Dimmer lights flicker when the lamps and the dimmer do not suit each other, or a connection on the lighting circuit is loose. Lighting Electrical in Peterborough finds the wrong dimmer or the loose joint.
Calls answered 24/7
- 10 years trading
Why do dimmer lights flicker?
Dimmer lights flicker when the dimmer cannot control the lamps on it. They also flicker when a connection on that lighting circuit is loose.
- Lamps that do not suit the dimmerMany LED lamps need a trailing edge dimmer, which switches off the end of each mains wave. An older leading edge dimmer switches off the start of the wave and makes those lamps flicker. The lamp packet names the type it needs. Varilight and MK Electric make both types.
- Too small a load for the dimmerOlder dimmers need a minimum load in watts before they hold steady. A few low wattage LED lamps sit under that minimum, so the light pulses near the bottom of the slider. A dimmer made for LEDs holds that smaller load.
- Mixed lamps on one dimmerOne dimmer that feeds both filament lamps and LEDs sees two different loads. The lamps then flicker at different places on the slider. Every lamp on that dimmer needs to be the same type.
- A loose joint behind the dimmerSwitching and heat loosen the terminals behind the dimmer plate. A loose live, or the switched live that the dimmer turns on and off, makes the lamps flicker as the joint moves. The plate stays fixed until the lighting circuit is isolated and tested.
- Extra lights on one lighting circuitA lighting circuit carrying many extra fittings dips in voltage when several lights come on together. The lamps then flicker or fade as one group. We check that the supply can carry the load before we price a new dimmer or more lights.
What can I check safely on a flickering dimmer?
You can move one lamp, read the dimmer face and see which lights flicker. The dimmer plate, the ceiling rose and the fuse board cover stay shut.
- A lamp moved to a plain switchSwitch the flickering lamp off at the wall. Fit that lamp in a fitting on a plain on off switch. Steady light there means the dimmer or its circuit is at fault. Flicker there means the lamp or the driver inside it has failed. The driver is the small power unit in an LED lamp.
- Where on the slider the flicker startsMove the slider slowly from low to full. Flicker only near the low end points to a dimmer that cannot hold a small LED load. Flicker at every setting on every lamp points to the dimmer or a loose joint.
- The writing on the dimmer and the lampRead the dimmer face for an LED mark, trailing edge or a wattage range. Read the lamp box for dimmable and for leading edge or trailing edge. A lamp marked not dimmable flickers on any dimmer.
- Heat, a buzz or a burning smellA warm plate, a buzz or a smell of burning means a terminal is sparking. Leave the plate screws in. If the fuse board is cool, use the lighting breaker handle to switch that circuit off. Keep the cover shut.
When should I book for flickering dimmer lights?
Book Now when suitable lamps still flicker, or when the dimmer plate is hot, buzzing or smelling of burning.
- Suitable lamps still flickerYou have fitted dimmable lamps of one type and the lights still flicker or buzz. The dimmer, a joint or the lighting circuit needs a test. Fitting more lamps will not name the failed part.
- The plate is hot, loud or smellsHeat, a hard buzz or a burning smell means the terminals are failing. Switch the lighting circuit off at the breaker handle. Leave every screw in the plate.
- Lights on more than one switch dip togetherLamps on separate switches flicker at the same moment. The fault sits beyond one dimmer, in the lighting circuit or at the fuse board. That circuit needs a test before any dimmer is changed.
What happens on a visit for flickering dimmers?
We isolate the lighting circuit, test the dimmer and the lamps, and name the failed part before anything is changed.
- Which lights flicker and which circuit is offWe ask which rooms flicker and whether it is worse when the slider is low. We note any lamp you have already moved. We switch the lighting circuit off and prove it dead before the dimmer plate comes off.
- Tests at the dimmer terminalsWith the circuit dead we check each terminal for a loose conductor. We then test the live circuit and read how the dimmer behaves with your lamps. The readings separate a wrong dimmer, a loose joint and a failed lamp driver.
