Half the house has no electricity
On a board with two RCDs, half the house going dark means one has tripped and taken its circuits with it. Lighting Electrical in Peterborough tests those circuits one by one and puts the sound ones back on.
Calls answered 24/7
- 10 years trading
Why has half the house lost power?
When only part of the house goes dark, the fault sits with one device or one feed that serves some of the circuits, not with the whole supply.
- One RCD has tripped on a dual RCD boardAn RCD, or residual current device, cuts power when current leaks to earth. Many consumer units, the fuse board, split the circuits between two RCDs. When one trips, every light and socket behind it goes off while the other half carries on.
- A faulty appliance on the dead halfA kettle, washing machine, immersion heater or an outdoor socket with damp inside can leak enough current to trip the RCD it sits behind. The trip lands on whichever half that appliance is connected to.
- Small leaks adding upSeveral appliances can each leak a little current to earth. Together they push one RCD over its trip level, so it drops at odd times rather than when one thing is switched on.
- A second board has lost its feedAn extension, garage or annexe sometimes runs from its own small board, fed by a cable from the main one. If the breaker for that feed trips, everything on the second board goes dark at once.
- A fault on the network cablesA fault in the street can leave a home with only part of its supply. Lights may glow dimmer or brighter than normal. The network operator repairs this, and nothing inside the house needs touching.
- A burnt terminal inside the boardThe busbar is the metal bar inside the board that feeds a row of breakers. A loose or burnt terminal on it can cut that row while the rest keeps working. Heat marks or a burning smell near the board point to this.
What can I check safely before booking?
You can look at the switches on the front of the board, unplug appliances and see what the lights and the street are doing. No cover comes off the board, a socket or a switch.
- Find the RCD that has droppedLook along the board for a wider switch with a small test button, sitting lower than its neighbours. That is the RCD for the dead half. Reset it a single time.
- Unplug everything on the dead halfIf it drops again, unplug every appliance in the dead rooms and turn off fixed items such as the immersion at their own switch. Reset once more, then reconnect each item in turn until the trip returns.
- Look for a second boardIf the dead rooms are in an extension, garage or annexe, look for a small board out there. Then check the main board for a dropped breaker that feeds it.
- Watch the lights and the streetLights that flicker, dim or glow too bright, or neighbours with the same trouble, point to the network. Call 105, the national number for power cuts, and leave the board alone.
When should I book an electrician for half the house?
Book when the RCD will not hold with the dead half unplugged, when trips keep coming back, or when the board shows heat. A network fault goes to 105 first.
- The RCD trips with nothing plugged inA trip with every appliance off points to a leak in the fixed wiring, such as damp in an outside light or a damaged cable in a wall. Finding it takes test instruments, not more resets.
- The trips come back days laterAn RCD that holds for a while and then drops again often means small leaks that only add up when the shower, heating or washing machine runs.
- Heat, crackling or a burning smell at the boardTurn off the main switch if you can reach it safely, then keep clear. A burnt terminal sits behind the board cover, and opening that is electrician work.
- A leak or flood near the electricsLeave the dead half off after water gets into a ceiling, a wall or an outside fitting. Wet circuits are dried out and tested before they go back on.
What happens on an emergency visit for half power?
The visit works outward from the board: confirm the incoming supply, find which circuits share the tripped RCD, then test them one at a time.
- Which rooms are dead and what was runningWe ask when the power went, what was on at the time and what you have tried. Then we match the dead rooms to the RCD or breaker that serves them.
- Measuring the supply at the boardWe measure the voltage arriving at the board. A low or unsteady reading means a network fault, and 105 gets the reading we took.
- Testing each circuit behind the RCDWith the circuits isolated, we run insulation resistance tests, which show how much current escapes to earth on each one. A damp fitting or a nicked cable gives a low reading.
- Clear circuits back on, the faulty one made safeCircuits that test clear go back on the RCD. The faulty one stays isolated until it is repaired, and anything bigger is priced in writing first. A repair that alters a circuit comes with a minor works certificate.
What does an emergency visit for half power cost?
The price is hourly. It pays for attendance, testing at the board and along the dead circuits, and making the house safe. How long the leak takes to find moves it most: one damp appliance shows quickly, while a damaged cable inside a wall takes longer.
From £90 an hour
Included in the call-out
- Attendance at the property in Peterborough or a nearby Essex town
- Isolation of the failed circuit, fitting or board
- Fault finding on the circuit that has gone down
- Temporary making safe so the rest of the installation can be used where that is possible
- A written note of what failed and what work should follow
Not included automatically
- A full house rewire or a planned consumer unit replacement on the same visit unless already quoted
- Parts we do not carry in the van, which we price in writing before we fit them
- Work on another trade such as gas, plumbing or structural fabric
Ways to pay


- Pay by bank
- Bank transfer
- Parts such as a replacement RCD, socket or outside light are added to the time on site.
- A visit inside opening hours is charged at the fault finding rate, which differs from the out of hours rate.
- If the board itself needs replacing, that work is priced in writing before it goes ahead.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowIs half power a power cut or a fault in my house?
Dim or flickering lights, or neighbours with the same trouble, point to the network, so call 105. Normal lights on the working half and one dropped RCD mean the fault is inside the house.
Will a new fuse board stop the RCD tripping?
Not on its own. A board with an RCBO, a breaker and RCD in one, on each circuit means a fault trips only its own circuit instead of half the house. The leak behind the trip still has to be found and fixed.
Can the fridge and freezer stay on while you test?
They can when their circuit tests clear. Circuits are tested one at a time, and each sound one goes back on as it finishes.
Can I keep using the working half until the visit?
The working half sits behind its own RCD and can be used as normal unless the board feels hot or smells of burning. Leave the tripped RCD down if it will not hold.
Related problems
- Brown marks on a socket or plugBrown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- Burning plastic smell from electricsA burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- Burning smell from a socketA burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- Burning smell from the fuse boxA burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- Electric shock from a light switchA shock from a light switch means the switch face is carrying current and that lighting circuit should be isolated.
- Electric shock from the showerA shock from the shower means current is on the water, the case or the taps, so that circuit stays off until it is tested.
Sources
- BS 7671: IET Wiring Regulations (18th Edition)
- Electrical Safety First: Safety Guidance
- Energy Networks Association: Power Cut Information
Updated 16 November 2026