FireAngel

FireAngel smoke and heat alarms in Peterborough

Lighting Electrical fits and replaces FireAngel smoke and heat alarms in Peterborough. Mains alarms are linked so that one sounding sets off every alarm in the home.

Calls answered 24/7

  • 10 years trading

Which FireAngel alarms do you fit and repair?

We fit FireAngel mains and sealed battery alarms, link them together and repair the ones already on your ceilings. Interlinked means the alarms are joined by cable or radio, so one alarm sounding sets off the rest.

  • FireAngel mains smoke and heat alarmsFireAngel Pro Connected alarms run on mains power and keep a sealed backup battery for power cuts. Each one takes a feed from a circuit at the consumer unit, the box of breakers. The alarms are linked by an interlink cable between them or by FireAngel radio modules where cable cannot reach.
  • FireAngel sealed battery alarmsThese alarms hold a lithium battery sealed inside for the life of the unit, so they need no mains cable. An optical smoke alarm goes in the hall and on each landing. A heat alarm goes in the kitchen, where cooking would set off a smoke alarm.
  • Chirps, flashing lights and false alarmsFireAngel alarms show no number codes. Faults appear as a chirp and a light pattern, which the leaflet for each model explains. We fix chirps from a failing backup battery or an alarm at the end of its life, false alarms from dust or steam, and links where one alarm no longer sets off the others.
  • What servicing a FireAngel alarm involvesWe press the test button on every alarm and sound one alarm to check the others follow. We clear dust from the vents and read the expiry date printed on the side of each alarm. The battery is sealed in and cannot be changed, so an alarm past its date is replaced as a whole unit.

FireAngel’s website

What happens to FireAngel alarms in each electrical job?

EICR testing in Peterborough

EICR

from £150

An EICR covers the circuit feeding mains FireAngel alarms: its breaker, its cable and its earth. A fault on that circuit is coded on the report the same way as a fault on any other circuit in the property.

Fuse board replacement

Consumer unit replacement

from £450

When the consumer unit changes, the FireAngel alarm circuit moves onto a new breaker in the new board. Once the power is back, we check that every mains alarm shows its power light again.

House rewiring in Peterborough

House rewiring

from £2,400

A rewire is the easiest time to run a fresh feed and interlink cable to every alarm position. New FireAngel mains alarms go up near the end, once the new circuits have passed their tests.

Electrical fault finding

Electrical fault finding

from £75 an hour

If a FireAngel alarm chirps while it has mains power, or its circuit keeps tripping, we test the circuit before we touch the alarm. The readings show whether the cable, a loose joint or the alarm itself is at fault.

Lighting installation

Lighting installation

from £65

Mains FireAngel alarms often take their power from a lighting circuit. When new lights go on that circuit, the alarm feed stays connected, and we check each alarm has power before we leave.

EV charger installation

EV charger installation

from £750

A charge point has no FireAngel parts. We fit the charger on its own circuit. If you also book alarm work, a FireAngel heat alarm can go in an attached garage, where exhaust fumes would set off a smoke alarm.

Socket and switch installation

Socket installation

from £85

Socket work uses no FireAngel equipment. We switch off only the circuit we are working on, fit and test the new points, and leave the alarm circuit alone.

Emergency electrician

Emergency electrician

from £90 an hour

Out of hours, we isolate the circuit of a FireAngel alarm that will not stop sounding, or that smells of burning at its base. A replacement alarm follows once the cause is found.

Electrical testing and certificates

Electrical testing and certificates

from £95

PAT testing covers appliances with a plug, so ceiling mounted FireAngel alarms fall outside it. We test each portable appliance and record whether it passes or fails.

Fire and smoke alarm installation

FireAngel smoke alarm installation

from £110

This is the main FireAngel job. We fit an optical smoke alarm on each storey and a heat alarm in the kitchen, using mains or sealed battery models. Then we link the alarms and sound each one to check the rest respond.

Appliance and heating connections

Appliance and heating connections

from £120

A cooker connection uses no FireAngel parts. If a smoke alarm sits close to the new hob, we tell you that a FireAngel heat alarm suits that spot better.

Solar and battery storage

Solar panel and battery storage installation

from £5,500

Solar work involves no FireAngel equipment. We fit the panels, the inverter and the isolation. The circuit for any mains alarms is left out of the isolation while the connections are made.

