# Shaver socket not working

> Shaver socket not working in Peterborough? Lighting Electrical tests the circuit and the unit, then repairs the fault and leaves any paperwork needed.

Lighting Electrical tests a dead shaver socket from the fuse board outwards, finding whether the circuit, the isolating transformer inside the unit or a loose joint has lost the supply, then repairs it.

## Why has my shaver socket stopped working?

A bathroom shaver socket is a sealed unit on a protected circuit, so it can go dead while every other socket in the house carries on.
- **The RCD or a breaker has tripped:** An RCD is a switch in the fuse board that cuts power when current leaks to earth. Bathroom circuits are protected by one, so a trip caused elsewhere on that circuit can leave the shaver point dead.
- **It shares the bathroom lighting circuit:** Shaver points are often wired from the bathroom lighting circuit. When the light and the shaver point die together, a single fault upstream usually explains both.
- **The transformer inside the unit has worn out:** A shaver supply unit holds an isolating transformer, a sealed part that keeps the shaver apart from the mains. It can fail by itself while nothing else in the house is wrong.
- **A joint or terminal has worked loose:** A loose or scorched connection at the unit, or at the junction box feeding it, stops power arriving. Brown marks or a faint burning smell near the unit point this way.
- **A mirror light has its own fuse or switch:** Some mirror lights and bathroom cabinets carry a built in shaver point with a small fuse or switch of its own. When that operates, only the shaver point goes dead.
- **The shaver or its charger is the fault:** A faulty shaver can trip the supply the moment it goes in. If another device works in the same unit, the shaver is the likelier cause.

## What can I check myself without opening anything?

Everything here is done with dry hands at the fuse board and the bathroom wall. Nothing is unscrewed, and no wiring is touched.
- **Reset a tripped switch once:** Look at the fuse board for an RCD or breaker that has dropped and push it up one time. If it drops again, leave it off and keep it off.
- **Try the bathroom light:** A light that is dead as well points to the circuit feeding both, not to the shaver unit on its own.
- **Charge the shaver in another room:** Use the adaptor that came with it and follow the maker's instructions. If it works there, the shaver is fine and the bathroom point needs testing.
- **Look for a switch or fuse on a mirror light:** Some units have a small switch or fuse marked on the front. Make sure the switch is on before concluding anything else.
- **Leave the unit on the wall:** Do not fit an ordinary socket, run an extension lead in from another room or open the unit. Wet skin makes a bathroom a high risk place for shock.

## When should I book an electrician for a dead shaver socket?

Book Now when one reset has not brought the socket back, or when the unit looks damaged. A shaver point that stays dead needs testing, not repeated resets.
- **The socket stays dead after one reset:** Power is being lost somewhere between the fuse board and the unit, and only testing along the circuit shows where.
- **The breaker or RCD trips again:** A switch that keeps dropping points to a fault that resetting will not clear. Leave that circuit off until it has been tested.
- **The unit is cracked, brown or has got wet:** Keep it out of use. Water or heat damage inside a bathroom fitting needs checking before anyone plugs into it.
- **The bathroom light has failed too:** Two dead fittings on one circuit mean the fault sits upstream, at a joint or at the circuit protection.

## What happens on a shaver socket visit?

We start at the fuse board and the unit, then follow the supply along the circuit until we find the point where it stops.
- **Isolate the circuit and test it:** We switch the circuit off and measure at the fuse board, the junction box and the unit. The reading where power disappears names the failed part.
- **Check the RCD protection:** Circuits in or passing through a bathroom need RCD protection, so we confirm the circuit has it and that it operates.
- **Repair or replace the failed part:** A loose or heat damaged connection is remade. A failed unit is replaced with a proper shaver supply unit, never an ordinary socket.
- **Test again and leave the paperwork:** We test the circuit before power goes back on. Where the repair alters the circuit, we complete a minor works certificate under our NAPIT registration.

## What does the fault finding price cover?

Fault finding is charged by the hour, so the price covers the time we spend testing from the fuse board to the unit until the cause is named. It rises when the cause turns out to be a failed unit or damaged cable, because parts and the repair follow once we know what has failed.
- Fault finding & repair: from £75 an hour
- A replacement shaver supply unit, a junction box or any other part is added once the fault is found.
- A minor works certificate is added only when the repair alters the circuit.

## Electrical fault finding near you
- [Electrical fault finding in Colchester](https://lightingelectrical.co.uk/electrician-colchester/electrical-fault-finding)
- [Electrical fault finding in Heybridge](https://lightingelectrical.co.uk/electrician-heybridge/electrical-fault-finding)

## Questions about a dead shaver point

### Can I fit an ordinary socket in the bathroom instead?

No. Near the bath or shower only a shaver supply unit is allowed. An ordinary socket is permitted only when it sits at least 2.5 metres from the edge of the bath or shower tray, which most bathrooms cannot manage.

### Why is my shaver socket dead when the bathroom light works?

The two may be on different circuits, or the unit may have failed or lost a connection. We test along the circuit to find where the supply stops.

### Will you replace the shaver unit on the same visit?

Where testing shows the unit has failed, we fit a new shaver supply unit. If the part is not to hand, we price it in writing and book a return visit.

### Will I get a certificate after the repair?

A repair that alters the circuit comes with a minor works certificate. We work under NAPIT registration, and bathroom electrical work should always be done by a registered electrician.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Cooker switch not working](https://lightingelectrical.co.uk/problems/cooker-switch-not-working): A dead cooker usually means a tripped breaker, a failed cooker switch, a loose connection behind it or a fault inside the cooker itself.
- [Cooker tripping the electrics](https://lightingelectrical.co.uk/problems/cooker-tripping-electrics): A cooker trips the electrics when an element leaks current to earth, a connection overheats or the circuit carries more than it can bear.

## Sources
- [Electrical Safety First: bathroom safety](https://www.electricalsafetyfirst.org.uk/guidance/safety-around-the-home/bathroom-safety/)
- [Electrical Safety First: shavers](https://www.electricalsafetyfirst.org.uk/safety-advice/products-and-appliances/beauty-hygiene/shavers/)
- [GOV.UK: Approved Document P, electrical safety in dwellings](https://www.gov.uk/government/publications/electrical-safety-approved-document-p)

Updated 2026-11-20.

[Electrical fault finding](https://lightingelectrical.co.uk/services/electrical-fault-finding)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)