Aico smoke and heat alarms in Peterborough

Lighting Electrical fits and repairs Aico mains smoke and heat alarms in Peterborough, linking every head so a fire in the kitchen also sounds the alarm on the landing and in the bedrooms.

Calls answered 24/7

  • 10 years trading

Which Aico smoke and heat alarms do you fit?

We fit Aico Ei3000 series mains alarms: optical smoke, heat and multi sensor heads, linked by cable or by radio. Each alarm takes a mains feed, and every head in the house sounds when one of them detects a fire.

  • Aico Ei3000 smoke, heat and multi sensor alarmsThe Ei3016 optical smoke alarm goes in halls and landings, and the Ei3014 heat alarm goes in kitchens. The Ei3024 multi sensor reads smoke and heat together, which cuts false alarms in living rooms. Each one runs on mains with a rechargeable lithium cell that keeps it working through a power cut.
  • Wired interconnect and RadioLINK+Interconnect is the link that makes every alarm sound when one detects a fire. We run it as a third core in the alarm cable, or fit Ei3000MRF RadioLINK+ modules so the heads link by radio. An Ei450 controller lets you test, silence and find the triggered alarm from one switch.
  • Aico faults and warning lights we fixA yellow light on an Ei3000 head marks a fault, and its flash pattern shows whether the sensor, the backup cell or the alarm's working life has failed. We also read the AudioLINK+ report from Ei3000 alarms through the Aico app. We clear false alarms from dust or steam, chirping heads and linked sets that sound with no fire.
  • What servicing Aico alarms involvesWe press the test button on each head and check every linked alarm sounds. We confirm the green mains light, vacuum the vents and read the replace by date on the side. A head past its date comes off, and a new Ei3000 head clips onto the existing base.

Aico’s website

Where do Aico alarms come into each service?

EICR testing in Peterborough

EICR

from £150

An EICR is the condition report on the fixed wiring, so it covers the circuit feeding the Aico alarms. We record which breaker feeds them, test that circuit's insulation and earth, and note it if the alarms sit on a circuit someone could switch off without noticing.

Fuse board replacement

Consumer unit replacement

from £450

The Aico heads keep working on their backup cells while the old board comes out. On the new consumer unit, the box of breakers, the alarm circuit gets a clearly labelled way. Once the power is back, we check each green mains light and press test to confirm every head sounds.

House rewiring in Peterborough

House rewiring

from £2,400

A rewire is the time to run fresh three core and earth cable between alarm positions. That carries live, neutral and the interconnect to every Aico base. We fix new Ei3000 bases to the ceilings, clip the heads on last and test the whole set together.

Electrical fault finding

Electrical fault finding

from £75 an hour

An Aico set that sounds with no fire, or a breaker that trips on the alarm circuit, gets traced head by head. We test the interconnect core for stray voltage, read each yellow light and replace only the head or cable that has failed.

Lighting installation

Lighting installation

from £65

New ceiling lights go in at least 300mm from any Aico alarm, as BS 5839 Part 6 sets for detectors. Where a downlight plan would crowd an alarm, we move the alarm base on its existing cable rather than leave it beside a fitting.

EV charger installation

EV charger installation

from £750

The charger has no Aico part. In an attached garage we add an Aico Ei3014 heat alarm linked to the house alarms, so a fire beside the car sounds in the bedrooms. A heat alarm suits a garage because exhaust fumes set off smoke alarms.

Socket and switch installation

Socket installation

from £85

Socket work leaves the Aico alarms alone, because we never feed alarms from a socket circuit. When a room is being replanned with new sockets, we can move an alarm head on the same visit so it sits in the right spot for the new layout.

Emergency electrician

Emergency electrician

from £90 an hour

When every Aico alarm in the house is sounding with no smoke, or one head chirps all night, we find the head that started it. We silence the set, take the faulty head off its base and leave the rest of the alarms working. A replacement head follows.

Electrical testing and certificates

Electrical testing and certificates

from £95

PAT testing covers plug in appliances, and Aico alarms are fixed to the ceiling, so they sit outside it. On a PAT visit we test the portable kit. For the alarms, we press each test button and check that every linked head sounds.

Fire and smoke alarm installation

Aico smoke alarm installation

from £110

This is the main Aico job. We fit Ei3016 smoke alarms in the hall and on each landing, an Ei3014 heat alarm in the kitchen and Ei3024 multi sensors where rooms need them. We link them by cable or RadioLINK+, test the full set and leave the paperwork.

Appliance and heating connections

Appliance and heating connections

from £120

Connecting an electric cooker or oven needs no Aico part. If the kitchen has an Aico smoke alarm that goes off whenever you cook, we swap it for an Ei3014 heat alarm on the same Ei3000 base while we are there.

