# Underfloor heating thermostat not working

> Underfloor heating thermostat not working: Lighting Electrical in Peterborough tests the control, the floor sensor and the heating cable. · Prices from £60

A blank thermostat or a cold floor while the thermostat asks for heat means the control, the floor sensor or the heating cable has failed. Lighting Electrical in Peterborough measures the heating circuit and tells you the part that failed.

## Why has the underfloor heating thermostat stopped working?

The floor stays cold or the screen goes blank because the thermostat, the floor sensor or the heating cable has failed. Those parts all sit on the electric heating circuit.
- **The thermostat has lost power:** A breaker is the switch in the fuse board for one circuit. The heating breaker opens on a fault and cuts power to the thermostat. The screen goes blank and the floor stays cold.
- **The floor sensor has failed:** A floor sensor is the probe in the floor that reports temperature to the thermostat. An open sensor makes the thermostat treat the floor as already hot. It then stops sending power to the heating cable.
- **The heating cable is broken:** The heating cable is the wire under the floor that warms the room. A break in that wire stops the heat while the thermostat still asks for it. A fixing driven through the floor can open the wire.
- **The switch inside the thermostat has failed:** The thermostat switches the heating cable on and off. A switch that stays open leaves a normal screen and a cold floor. A switch that stays closed keeps the floor heating past the temperature you set.
- **The heating circuit is leaking to earth:** An RCD turns a circuit off when current leaks to earth. Earth is the safety path that carries fault current away from you. Worn insulation on the heating cable leaks current, so the RCD opens and the thermostat goes dark.

## What can I check on an underfloor heating thermostat?

You can read the thermostat screen, raise the set temperature, and look at the heating switch through the closed fuse board cover. Leave the thermostat, the floor and the fuse board unopened.
- **The set temperature against the room:** Read the figure for the room and the figure you asked the thermostat to hold. Heat stays off while the set figure is below the room figure. Use the buttons on the front to raise the set figure and watch for a heat symbol.
- **A blank thermostat screen:** A dark screen means the thermostat has no supply or has failed. See whether the heating switch on the fuse board sits down. Leave every screw in the thermostat face.
- **One reset of the heating switch:** Reset the heating switch once if the fuse board is cool, quiet and free of any burning smell. A switch that stays up can bring the screen back. A switch that opens again should be left down.
- **A hand on the floor:** Put a hand on the floor beside the thermostat. A cold floor with a heat symbol on the screen means the cable is not warming. A warm floor means the cable is still heating.

## When should I book for an underfloor heating thermostat fault?

Book Now if the screen stays blank, the floor stays cold while the thermostat shows a heat symbol, or the heating switch opens again after one reset.
- **The screen will not light:** The heating switch is up and the screen is still dark. Power is missing at the thermostat or the thermostat has failed. Pressing the front buttons again will not bring the screen back.
- **The floor stays cold on a heat symbol:** The screen shows that the thermostat is asking for heat. The floor beside it stays cold. The floor sensor or the heating cable needs a test with the circuit switched off.
- **Heat or a burning smell:** A warm thermostat or a smell of burning means a connection inside is overheating. Turn the heating circuit off with the switch handle on the fuse board. Keep the thermostat cover closed.
- **The heating switch will not hold:** The switch opens straight after one reset. Current is still leaking or the cable is shorted. Leave the switch down so the cable and the thermostat do not keep heating up.

## What happens on a visit for an underfloor heating thermostat?

We test the underfloor heating circuit first and say which part failed before we fit anything. The repair of that part starts after you accept it.
- **What you have already seen:** We ask which room is cold, what the screen shows, and when the floor was last warm. We look at the heating switch with the fuse board cover left on. We note a reset you have already tried.
- **Measurements with the circuit off:** We switch the heating circuit off at its breaker. We measure the supply at the thermostat, the signal from the floor sensor, and the continuity of the heating cable. Continuity means the copper still joins end to end.
- **Earthing and load before a further price:** We check earthing, bonding and whether the supply can carry the heating load before we write a further price. Earthing gives fault current a path back to the fuse board. Bonding joins the metal pipework to the earth at the fuse board.
- **The repair and the certificate:** After you accept the repair we fit the failed thermostat, sensor connection or protective device and test again. A minor works certificate records that job on our NAPIT registration. A heating cable that has failed under the floor is priced as its own job.

## What does an underfloor heating thermostat visit cost?

Electrical Fault Finding & Repair for this fault is billed by the hour. That hour includes measurements at the thermostat and the fuse board, a spoken diagnosis, and the first repair after you accept it. Fitting a thermostat, a floor sensor or issuing a minor works certificate changes the price.
- Fault finding & repair: from £75 an hour
- A thermostat or a floor sensor is fitted only when measurements show that part has failed.
- A heating cable under the floor is priced as its own job when the cable has failed.
- Emergency electrician work sits apart from the hourly fault finding on this visit.

## Questions about underfloor heating thermostat faults

### Will a new thermostat warm the floor?

A new thermostat warms the floor only when the old thermostat has failed. A broken floor sensor or heating cable stays cold behind a new control. We name the failed part before we fit a replacement.

### Can the other circuits stay on?

We switch off only the heating circuit. Lights and sockets on other breakers stay in use. The heating circuit returns after a repair you accept, and it stays off if it is unsafe to energise.

### What certificate do I get after the repair?

You get a minor works certificate when we change the thermostat, the sensor connection or the protective device. The certificate lists the tests for that job and our NAPIT registration. Readings alone are left with you when we change no part.

### Do you lift the floor if the cable has failed?

We do not lift the floor on the fault finding hour. The tests show whether the heating cable is complete. Lifting the floor to replace a failed cable is priced as its own job.

## Related problems
- [Automatic gate not opening](https://lightingelectrical.co.uk/problems/electric-gate-not-working): A gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- [Buzzing sound in the wall](https://lightingelectrical.co.uk/problems/buzzing-in-walls): A buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- [Circuit breaker keeps tripping](https://lightingelectrical.co.uk/problems/circuit-breaker-keeps-tripping): The breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- [Consumer unit tripping with nothing plugged in](https://lightingelectrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): The consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- [Downstairs circuit keeps tripping](https://lightingelectrical.co.uk/problems/downstairs-circuit-keeps-tripping): The downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- [Driveway lights not working](https://lightingelectrical.co.uk/problems/driveway-light-not-working): Driveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.

## Sources
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [NICEIC: Householder Guidance](https://niceic.com/householders/)

Updated 2026-11-16.