---
title: "Appliance and heating connections in Colchester — Lighting Electrical"
description: "Cooker and oven connections, electric shower installation, extractor fans and immersion heater repairs. See published prices and what is included."
canonical: "https://lightingelectrical.co.uk/services/appliance-connections"
last_updated: "2026-08-05T08:29:55.282Z"
---

# Appliance and heating connections in Colchester — Lighting Electrical

> Cooker and oven connections, electric shower installation, extractor fans and immersion heater repairs. See published prices and what is included.

Cooker and oven connections, electric showers, extractor fans and immersion heater repairs.

## What appliance work costs

Each published price assumes a suitable circuit already exists in the right place. Where the appliance needs more current than the existing circuit can carry, a new circuit is surveyed and priced separately.
- Cooker or oven connection: £120
- Electric shower installation: £220
- Extractor fan installation: £180
- Immersion heater repair: £70/hr
- Quotes are free and there is no call-out charge.
- Electric showers and cookers often need their own circuit, which is confirmed before the work is agreed.
- A certificate is issued for the work carried out.
- Plumbing connections for showers are not included and are handled by a plumber.

## The circuit decides the job

The appliance is rarely the hard part. Whether the existing circuit can feed it is.
- **Cooker and oven connections:** A freestanding cooker or built-in oven connected at a cooker control unit, on a circuit rated for its load.
- **Electric showers:** High current draw, so almost always a dedicated circuit with its own protection.
- **Extractor fans:** Bathroom fans have specific rules on zones, isolation and overrun that decide where switching goes.
- **Immersion heaters:** Usually a repair rather than an install: failed element, failed thermostat or a tripping circuit.

## What the work covers

The quote assumes a suitable existing circuit and says so where a new one is needed.

### Included when agreed
- Checking the existing circuit is suitable for the appliance
- Connecting the appliance and its isolation
- Testing the circuit after connection
- A certificate for the work carried out
- Taking the old unit away where you want that

### Not included automatically
- New circuits back to the consumer unit, priced after survey
- Plumbing work, including shower water connections
- Supplying the appliance itself
- Building work, tiling or making good

## How the visit works

A photo of the existing connection point and the appliance rating plate settles most of this in advance.
1. **Check the rating and the circuit:** The appliance load is compared against what the existing circuit can carry.
2. **Confirm before starting:** If a new circuit is needed you hear that before work begins, not afterwards.
3. **Connect and test:** The appliance is connected, isolated correctly and the circuit tested.
4. **Demonstrate and hand over:** You are shown the isolation point and given the certificate.

## What you are left with

Correct protection matters more than the connection itself on these circuits.
- **A properly fed appliance:** On a circuit rated for what it actually draws.
- **Accessible isolation:** You can turn it off safely without going to the consumer unit.
- **Certification:** Paperwork covering the connection.

## Appliance connection questions

Clear answers before you request a quote.

### Can I connect a cooker to a normal socket?

Some smaller ovens are supplied with a plug and can. Most freestanding cookers draw far too much and need a dedicated circuit at a cooker control unit.

### Does an electric shower need its own circuit?

Almost always. They draw a lot of current and sharing a circuit is not acceptable.

### Do you do the plumbing for a shower?

No. The electrical supply, isolation and testing are covered; the water connection is a plumber's work.

### My immersion heater trips the electrics. Is that the element?

Often, but not always. Testing separates a failed element from a thermostat fault or a problem on the circuit.

### Where does a bathroom fan isolator have to go?

Outside the bathroom zones, and the switching arrangement depends on whether the fan has a timer overrun. That is set out at the visit.

### Can you replace like for like quickly?

Yes, where the existing circuit is suitable. That is confirmed first rather than assumed.

## Business facts
- Based: 12 Rangoon Close, Colchester, CO2 9RH
- Service area: Colchester, Witham, Maldon, Wivenhoe, Tiptree, Kelvedon, West Mersea, Stanway, Brightlingsea, Coggeshall, Marks Tey
- Hours: Mon, Tue, Wed, Thu, Fri 09:00–17:00
- Phone: +447414545781
- Email: team@lightingelectrical.co.uk

## Request a quote
- [Start a request](https://lightingelectrical.co.uk/#chat): Send the job details and postcode to Lighting Electrical.

## Related pages
- [Socket and switch installation](https://lightingelectrical.co.uk/services/sockets-and-switches): Sockets and switches in Colchester.
- [Fuse board replacement](https://lightingelectrical.co.uk/services/fuse-board-replacement): Fuse board replacement in Colchester.
- [Electrical Fault Finding & Repair](https://lightingelectrical.co.uk/services/electrical-fault-finding): Electrical fault finding in Colchester.
- [House Rewiring](https://lightingelectrical.co.uk/services/house-rewiring): House rewiring in Colchester.
- [Full sitemap](https://lightingelectrical.co.uk/sitemap.md): Complete machine-readable page directory.
