myenergi EV chargers in Peterborough
Lighting Electrical fits and repairs myenergi zappi EV chargers in Peterborough, leaving each charger on its own tested circuit and set to charge the car from spare solar power where the house has panels.
Calls answered 24/7
- 10 years trading
Which myenergi chargers do we fit and repair?
myenergi makes the zappi, a home EV charger that can fill the car from the grid or from spare solar power. We fit new zappi units, move existing ones and trace faults on them.
- zappi chargers, tethered and untetheredWe fit the zappi in tethered form, with the lead fixed to the unit, or untethered, with a socket for your own cable. Most homes take the 7kW single phase model. The 22kW model needs a three phase supply, which we check before anything is ordered.
- CT clamps, harvi and the myenergi hubA CT clamp is a clip on sensor around the meter tail that tells the zappi how much power the house imports or exports. Where the meter is too far away for a cable, a harvi sends that reading wirelessly. The hub plugs into your router for the app and firmware updates.
- zappi faults and screen messages we fixWe fix PEN faults, where the zappi has switched off because the supply voltage left its safe band. We also fix earth leakage trips, a charger stuck waiting for surplus because a CT clamp faces the wrong way, and a hub that has lost its link to the app.
- What servicing a zappi involvesWe tighten the terminals, check the cable gland and casing seals, and test the earth leakage protection at the charger. Then we check the CT readings match the meter and that the firmware is current in the myenergi app.
What we do on a zappi in each service
EICR
from £150
An EICR, the electrical safety report, covers the zappi circuit like any other circuit in the house. We test the cable, the breaker feeding it and the earth at the charger, and note whether the earthing at the charger suits the supply type.
Consumer unit replacement
from £450
A new consumer unit, the box of breakers, gives the zappi its own RCBO, a breaker with earth leakage protection built in. The CT clamp on the meter tail is refitted facing the right way, or the zappi reads import as export.
House rewiring
from £2,400
A rewire is the easiest time to lay a dedicated cable from the consumer unit to where a zappi will go, even if the charger comes later. An existing zappi circuit that tests sound is reconnected to the new board.
Electrical fault finding
from £75 an hour
When a zappi stops charging, we read the message on its screen, check its breaker at the board and measure the supply at the charger. We also check the CT clamp, since a loose or reversed clamp can leave the charger waiting for surplus that never comes.
Lighting installation
from £65
Lighting work does not touch the zappi. Where you want a driveway light beside the charger, we fit it on a lighting circuit and never on the charger's dedicated cable.
myenergi EV charger installation
from £750
We mount the zappi at the parking spot on its own circuit, clip the CT clamp to the meter tail and pair the charger with the myenergi app. We set Eco, Eco+ or Fast mode with you, then test the charger and leave the certificate.
Socket installation
from £85
A zappi is wired in, so it needs no socket. If you want an outdoor socket near it for a jet washer or garden tools, we fit a weatherproof one on a separate protected circuit.
Emergency electrician
from £90 an hour
Out of hours, a zappi that has tripped the board or shows heat damage is switched off at its breaker and local isolator. The rest of the house goes back on, and the charger stays off until it has been tested.
Electrical testing and certificates
from £95
PAT testing covers plug in appliances, so a wired in zappi is not part of it. A portable three pin charging lead you used before the zappi arrived can be tested and recorded on the PAT certificate.
Smoke alarm installation
from £110
Smoke and heat alarms do not connect to a zappi. Where the charger sits in an integral garage, we fit a heat alarm there rather than a smoke alarm, so dust does not set it off.
Appliance and heating connections
from £120
A cooker or electric heater and a zappi on full power both draw heavy current. Before we connect a new appliance, we check the incoming supply can carry it while the car is charging.
Solar panel and battery storage installation
from £5,500
Solar panels let the zappi charge from spare generation. We place the CT clamps so the charger sees what the panels export, then set Eco+ mode so the car fills from that surplus before power goes back to the grid.
Forklift charger installation
from £700
Forklift chargers are industrial units, not myenergi products. We fit them on their own circuit and isolator, and a zappi for staff cars on the same site stays on a separate circuit.
Commercial Lighting Installation
from £65
Commercial lighting does not involve a zappi. Where a workplace has zappi bays, we keep the car park lighting on its own circuit and check the distribution board can carry both loads.
Starlink installation
from £350
The myenergi hub plugs into your router by cable. If the Starlink router goes in a new spot, we make sure the hub still has a cable to it, so the zappi app and firmware updates keep working.
Light switch or dimmer replacement
from £60
Changing a switch or dimmer does not touch the zappi. We isolate only the lighting circuit, so the charger keeps working while the new control goes in.
Minor works certificate
from £95
Moving or extending an existing zappi circuit is a minor alteration. The minor works certificate records the circuit, the breaker protecting it and the test results taken at the charger.
Extractor fan installation
from £180
Extractor fans have no link to a zappi. We fit the fan on the lighting circuit or a fused spur, a switched outlet with its own fuse, and leave the charger circuit alone.
Electric shower installation
from £220
An electric shower and a zappi running together pull a heavy load. We check the main fuse can carry both, and we can set the zappi to limit the current it takes from the supply.
Emergency lighting test & certificate
from £150
Emergency lighting has no link to a zappi. We test the emergency fittings by cutting their mains feed, while any zappi bays in the car park stay live on their own circuits.
Immersion heater repair
from £70 an hour
A zappi does not heat water. We repair the immersion element, thermostat or wiring, and the zappi on its own circuit carries on charging through the work.
Battery storage installation
from £4,500
A home battery and a zappi both read the grid through CT clamps. We place each clamp so the battery does not empty itself into the car unless you choose that.
Fire alarm system installation
from £1,400
Fire alarm systems have no link to a zappi. We feed the panel from its own labelled breaker, and in a building with charging bays the panel stays on a circuit apart from the chargers.
Cherry picker hire
Cherry picker hire involves no zappi. We bring the machine and operate it for work at height, such as lights above a car park with charging bays.
Can a zappi fault cut power to the whole house?
- No power in the whole houseOn older boards where one RCD covers several circuits, a leak at the zappi can switch off the whole house. We check the main switch and the street first, then isolate the charger circuit and test it.
Other brands we work on
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Follow your job from booking to receipt
See when we're on our way, get your job report the moment we finish, and pay in seconds.
Track us on our way
See us on the map with a live arrival time.
Your job report, same day
See exactly what was done as soon as we finish.
Invoice and receipt in one place
Pay online in seconds, and your receipt is always there when you need it.
Why choose Lighting Electrical
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowCan a zappi charge my car from my solar panels?
Yes. In Eco or Eco+ mode the zappi uses the surplus the CT clamp measures, so the car takes power that would otherwise go back to the grid. Fast mode charges at full rate from the grid whatever the panels are doing.
Do I need an earth rod for a zappi?
Usually not. The zappi has PEN fault protection built in, which switches off charging if the combined neutral and earth in the supply cable fails. We check the earthing arrangement at the meter before fitting.
What does a PEN fault message on my zappi mean?
The zappi has seen the supply voltage move outside its safe band and has stopped charging. A loose neutral or low voltage at busy times can cause it. We measure at the meter and at the charger to find which.
Can you move my zappi to a different wall?
Yes. We take the charger down, run new cable to the new position and refit it. The circuit is tested again and the CT clamp is checked before the charger goes back into use.
My meter is a long way from the charger. Can a zappi still use solar?
Yes. A harvi clips around the meter tail and sends the reading to the zappi wirelessly, so no cable is needed between them. We pair it during the visit and check the readings match the meter.