- The other lamps and the lighting cableWe check that every lamp on that control is dimmable and of one type. If more than one switch flickers, we test the lighting cable and its breaker. A dimmer that passes the test is left in place.
- Repair, certificate and the next priceAfter you confirm the repair, we change the failed dimmer, lamp or joint. We test the circuit again. A minor works certificate records an alteration and shows our NAPIT registration. Before a further price we check earthing, bonding and spare capacity on the supply. Earthing carries fault current away. Bonding is the metal link between pipes and the fuse board earth.
What does a flickering dimmer visit cost?
The price covers the tests on the dimmed lighting circuit, the diagnosis we give you, and putting right the failed dimmer or joint after you confirm that repair. A new dimmer, lamps you ask us to bring, or a minor works certificate changes the price. Lighting Installation covers a new lighting circuit, priced in writing before that work starts.
From £65
Included when agreed
- Fitting of downlights, pendants, wall lights or outdoor lanterns you have chosen
- Connection onto the existing lighting circuit where that circuit is sound
- Replacement of the matching switch or dimmer for those lights
- Removal of the old fittings we take down
- A minor works certificate when the job needs one
Not included automatically
- A full house rewire or a new consumer unit
- Decorative plaster repair beyond the hole for the fitting
- Lamps, shades or fittings you have not bought or left for us
Ways to pay


- Pay by bank
- Bank transfer
- A Varilight, MK Electric or BG Electrical dimmer is fitted only after the test shows the old one has failed or cannot run the lamps.
- Light switch or dimmer replacement is the job when the circuit tests sound and you want a new control for the lamps you have.
- Tracing flicker across several switches takes longer than testing one dimmer plate.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowCan you fit a dimmer that works with my LED lamps?
Yes. We fit a dimmer matched to those lamps, including Varilight and MK Electric models made for LEDs. We test the lighting circuit first. We change the dimmer when the test shows it is the wrong type or it has failed.
Will new lamps stop the flicker?
New lamps stop the flicker when the old ones were not dimmable or were mixed on one dimmer. They do not stop it when the dimmer terminals are loose or the dimmer cannot hold a small LED load. We name which of those it is before any part is fitted.
Do I get paperwork after a dimmer is changed?
A minor works certificate comes when we alter the circuit to change a dimmer or a joint. It lists the tests for that job and our NAPIT registration. A lamp change with the wiring left as it is does not need that certificate.
Does a new fuse board stop dimmer flicker?
A new fuse board stops the flicker only when the tests show the lighting breaker or the board has failed. A wrong dimmer or a tired lamp driver flickers on a fuse board that tests healthy. Fuse board replacement waits for a separate written price after those tests.
Can you fit a dimmer I have already bought?
Yes, when that dimmer suits the lamps and the lighting circuit. Bring the make and the lamp type so we can check the rating before we connect it. A dimmer that does not suit the lamps is left unfitted.
Related problems
- Dimmer switch not workingA dimmer stops working when its module fails, the lamps cannot dim, or the lighting circuit opens.
- Lights flickering after a new fittingA new fitting flickers when the lamp, the dimmer or a loose joint does not suit the lighting circuit.
- Pull cord light switch not workingA dead pull cord is a worn ceiling switch, a failed lamp, or an open lighting circuit.
- Why is my ceiling light buzzingA buzzing ceiling light is a loose joint, a failing lamp or a dimmer that does not suit the lamp.
- Why is my dimmer switch humming?Hum comes from lamps that do not suit the dimmer, or from a loose joint in the switch.
- Wires hanging from the ceilingHanging ceiling wires are cable ends left outside a rose, and the lighting circuit is isolated before they are refitted.
Sources
- Electrical Safety First: Safety Guidance
- BS 7671: IET Wiring Regulations (18th Edition)
- NICEIC: Householder Guidance
Updated 16 November 2026