Solar and battery storage

Solar panel and battery storage installation

from £5,500

Panels and inverters carry no Aico part. In the loft, we run the new solar cables clear of the alarm cable above the landing ceiling. Once the inverter is live, we test that every Aico head still sounds when one is triggered.

Forklift charger installation

Forklift charger installation

from £700

Aico makes alarms for homes, and a warehouse charging bay is covered by the building's fire alarm system instead. We fit the forklift charger, its isolator and its circuit, and leave the site's detectors untouched.

Commercial lighting installation

Commercial Lighting Installation

from £65

Shops and offices run on a fire alarm panel rather than Aico domestic alarms. In a mixed building with a flat upstairs, the Aico alarms in the flat keep their own circuit live while we change the lighting below.

Starlink installation

Starlink installation

from £350

A Starlink job has no Aico part. Where the dish cable comes through the loft, we keep the drill and the new cable away from the alarm cable and the ceiling where the Aico bases are fixed.

Light switch or dimmer replacement

Light switch or dimmer replacement

from £60

Where the Aico alarms share the lighting circuit, they run on their backup cells while that breaker is off for the switch change. When the breaker goes back on, we check the green mains light on each alarm before we leave.

Minor works certificate

Minor works certificate

from £95

Adding an Aico alarm to an existing circuit is a small alteration. We test that circuit, then write the new alarm's position, the breaker protecting it and the test readings on the minor works certificate.

Extractor fan installation

Extractor fan installation

from £180

Steam drifting out of a bathroom can set off an optical Aico alarm on the landing. A fan that clears the steam stops those false alarms. We wire and test the fan, and the landing alarm stays where it is.

Electric shower installation

Electric shower installation

from £220

The shower runs on its own heavy circuit with no Aico part on it. We size the shower cable and check the main fuse can carry it. The alarm circuit keeps its own breaker on the board, apart from the shower.

Emergency lighting test & certificate

Emergency lighting test & certificate

from £150

Aico alarms have no part in an emergency lighting test. We switch off the mains feed to the escape lights, watch how long each one runs on its battery, and write a pass or fail for each fitting on the certificate.

Immersion heater repair

Immersion heater repair

from £70 an hour

An immersion repair touches no Aico alarm. We isolate only the immersion circuit, test the element and thermostat, and replace the failed part. The alarm circuit stays live the whole time.

Battery storage installation

Battery storage installation

from £4,500

When a home battery and inverter go in a garage or loft, we fit an Aico heat alarm in that space and link it to the house alarms. A fault at the battery then sounds in every room, not only where the battery is.

Fire alarm system installation

Fire alarm system installation

from £1,400

A building that needs a panel gets a fire alarm system with call points and sounders, not Aico alarms alone. Inside each flat of that building, Aico mains alarms can still protect the home, wired separately from the panel.

Cherry picker hire

Cherry picker hire

The cherry picker has no Aico part. From the platform we reach alarms on very high ceilings, such as a double height hall or stairwell, to test them, clean them or swap an expired head.

Do Aico alarms work when the house has no power?

  • No power in the whole houseYes. Aico mains alarms switch to their built in rechargeable cell, so they keep detecting while the house is dark, and the green light on each head goes out until the mains returns. If the alarm circuit is what keeps tripping the board, we test it head by head.

Other brands we work on

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Follow your job from booking to receipt

See when we're on our way, get your job report the moment we finish, and pay in seconds.

  • Track us on our way

    See us on the map with a live arrival time.

  • Your job report, same day

    See exactly what was done as soon as we finish.

  • Invoice and receipt in one place

    Pay online in seconds, and your receipt is always there when you need it.

Why choose Lighting Electrical

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

Aico alarm questions

Still have a question?

Do Aico alarms need their batteries changing?

No. The backup cell is sealed inside the alarm and lasts its whole working life. When the replace by date on the side arrives, we swap the head on the existing base.

Can you add an Aico alarm without running cable between rooms?

Yes. Each Aico mains alarm still needs a mains feed, but an Ei3000MRF RadioLINK+ module links it to the other alarms by radio. That means no interconnect cable has to cross the ceilings between rooms.

Which Aico alarm should go in a kitchen?

An Ei3014 heat alarm. It responds to a rapid rise in temperature, so toast and frying do not set it off the way they set off a smoke alarm. It links to the other heads, so a kitchen fire sounds through the house.

Why is there a yellow light on my Aico alarm?

A yellow light means the alarm has found a fault in itself. The flash pattern shows whether the sensor, the backup cell or the alarm's working life has failed. We read it, and in most cases replace the head on its existing base.

Can you replace another make of smoke alarm with Aico?

Yes. We fit Aico bases over the existing wiring and change every head in the linked set at once, because different makes do not sound together. Then we test that each alarm sets off all the others.