Wylex consumer units in Peterborough
Lighting Electrical works on Wylex consumer units in Peterborough, from old rewirable fuse boards to metal units with RCD protection, and leaves every circuit on the board tested and clearly marked.
Calls answered 24/7
- 10 years trading
Wylex consumer units we fit and repair
We fit new Wylex consumer units and repair older Wylex boards, including rewirable fuse boards. A consumer unit is the box of breakers where every circuit starts. Its ways are the slots those breakers fill.
- Rewirable Wylex fuse boardsOlder Wylex boards hold plug in fuse carriers with fuse wire inside. They have no RCD, the device that cuts the power when current leaks to earth. We replace these boards and move each circuit onto its own breaker.
- Modern Wylex consumer unitsWe fit Wylex metal consumer units with dual RCD protection or RCBOs. An RCBO is a breaker with its own earth leakage protection. With RCBOs, one fault trips one circuit instead of half the house.
- Faults we fix on Wylex boardsA consumer unit shows no fault codes. The faults we fix are RCDs that trip and will not reset, breakers that drop under load, loose terminals and heat marks on fuse carriers or the busbar. The busbar is the metal bar that feeds each breaker.
- What servicing a Wylex board involvesA board has no moving parts to service. We tighten the terminals, time each RCD trip with a tester, check the insulation on every circuit and update the labels. Between visits, press each RCD test button every three months.
What each service means for a Wylex board
EICR
from £150
An EICR, the electrical safety report, includes the Wylex board itself. We inspect the enclosure, the busbar and every breaker or fuse carrier, time each RCD trip and code anything that falls short.
Wylex consumer unit replacement
from £450
The old Wylex fuse board comes out and a new consumer unit goes in, either Wylex or another make you choose. Each circuit lands on a marked breaker with RCD or RCBO protection and is tested before the power goes back on.
House rewiring
from £2,400
A rewire finishes at the consumer unit. A modern Wylex unit that tests well can stay and take the new circuits on its spare ways. An old rewirable Wylex board is replaced.
Electrical fault finding
from £75 an hour
Fault finding starts at the Wylex board. We note which breaker or RCD dropped, isolate that circuit and test along it until we find the failed joint, accessory or cable.
Lighting installation
from £65
New lights run from a lighting circuit that leaves the Wylex board. We check that circuit is protected and labelled correctly. A new lighting circuit gets its own breaker in a spare way.
EV charger installation
from £750
A chargepoint needs a dedicated circuit, so we check the Wylex board for a spare way and the right RCD type. If the board is full, changing it is priced as a separate line.
Socket installation
from £85
Extra sockets join a circuit fed from the Wylex board. We check the breaker rating and RCD cover on that circuit before adding a point. A kitchen or outdoor socket that has no RCD protection gets it.
Emergency electrician
from £90 an hour
Out of hours, the Wylex board is the first place we look. If a main switch or RCD will not reset, we isolate the faulty circuit so the rest of the house can come back on.
Electrical testing and certificates
from £95
PAT testing covers plug in appliances, not the Wylex board. We test each portable appliance and record a pass or fail. The board itself is checked under an EICR instead.
Smoke alarm installation
from £110
Mains smoke and heat alarms take their power from a circuit on the Wylex board. We wire them to their own way or to a lighting circuit that gets regular use, so a dead alarm circuit gets noticed quickly.
Appliance and heating connections
from £120
A cooker or oven needs a circuit rated for its load. Before we connect it, we check that the breaker or fuse on the Wylex board matches both the cable and the appliance.
Solar panel and battery storage installation
from £5,500
Solar generation feeds into the house through the consumer unit. If the Wylex board has a suitable spare way, the inverter circuit lands there. If it does not, we fit a dedicated board for the panels and battery.
Forklift charger installation
from £700
Forklift chargers sit in commercial premises fed from a distribution board, not a domestic Wylex unit. We fit the charger on its own circuit and isolator, fed from the board that serves the bay.
Commercial Lighting Installation
from £65
Shop and office lighting is fed from the main board in the premises. Where that board is a Wylex unit, we check each lighting breaker can carry the new fittings and mark every way clearly.
Starlink installation
from £350
A Starlink dish runs from an ordinary socket, so most jobs leave the Wylex board alone. We mount the dish, run the cable and set up the router. If a new socket circuit is needed, it takes a spare way.
Light switch or dimmer replacement
from £60
Changing a switch or dimmer starts with switching off the lighting breaker on the Wylex board. We prove the circuit is dead, swap the control and check the lights work from it.
Minor works certificate
from £95
A minor works certificate names the Wylex breaker or fuse that protects the altered circuit. We test that circuit and write the device type and rating on the form.
Extractor fan installation
from £180
An extractor fan takes its power from the lighting circuit or from a fused spur, which is a switched outlet with its own fuse. We isolate that circuit at the Wylex board, fit the fan and test the circuit once the fan runs.
Electric shower installation
from £220
An electric shower draws a heavy current and needs its own circuit. We check the Wylex board has a spare way with RCD protection, and we size the cable to the shower's kW rating.
Emergency lighting test & certificate
from £150
Emergency lighting is a workplace and shared hall job rather than a home Wylex board job. We isolate the circuit feeding the emergency fittings, watch each lamp run on battery and certify the result.
Immersion heater repair
from £70 an hour
An immersion that trips the board is often leaking current through a failed element. We isolate its circuit at the Wylex board, test the element and thermostat, and replace whichever has failed.
Battery storage installation
from £4,500
A battery joins the installation at the consumer unit. We check that the Wylex board, the earthing and the bonding can take the extra load before we connect the battery.
Fire alarm system installation
from £1,400
A fire alarm panel needs a dedicated supply that nobody can switch off by mistake. We give it its own labelled breaker, on a Wylex unit or on a commercial distribution board.
Cherry picker hire
Cherry picker hire involves no Wylex equipment. We bring the machine, set it up on firm ground and operate it for jobs at height such as floodlights and signs.
Power problems traced to a Wylex board
- No power in the whole houseCheck the main switch and each RCD on the Wylex board first. If they are all on and the street is dark too, call the network operator. If the main switch will not stay up, we find the circuit that keeps tripping it.
Other brands we work on
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Follow your job from booking to receipt
See when we're on our way, get your job report the moment we finish, and pay in seconds.
Track us on our way
See us on the map with a live arrival time.
Your job report, same day
See exactly what was done as soon as we finish.
Invoice and receipt in one place
Pay online in seconds, and your receipt is always there when you need it.
Why choose Lighting Electrical
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowShould I replace my old Wylex fuse board?
Age alone is not a reason to replace it. A rewirable Wylex board has no RCD protection, and that missing protection is the main reason to change it. We test the earthing, bonding and circuits first, then say plainly whether it needs replacing.
Can you fit a new Wylex consumer unit in place of my old one?
Yes, if you want to stay with Wylex. The new unit gets RCD or RCBO protection to suit your circuits. Every way is marked and tested before the power goes back on.
Are Wylex plug in breakers safe to keep in an old fuse board?
They replace fuse wire with a breaker you can reset, but they add no RCD protection. We check the carriers and terminals for heat damage. An EICR records whether the board still needs changing.
Why does the RCD on my Wylex board keep tripping?
An RCD trips when current leaks to earth. Common causes are a damp outdoor fitting, a failing appliance or a damaged cable. We split the circuits on that RCD and test each one until the readings show the cause.
Do I get a certificate when my consumer unit is changed?
Yes. Changing a consumer unit is notifiable work. It is certified and notified through our NAPIT registration, and you keep the certificate with the test results for every circuit.