---
title: "Yellowed or discoloured socket face plate | 4.7 Star · NAPIT"
description: "Yellowed socket face plate in Peterborough: even colour is aged plastic, brown pin holes mean heat. Lighting Electrical tests and replaces the failed…"
canonical: "https://lightingelectrical.co.uk/problems/socket-face-plate-discoloured"
---

# Yellowed or discoloured socket face plate

> Yellowed socket face plate in Peterborough: even colour is aged plastic, brown pin holes mean heat. Lighting Electrical tests and replaces the failed…

A yellow socket face plate is aged plastic when the colour is even, and heat at the terminals when brown marks ring the pin holes. Lighting Electrical replaces the socket after testing the circuit.

## Why does a socket face plate go yellow?

A socket face plate goes yellow because the plastic has aged, sunlight has stained it, or heat from the terminals has cooked it. Even colour across the plate is different from a brown ring around the pin holes.
- **Aged plastic on the face plate:** Older white and cream plates yellow as the plastic ages, even when the terminals are tight. The whole plate shifts to the same shade, screws included. That colour on its own does not show a loose wire.
- **Sunlight on the socket:** A socket beside a window or on a sunlit wall yellows faster on the face the sun hits. The shaded edge stays nearer the original colour. Daylight does not heat the pins or the cable.
- **Heat at a loose terminal:** A loose or tired terminal resists current and turns that energy into heat. The plastic browns in a ring around the pin holes, darker at the live pin. The plate blisters while plates in the same room keep their original colour.
- **A heavy load left in the socket:** A heater, dryer or kettle draws a high current through the pins. On a worn socket that current heats the contacts and darkens the plate from the holes outward. The plug pins brown as well.
- **Smoke and cooking film:** Nicotine and kitchen grease coat a plate and turn it yellow brown. A damp cloth lifts grease and nicotine. Colour that remains, and sits only around the holes, is heat in the plastic.

## What can you check on a yellow socket?

You compare the colour, feel the plate after unplugging, and look for cracks or a burning smell. Every screw stays in place and the fuse board stays shut.
- **Even colour or a ring round the holes:** Stand where daylight hits the plate. The same yellow over the whole face, matching other plates, is ageing. A darker ring around the pin holes is heat, and that socket stays empty.
- **Whether the plate is warm:** Unplug every appliance from that socket and wait a few minutes. A sound plate feels no warmer than the wall. Warm plastic on an empty socket means heat is still in the terminals, so you leave it unused.
- **Cracks, blisters or a burning smell:** Look for a crack, a blister or brown dust at the holes. Smell the plate. Burning plastic means you stop using the socket. You do not take the fuse board cover off.
- **How the plug sits:** Push a plug in and see if it holds. A plug that droops or falls out makes a weak contact and heats the pins. Do not bend the pins and do not tape the plug in place.

## When should you book for a yellow socket?

Book Now if the plate is warm, brown around the holes, cracked, or smelling of burning. An evenly yellow plate that is cool and holds a plug firmly is booked as planned socket work.
- **Brown marks or a warm plate:** Brown rings, blisters or warmth mean the terminals are heating. Leave that socket empty. Book Now so the circuit is tested before the cable insulation hardens and cracks.
- **A burning smell or a cracked plate:** A burning smell, a crack or soot at the holes means the socket is already damaged. Switch that circuit off at the breaker handle if the fuse board is cool and quiet. Leave the cover screws alone.
- **Yellow plastic you want replaced:** A cool plate with even yellowing and a firm plug is aged plastic. Book Now when you want that socket changed. We test the circuit and fit the replacement as socket installation or replacement.

