# Electric underfloor heating not working

> Cold underfloor heating in Peterborough sits in the thermostat, floor sensor, cable or breaker. Lighting Electrical tests the circuit and names the fault.

Cold electric underfloor heating means the thermostat, floor sensor, heating cable or breaker has cut heat to the mat. Lighting Electrical tests that heating circuit in Peterborough and tells you which part failed.

## Why is electric underfloor heating not working?

Electric underfloor heating stays cold when the thermostat, the floor sensor, the heating cable or the breaker stops power reaching the mat. Other circuits in the home can stay on.
- **The thermostat is not calling for heat:** The thermostat is the wall control that switches the mat on when the floor is cooler than the set temperature. A blank screen, a clock that has lost its time, or a set temperature below the floor leaves the mat off. The cable can still be sound.
- **The floor sensor is giving a false reading:** The floor sensor is a small probe in the floor that tells the thermostat how warm the surface is. An open or shorted probe makes the control treat the floor as already hot, or it shows a sensor fault. The mat then stays off.
- **The heating breaker has opened:** A breaker is the switch on the fuse board that guards one circuit. The mat is wired from a breaker in that board. The breaker opens on a short, an overload or a leak to earth. Earth is the safety path that carries fault current away from you.
- **The heating cable is open:** The heating cable is the wire under the floor that turns electricity into warmth. A later screw or a failed joint in the cold tail breaks that wire. A cold tail is the unheated lead from the mat to the thermostat. The mat never warms while the thermostat calls for heat.
- **Current is leaking from the mat:** An RCD is a safety switch that turns off when current leaks to earth. Damage or moisture in the heating cable causes that leak. The RCD, or the heating RCBO, then opens. An RCBO combines a breaker and an RCD for one circuit.

## What can I check safely on a cold floor?

You can read the thermostat screen, compare rooms and look at the fuse board with the cover left on. You do not open the thermostat, lift the floor or touch a cable.
- **The temperature on the thermostat:** Raise the set temperature well above the room and look for a heat symbol on the screen. A blank screen means the control has no supply or has failed. Leave the thermostat fixed to the wall.
- **The timer or the manual setting:** Many thermostats follow a daily timer. Select manual or constant heat with the buttons on the front. If the floor stays cold after that change, the timer is not the cause.
- **The heating switch on the fuse board:** Find the breaker marked for heating or for the floor, and read it through the closed cover. If it is down, and the board is cool, quiet and free of any burning smell, reset it once. If the switch opens again at once, leave the heating circuit off.
- **Whether one room or every room is cold:** A house with more than one heated floor may have a thermostat in each room. One cold room points to that control, its sensor or its cable. Every heated room cold points to the heating breaker or the RCD.

## When should I book for cold underfloor heating?

Book Now when the floor stays cold after the set temperature is raised, or when the heating breaker will not stay on. A thermostat left on a low setting is not this fault.
- **The floor stays cold on a high setting:** You have raised the set temperature and chosen manual heat, and the floor is still cold. The fault is in the control, the sensor, the cable or the breaker. More time on the same setting will not warm the mat.
- **The heating breaker will not hold:** The breaker opens again after one reset. The fault is still on the heating circuit. Further resets heat the breaker and the cable. Leave that switch off.
- **The thermostat shows a sensor fault:** A sensor warning, a flashing code or a blank screen, with the breaker still up, means the control or the probe needs a test. Leave the thermostat screwed to the wall.
- **Heat, a buzz or a burning smell:** A warm thermostat, a buzz or a burning smell means a joint is overheating. Switch the heating breaker off with the handle on the fuse board. Keep your hands off the thermostat screws and the board cover.

## What happens on an underfloor heating visit?

We test the cold heating circuit from the fuse board and the thermostat, and we name the failed part before anything is changed. Any repair waits until you accept it.
- **Which floors went cold and when:** We ask which rooms lost heat. We ask when the floor last felt warm. We read the thermostat screen with you and note any sensor warning. We look at the heating breaker through the closed fuse board cover.
- **Tests on the control, sensor and cable:** We switch the heating circuit off at its breaker. A dead test checks the cable while it has no power. We measure the floor sensor from the thermostat. We then measure the heating cable from the same point. The readings separate a failed control, a failed probe and an open or leaking cable.
- **Earthing and supply before a further price:** We tell you whether the thermostat, the sensor, the cable or the breaker has failed. A sound mat stays in the floor. We check earthing, bonding and whether the supply will carry the heating load before we price any further work. Earthing is the fault path that lets a breaker open. Bonding joins metal pipes to the fuse board.
- **The repair and the certificate:** We fit the failed thermostat, cable joint or breaker only after you accept that repair. We test the heating circuit again. Where that circuit was altered, we write a minor works certificate under our NAPIT registration. If the circuit is unsafe to leave on, the heating breaker stays off.

## What does underfloor heating fault finding cost?

Fault finding on a cold electric floor is charged by the hour. The price covers tests on the heating circuit, the diagnosis we give you, and the start of the repair once you accept it. Replacing a thermostat takes less time than tracing an open heating cable. A part, a minor works certificate or a separate fuse board replacement changes the price.
- Fault finding & repair: from £75 an hour
- A thermostat, breaker or cable joint is added only when the tests show that part has failed.
- Fuse board replacement is a separate written price when the heating breaker or the board has failed.
- Emergency electrician work is priced separately from Electrical Fault Finding & Repair.

## Questions about underfloor heating not working

### Will you lift the floor to find the fault?

We start at the thermostat and the fuse board, with the heating circuit switched off. Sensor and cable faults usually show on those tests without lifting the floor covering. Lifting the floor comes only if the readings show a break that cannot be reached from the thermostat.

### Do you replace the thermostat before you know the cause?

No. We test the control, the floor sensor and the heating cable first, and we name the failed part. Work on that part begins only after you accept the repair. A control that passes the test remains on the wall.

### Does a cold floor always mean the cable has failed?

No. A timer, a low set temperature, a failed floor sensor or an open breaker leaves a sound cable cold. We separate those parts with tests before any cable is written off. The mat is changed only when the readings show it has failed.

### What paperwork do I get after the repair?

Where the repair changes the heating circuit, we write a minor works certificate for that job. It records the tests for the work we finished, under our NAPIT registration. If we find the fault and change nothing, we tell you the readings and the failed part.

### Can the rest of the house stay on?

Yes. We switch off only the heating circuit that has failed. Lights and sockets on other breakers stay on. That heating circuit goes back on after a repair you have accepted, and it stays off if it cannot be left on.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)