Lights dim when an appliance turns on
Lights dim when an appliance starts because its heavy current pulls voltage down along the wiring. Lighting Electrical tests the circuit, board and connections in Peterborough and repairs the weak point behind the dip.
Calls answered 24/7
- 10 years trading
- Local to Peterborough
Not sure? We'll check for you.
Why do lights sag the moment a heavy appliance starts?
Every appliance pulls current, and the wiring loses a little voltage carrying it. Lights on the same supply show that loss as a dip.
- A heavy load on a shared circuitA kettle, heater or shower pulls far more current than a lamp. Where lights and the appliance share a feed, or the cable run is long, the voltage at the lights falls while it works.
- A loose terminalA slack screw at a socket, switch, junction box or the board adds resistance. Under load it wastes voltage as heat, so the dip deepens over time and the fitting can scorch.
- A weak neutral connectionThe neutral is the conductor that carries current back to the board. If that joint weakens, a big load on one circuit can dim lights elsewhere and make others flare brighter.
- A motor kicking inFridges, freezers, pumps and washing machine motors draw a short surge as they start. A blink lasting about a second is that surge and needs no work.
- Low voltage arriving at the propertyIf the voltage reaching the meter already sits low, or the incoming cable is small for the loads added since, every heavy appliance pushes it lower. A reading at the main switch shows which side the loss is on.
What can I check safely without opening anything?
Watching is enough. Leave every cover, faceplate and appliance casing shut, and never touch gas, refrigerant or wiring.
- Name the appliance and the lightsWrite down which appliance sets it off, which lights dip, and whether the dip is a blink or lasts while the appliance is on. A long dip points at the wiring.
- Walk round while it runsOne room dimming points at one circuit. Every room dimming together points at something nearer the board or the incoming cables.
- Try the same appliance elsewherePlug it into a socket in another part of the house, only if its plug, lead and casing are undamaged, and never through an extension lead. A smaller dip there tells us which circuit to test first.
- Look at the plug and socket after useBrown marks, cracking or a warm feel to the back of your hand mean a connection is overheating. Stop using that socket and tell us.
When is a dimming light worth a visit?
Book Now when the dip holds for the whole time the appliance is on, grows, reaches every room or comes with heat or a smell. A quick blink as a freezer motor kicks in needs no visit.
- Every room is affectedLights going down together in all rooms point at something upstream of the lighting circuits, at the board or the incoming cables. That is where testing starts.
- The dip is deeper than it wasA joint that heats under load slackens a little more each time. A dip worse than last month means the connection is getting worse.
- Lights flare brighter as well as dimBrightening when another load switches on can point at a failing neutral. Keep that appliance off until the circuit has been tested.
- Heat, buzzing or a burning smellSwitch the appliance off and leave that socket unused. If the board itself feels warm, turn off the main switch only if you can reach it safely from a dry spot.
What happens on the visit?
We watch the dip happen, measure it, then follow it to the joint or cable behind it.
- We watch it happenWe ask which appliance causes it and which lights react, then run it. The board and nearby sockets get a look for heat marks and discoloured plastic.
- We measure voltage under loadA meter reads the voltage at the board and at an affected light, with the appliance off and then on. The size of the fall at each point shows where the loss begins.
- We test the circuit with the power offValandi Kotorri checks the earthing, the bonding and whether the supply will carry the load, then tests terminals and cable along the suspect circuit before anything is priced.
- We repair or make it safeA slack terminal, scorched accessory or unsuitable dimmer is put right on the visit where the part is on the van. Bigger work gets a written price first, and a minor works certificate follows when the repair needs one.
What does the hourly price cover on a dimming lights call?
Fault finding is charged by the hour. That time pays for watching the dip, measuring voltage under load, testing the circuit and starting the repair once you accept it. The total moves with how deep the cause sits.
From £75 an hour
Included when agreed
- Testing at the board and along the failed circuit until the cause is named
- A spoken diagnosis before any part is swapped
- Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
- Making the circuit safe if it cannot be left live that day
- A minor works certificate when the repair needs one
Not included automatically
- A full house rewire or a new consumer unit as the first step
- Solar, battery, EV charger or forklift charger work
- Guesswork replacement of parts that have not failed
Ways to pay


- Pay by bank
- Bank transfer
- A loose terminal at a reachable socket takes less time than a joint buried in a wall or under a floor.
- Parts such as a socket, switch or dimmer are added once testing names the one that failed. A certificate is added only when the repair needs it.
- If the tests show a heavy appliance should have its own feed, or the board cannot carry it, that work gets its own written price.
Electrical fault finding near you
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 63
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowHow much does it cost to find why my lights dim?
Fault finding is charged by the hour, so the cost follows the time the cause takes to reach. Parts or a certificate are added only if the repair needs them, and larger work is priced in writing before it starts.
Will you change parts before you know the cause?
No. We test first and name the failed joint, accessory or cable. Replacement starts once you accept the repair.
Can you find a dip that only happens sometimes?
Intermittent faults often still leave traces at the board or along the circuit. If the dip does not show on the day, we tell you what we found and what to keep watching.
Do I get paperwork after the repair?
A minor works certificate comes with a repair that alters a circuit. Lighting Electrical is registered with NAPIT for that paperwork.
Related problems
- Automatic gate not openingA gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- Buzzing sound in the wallA buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- Circuit breaker keeps trippingThe breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- Consumer unit tripping with nothing plugged inThe consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- Cooker switch not workingA dead cooker usually means a tripped breaker, a failed cooker switch, a loose connection behind it or a fault inside the cooker itself.
- Cooker tripping the electricsA cooker trips the electrics when an element leaks current to earth, a connection overheats or the circuit carries more than it can bear.
Sources
- BS 7671: IET Wiring Regulations (18th Edition)
- Electrical Safety First: Safety Guidance
- Energy Networks Association: Power Cut Information
Updated 20 November 2026