Forklift charger installation

Forklift charger installation

from £700

Forklift chargers are warehouse plant with no FireAngel parts. We fit the charger, its isolator and the circuit for the bay, then test the installation.

Commercial lighting installation

Commercial Lighting Installation

from £65

Shop and office lighting uses no FireAngel alarms. We fit the fittings and their switching. Premises that need linked detection across the building are quoted for a fire alarm system instead.

Starlink installation

Starlink installation

from £350

A Starlink job uses no FireAngel equipment. We mount the dish, seal the cable entry and set up the router so the connection works.

Light switch or dimmer replacement

Light switch or dimmer replacement

from £60

Changing a switch means switching off the lighting circuit, and mains FireAngel alarms on that circuit move onto their backup battery. Once the new switch is in, we check every alarm shows its power light again.

Minor works certificate

Minor works certificate

from £95

Adding a mains FireAngel alarm to an existing lighting circuit counts as a small alteration. The minor works certificate records that circuit, the breaker protecting it and the test readings.

Extractor fan installation

Extractor fan installation

from £180

A FireAngel smoke alarm near a bathroom door can go off from shower steam. A working extractor fan clears that steam. The fan itself is wired with no alarm parts.

Electric shower installation

Electric shower installation

from £220

An electric shower involves no FireAngel equipment. We fit the unit, connect it to a circuit rated for its load with an isolation switch, and test the circuit.

Emergency lighting test & certificate

Emergency lighting test & certificate

from £150

Emergency lighting is a separate system from FireAngel alarms. We cut the mains feed to the emergency fittings, time each battery and certify the result.

Immersion heater repair

Immersion heater repair

from £70 an hour

An immersion repair uses no FireAngel parts. We isolate the immersion circuit, test the element and thermostat, and replace whichever one has failed.

Battery storage installation

Battery storage installation

from £4,500

A home battery involves no FireAngel equipment. We mount the unit, connect it to the installation, then test it before the circuits come back on.

Fire alarm system installation

Fire alarm system installation

from £1,400

A panel system uses commercial detectors, call points and sounders, not FireAngel domestic alarms. Where a building has outgrown linked FireAngel alarms, we fit a panel system instead.

Cherry picker hire

Cherry picker hire

Cherry picker hire uses no FireAngel parts. The platform can reach an alarm on a stairwell or atrium ceiling that is too high for a ladder.

Do FireAngel alarms work in a power cut?

  • No power in the whole houseYes. A mains FireAngel alarm switches to its sealed backup battery when the house loses power, so it still sounds in a fire. Once we have found why the power dropped and restored it, we check that each alarm shows its power light again.

Other brands we work on

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Follow your job from booking to receipt

See when we're on our way, get your job report the moment we finish, and pay in seconds.

  • Track us on our way

    See us on the map with a live arrival time.

  • Your job report, same day

    See exactly what was done as soon as we finish.

  • Invoice and receipt in one place

    Pay online in seconds, and your receipt is always there when you need it.

Why choose Lighting Electrical

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

FireAngel smoke alarm questions

Still have a question?

Can you link my FireAngel alarms so they all go off together?

Yes. Mains alarms are linked by an interlink cable between them, or by FireAngel radio modules where a cable cannot reach. We sound one alarm to check that every other alarm in the home follows.

Should I have mains or sealed battery FireAngel alarms?

Mains alarms run from a circuit at the board and keep a backup battery for power cuts. Sealed battery alarms need no cable, so the ceilings stay untouched. We look at the property and tell you which suits each room.

Why does my FireAngel alarm keep chirping?

A chirp with a flashing light usually means a weak backup battery or an alarm that has reached the end of its life. The light pattern shows which, and the leaflet for that model explains the pattern. An alarm past its expiry date is replaced, because its battery is sealed in.

How many FireAngel alarms does a rented home need?

A rented home in England needs a working smoke alarm on each storey used as living accommodation. We fit a FireAngel smoke alarm on each of those storeys and a heat alarm in the kitchen. You keep the paperwork for the tenancy file.

When does a FireAngel alarm need replacing?

Each alarm has an expiry date printed on its side. When that date passes, the whole alarm is replaced, because the battery cannot be changed. We read the dates on every alarm and replace any that have run out.

Book or ask a question

Calls answered 24/7