## What happens on a visit for a yellow socket?

We confirm which plate has discoloured, isolate that circuit, and test it before the face comes off. Sound cable gets a new socket. Burnt cable is priced before any further work.
- **Which socket and which circuit:** We look at the plate with you and note even yellowing or heat marks. We switch off the circuit for that socket and test that it is dead. No screw comes out until that test is clear.
- **Terminals and the cable behind:** With the circuit dead we take the face plate off and look at the terminals and the insulation. Tight copper with sound insulation means the plate is the failed part. Blackened copper or hard, cracked insulation means the cable needs repair before a new socket is fitted.
- **The new socket and the tests:** We fit the socket named on the quotation. That socket is MK Electric, BG Electrical or Contactum when the quotation names that brand. We then test earthing, bonding and the new point. Earthing is the fault path back to the breaker. Bonding links metal pipes to the earthing at the fuse board.
- **Certificate after the change:** A replaced socket comes with a minor works certificate that lists the test results and our NAPIT registration. If the cable is unsafe we leave that circuit off and write the fault for the next price. The other circuits stay on.

## What does replacing a yellow socket cost?

Replacing one discoloured socket covers isolating that circuit, fitting the new face plate, testing the point and the certificate for that change. The price changes when more than one socket is on the job, when the cable behind has burnt, when the wall needs making good, or when the fuse board itself has failed.
- Socket installation or replacement: from £85
- Each extra socket on the same visit is written as its own line on the quotation.
- Burnt cable is priced as Electrical Fault Finding & Repair after the test, separate from the single socket replacement.
- Plaster or paint is its own line, and fuse board replacement is a separate job when tests show the board has failed.

## Questions about a yellow socket

### Is a yellow socket dangerous?

Even yellowing on a cool plate is aged plastic and is not heat damage. Brown marks around the pin holes, a warm face or a burning smell mean the terminals are overheating. Leave that socket empty until we test the circuit.

### Can you replace the face plate on its own?

Yes, when the cable and the terminals test sound. That work is Socket installation or replacement, and the new plate is the one on the quotation. If the insulation has burnt, we price the cable repair before a new socket goes on.

### Will my power go off in the whole house?

No. Only the circuit for that socket is switched off while we work. The other circuits stay on. We put the socket circuit back on after the new point tests correctly, and we leave it off if the cable is damaged.

### What certificate do I get after the socket is changed?

A minor works certificate records the socket we changed and the tests we took, and it carries our NAPIT registration. An EICR looks at the whole installation and is quoted on its own when you want that inspection.

### Do you test the circuit before pricing more work?

Yes. We test earthing, bonding and spare capacity on the supply before we price work past the socket itself. Earthing is the fault path back to the breaker. Yellow plastic does not show those tests will pass.

## Related problems
- [Cracked plug socket](https://lightingelectrical.co.uk/problems/socket-cracked): A cracked plug socket stays unused until the face is replaced and the terminals behind it are tested.
- [Extension lead getting hot](https://lightingelectrical.co.uk/problems/overheating-extension-lead): A hot extension lead is overloaded, so the appliance needs a fixed socket instead of that lead.
- [Loose or wobbly plug socket](https://lightingelectrical.co.uk/problems/socket-loose): A loose plug socket has a moving faceplate or worn contacts, and we replace it after the circuit is tested.
- [One side of a double socket not working](https://lightingelectrical.co.uk/problems/double-socket-one-side-not-working): One outlet on a double socket goes dead when its contacts or switch fail and the other outlet still has power.
- [Sparks when turning on a socket](https://lightingelectrical.co.uk/problems/plug-sparks-when-turned-on): A spark as the socket switch closes means a worn socket contact or a damaged plug.
- [USB socket stopped charging](https://lightingelectrical.co.uk/problems/usb-socket-not-working): A failed charger inside the plate stops the USB ports while the plug outlets on that plate stay live.

## Sources
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [IET: BS 7671 Guidance Publications](https://electrical.theiet.org/guidance-and-codes-of-practice/publications-by-category/bs-7671-and-guidance/)
- [NICEIC: Householder Guidance](https://niceic.com/householders/)

Updated 2026-11-16.

[Socket installation](https://lightingelectrical.co.uk/services/sockets-and-switches)

## Book or ask a question
- [Book Now](https://lightingelectrical.co.uk/#chat)
