before you find the fault?

No. Testing comes first. We name the dead sensor, lamp, joint or cable, and the repair waits until you accept it. A lantern that tests sound stays where it is.

### Do I get paperwork after a sensor light repair?

Where the repair alters the lighting circuit, the minor works certificate lists those tests and our NAPIT registration. If we only isolate the lantern and change nothing, you still get the readings and the named part. An Electrical Installation Condition Report, called an EICR, is a separate full inspection of the installation.

### Can the rest of the lights stay on?

Yes. We switch off only the circuit that feeds the dead lantern. Every other circuit stays on, and that breaker goes back on after the repair unless the lantern cannot be left live.

### Is a new fuse board the fix for a dead sensor light?

The lantern needs a new fuse board where the lighting breaker or the board itself has failed the tests. A dead sensor still leaves the lantern dark on a sound board. Fuse board replacement then has its own written price.

### What if the lantern lights for a second and goes out?

A short flash means the sensor switches and the lamp or its driver fails to stay lit. We measure the lantern with the circuit switched off and name that part. The lamp or sensor is replaced on the visit once you accept the repair.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [NICEIC: Householder Guidance](https://niceic.com/householders/)

Updated 2026-11-16.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)